During a breaking operation of charging current with a disconnecting switch (DS) in SF6 gas-insulated switchgear (GIS), the occurrence of a fault to ground from the DS co...Show MoreMetadata
Abstract:
During a breaking operation of charging current with a disconnecting switch (DS) in SF6 gas-insulated switchgear (GIS), the occurrence of a fault to ground from the DS contact by a restriking surge was reported to be observed. The flashover voltage in this case, is appreciably lower than the normal withstand voltage to the ground. It has been clarified through high-speed photography with an image converter camera that the flashover is caused by a streamer generated during restriking between the DS contacts. In this respect, with the objective of confirming these phenomena in a simulated power system, two synthetic test circuits were constructed by using 550kV DS's. Verification tests were carried out to confirm the equivalence between these two test circuits. The DS's subjected to test withstood a surge voltage of 2.3pu-the maximum voltage obtained by simulating calculations of various GIS configurations.
Published in: IEEE Transactions on Power Apparatus and Systems ( Volume: PAS-102, Issue: 1, January 1983)
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Maximum Voltage ,
- Voltage Spikes ,
- Synthetic Test ,
- Synthetic Circuits ,
- Test Circuit ,
- Peak Value ,
- Time Constant ,
- Power Source ,
- Equivalent Circuit ,
- Gas Pressure ,
- Electric Field Strength ,
- Voltage Values ,
- DC Voltage ,
- Voltage Waveforms ,
- Resistance Rs ,
- Discharge Current ,
- Terminal Voltage ,
- Contact Distance ,
- Circuit Breaker ,
- Voltage Generator ,
- Impulse Propagation ,
- Peak Value Of Voltage ,
- Load Side ,
- Charging Voltage ,
- Voltage Divider ,
- Ground Fault ,
- Voltage Polarity ,
- Stray Capacitance ,
- Alternating Current
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Maximum Voltage ,
- Voltage Spikes ,
- Synthetic Test ,
- Synthetic Circuits ,
- Test Circuit ,
- Peak Value ,
- Time Constant ,
- Power Source ,
- Equivalent Circuit ,
- Gas Pressure ,
- Electric Field Strength ,
- Voltage Values ,
- DC Voltage ,
- Voltage Waveforms ,
- Resistance Rs ,
- Discharge Current ,
- Terminal Voltage ,
- Contact Distance ,
- Circuit Breaker ,
- Voltage Generator ,
- Impulse Propagation ,
- Peak Value Of Voltage ,
- Load Side ,
- Charging Voltage ,
- Voltage Divider ,
- Ground Fault ,
- Voltage Polarity ,
- Stray Capacitance ,
- Alternating Current