Incorporating Planar Folded Front Masses in Bolted Langevin-Style Transducers for Minimally Invasive Surgery | IEEE Conference Publication | IEEE Xplore

Incorporating Planar Folded Front Masses in Bolted Langevin-Style Transducers for Minimally Invasive Surgery


Abstract:

The Harmonic ACE® (J&J Medical Devices, OH, USA) based on the conventional Bolted-Langevin Transducer (BLT) configuration of piezoelectric transducers is used in robotic ...Show More

Abstract:

The Harmonic ACE® (J&J Medical Devices, OH, USA) based on the conventional Bolted-Langevin Transducer (BLT) configuration of piezoelectric transducers is used in robotic surgery due to its fast cutting of soft tissues and improved cut quality. However, the manoeuvrability of the Harmonic Aceh® which is the only ultrasonic scalpel compatible with the Da Vinci Surgical System® (Intuitive Surgical Inc., CA, USA) is very limited for the surgeon, due to its long shaft and tool-robot configuration. Till now, there is no existing ultrasonic scalpel compatible with the Da Vinci® Surgical System EndoWrist® instruments. Therefore, the key objective of this work is to create miniaturised ultrasonic instruments to allow greater dexterity than conventional tools. To address this, an alternative approach can be adopted which utilises a planar folded front mass incorporated within BLT configurations with the aim to reduce the overall length of the tool whilst maintaining the amplification gain. The introduction of planar folded (PF) and twice planar folded (TPF) front masses within BLT configurations and after being optimised using design of experiments (DOE) techniques, demonstrate high amplification gains, GA = 90 @ 23 kHz and GA = 92 @ 21 kHz, respectively, and transducer lengths of 58 mm (87% length reduction) and 64 mm (86% length reduction) compared with a 450 mm Harmonic ACE®.
Date of Conference: 11-16 September 2021
Date Added to IEEE Xplore: 12 November 2021
ISBN Information:

ISSN Information:

Conference Location: Xi'an, China

Funding Agency:

References is not available for this document.

I. Introduction

Ultrasonic power surgical instruments operating in the high power 10W/cm2 low-frequency range 20 - 60 kHz have recognised advantages, including high cut quality, fast and precise tissue cutting, less thermal damage and less bleeding [1]. With these motivations, many researchers are trying to develop ultrasonic scalpels that could interfaced with the Da Vinci® surgical system to combine the advantages of both instruments for robotic procedures. The Harmonic ACE® is the first ultrasonic actuated instrument that has been adapted with the Da Vinci® Surgical system for robotic surgery. Nevertheless, there is no existing power ultrasonic surgical instrument compatible with the Da Vinci® EndoWrist® instruments.

Select All
1.
B. J. O'Daly, E. Morris, G. P. Gavin, J. M. O'Byrne and G. B. McGuinness, "High-power low-frequency ultrasound: A review of tissue dissection and ablation in medicine and surgery", Journal of Materials Processing Technology, vol. 200, no. 1, pp. 38-58, 2008.
2.
M. Lucas and A. Mathieson, "Ultrasonic cutting for surgical applications" in Power Ultrasonics: Applications of High-Intensity Ultrasound, Elsevier Ltd., [online] Available: https://doi.org/10.1016/B978-1-78242-028-6.00023-5.
3.
R. Devassy, S. Hanif, H. Krentel, H. C. Verhoeven, L. A. T.l. Roche and R. L. D. Wilde, "Laparoscopic ultrasonic dissectors: technology update by a review of literature", Dovepress Medical Devices: Evidence and research, 2019.
4.
S. C. Yang, J. Ahn, J. H. Kim, J. W. Yi, M. H. Hur and K. Lee, "Compar-ison of the vessel sealer Extend with harmonic ACE in robotic bilateral axillary-breast approach thyroid surgery", Gland Surgery, vol. 9, no. 2, pp. 164-171, 2020.
5.
I. Khalaji, M. D. Naish and R. V. Patel, "Articulating Minimally Invasive Ultrasonic Tool for Robotics-Assisted Surgery", IEEE International Conference on Robotics and Automation (ICRA), pp. 573-578, May. 2015.
6.
J. Li, H. Liu, J. Li, Y. Yang and S. Wang, "Piezoelectric transducer design for an ultrasonic scalpel with enhanced dexterity for minimally invasive surgical robots", Proc IMechE Part C: J Mechanical Engineering Science, vol. 234, no. 7, pp. 1271-1285, 2020.
7.
S. Sherrit, S. A. Askins, M. Gradziol, B. P. Dolgin, X. Bao, Z. Chang, et al., "Novel horn designs for ultrasonic/sonic cleaning welding soldering cutting and drilling", Proc. SPIE 4701 Smart Structures and Materials 2002: Smart Structures and Integrated Systems, 2002.
8.
A. Mathieson, A. Cardoni, N. Cerisola and M. Lucas, "The Influence of Piezoceramic Stack Location on Nonlinear Behavior of Langevin Transducers", IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, vol. 60, no. 6, pp. 1126-1133, 2013.

Contact IEEE to Subscribe

References

References is not available for this document.