During a breaking operation of charging current with a disconnecting switch (DS) in SF6 gas-insulated switchgear (GIS), the occurrence of a fault to ground from the DS co...Show MoreMetadata
Abstract:
During a breaking operation of charging current with a disconnecting switch (DS) in SF6 gas-insulated switchgear (GIS), the occurrence of a fault to ground from the DS contact by a restriking surge was reported to be observed. The flashover voltage in this case, is appreciably lower than the normal withstand voltage to the ground. It has been clarified through high-speed photography with an image converter camera that the flashover is caused by a streamer generated during restriking between the DS contacts. In this respect, with the objective of confirming these phenomena in a simulated power system, two synthetic test circuits were constructed by using 550kV DS's. Verification tests were carried out to confirm the equivalence between these two test circuits. The DS's subjected to test withstood a surge voltage of 2.3pu-the maximum voltage obtained by simulating calculations of various GIS configurations.
Published in: IEEE Transactions on Power Apparatus and Systems ( Volume: PAS-102, Issue: 1, January 1983)
Cause of Arcing inside a Medium Voltage Arc-Resistant Metal-clad Switchgear Compartment on a sunny day without any Evidence of Switching Surge
Dev Paul,Kor Yan
High Current Interruption by SF6 Disconnecting Switches in Gas Insulated Switchgear
S. Yanabu,S. Nishiwaki,H. Mizoguchi,N. Shimokawara,Y. Murayama
Evaluation of breakdown characteristics of gas insulated switchgears for non-standard lightning impulse waveforms - breakdown characteristics for non-standard lightning impulse waveforms associated with disconnector switching surges -
Shigemitsu Okabe,Sadayuki Yuasa,Shuhei Kaneko
Application of high voltage gradient zinc oxide elements to SF/sub 6/ gas insulated surge arresters for 22 kV-765 kV power systems
S. Shirakawa,I. Ejiri,S. Watahiki,N. Iimura,S. Nakano,S. Yamada,S. Kondo
Ground Fault by Restriking Surge of SF6 Gas-Insulated Disconnecting Switch and Its Synthetic Tests
S. Nishiwaki,Y. Kanno,S. Sato,E. Haginomori,S. Yamashita,S. Yanabu
Characteristic of large current making switch to verify making performance of high voltage switchgear
K. Suzuki,S. Nishiwaki,H. Kawano,K. Kudo,K. Miyazaki,N. Miyake,H. Ikeda
Ground Fault By Restriking Surge of SF6 Gas-Insulated Disconnecting Switch and Its Synthetic Tests
S. Nishiwaki,Y. Kanno,S. Sato,E. Haginomori,S. Yamashita,S. Yanabu
Interrupting Performance of Capacitive Current By Disconnecting Switch for Gas Insulated Switchgear
S. Narimatsu,K. Yamaguchi,S. Nakano,S. Maruyama