Loading [MathJax]/extensions/MathMenu.js
Simulation Investigation on Anti-DC Current Transformer with Double Core | IEEE Conference Publication | IEEE Xplore

Simulation Investigation on Anti-DC Current Transformer with Double Core


Abstract:

Effect of anti DC bias of current transformer is important for Measurement and protection. This paper proposes a simulation model of current trans-former with double core...Show More

Abstract:

Effect of anti DC bias of current transformer is important for Measurement and protection. This paper proposes a simulation model of current trans-former with double core based on simulink boxtool of matlab. The magnetization characteristics of air gap core is studied according to the Jiles- atherton theory. The effect of anti DC bias of current transformer with double core is also analyzed.
Date of Conference: 28-30 May 2021
Date Added to IEEE Xplore: 17 August 2021
ISBN Information:
Conference Location: Wuhan, China
References is not available for this document.

I. Introduction

Current transformer is the basic component of measurement and protection in power system, its accuracy and reliability affect the stable operation of power grid [1]-[4]. Due to the geomagnetic field, DC power transmission, high-power power electronic devices and other factors, the DC component and harmonic component in power system are increasing. When the DC component appears in the current transformer winding, the DC flux is generated in the core magnetic circuit, which leads to the DC bias [5]-[8], resulting in a significant increase in the error of the current transformer and affecting the subsequent measurement and protection devices. Therefore, it is necessary to study the current transformer with strong resistance to DC bias to ensure the stability of power system.

Select All
1.
LI Hongbin, ZHANG Mingming, LIU Yanbing et al., "Study and comparison on several different types of electronic current transformers [J]", High Voltage Engineering, vol. 30, no. 1, pp. 4-5, 2004.
2.
Daisuke Miyagi, Tsutomu Yoshida, Masanori Nakano et al., "Development of measuring equipment of DC-biased magnetic properties using open-type single-sheet tester [J]", IEEE Transactions on Magnetics, vol. 42, no. 10, pp. 2846-2848, 2006.
3.
Andrew C. Corney, "Simple absolute method for current transformer calibration[J]", IEEE Transactions on Instrumentation and Measurement, vol. 50, no. 2, pp. 278-281, 2001.
4.
U D Annakkage, P G McLaren, E Dirks et al., "A current transformer model based on the Jiles-Atherton theory of ferromagnetic hysteresis[J]", IEEE Transactions on Power Delivery, vol. 15, no. 1, pp. 57-61, 2000.
5.
Shu Lu and Yilu Liu, "FEM analysis of DC saturation to assess transformer susceptibility to geomagnetically induced currents [J]", IEEE Transactions on Power Delivery, vol. 8, no. 3, pp. 1367-1376, 1993.
6.
Mao Anlan, Wang Huan, Wang Xiaoqi et al., "Research on performance of current transformer affected by DC bias[J]", Electrical Measurement & Instrumentation, vol. 50, no. 10, pp. 69-72, 2013.
7.
Tan Bingyuan, Lu Jiping, Jiang Bo et al., "Analysis of influence of DC bias on instrument current transformer [J]", Power System Technology, vol. 38, no. 5, pp. 1408-1413, 2014.
8.
Wang Baoshuai, Xiao Xia, Xu Yan et al., "Research on test system of a novel anti-DC current transformer [J]", Power System Protection and Control, vol. 46, no. 17, pp. 77-83, 2018.
9.
XIAO Yaorong, "Prove the transient characteristics of current transformer with air-gapped core [J]", Transformer, no. 4, pp. 8-12, 1980.
10.
ZHANG Guixin, WAN Xiong and WANG Peng, "Electronic current transformer with non-magnetic air gap in core [J]", High Voltage Engineering, vol. 35, no. 9, pp. 2144-2149, 2009.
11.
Yang Peng, Zhao Wei, Huang Songling et al., "New study on the principle of air gapped core current transformer[J]", Electrical Measurement & Instrumentation, vol. 44, no. 10, pp. 44-47, 2007.
12.
Huang Shize and Guo Qiyi, "Simulation of transient characteristics for air gapped core current transformer[J]", Journal of System Simulation, vol. 23, no. 8, pp. 1719-1723, 2011.
13.
Chen Bin, Li Shisong, Lu Xin et al., "An analytical model of air-gap-core current transformer considering loading effect [J]", Electrical Measurement & Instrumentation, vol. 51, no. 23, pp. 1-5, 2014.
14.
Zhang Zhi and Wang Pingxin, "Analysis of the air-gap influence on iron core clamp-shape current transformers [J]", Smart Grid, no. 5, pp. 433-436, 2015.
15.
Li Zhixin, Wang Shaohua, Xu Minrui et al., "Design and performance analysis of a new type of wide range current transformer [J]", Electrotechnical Application, no. 13, pp. 36-39, 2017.
16.
Jin Shaoping, Li Min, Liu Jian et al., "Research on Low Anti-DC Current Transformer and its Detection Device[J]", Electrical Measurement & Instrumentation, vol. 53, no. 13, pp. 59-64, 2016.
17.
David C Jiles, J B Thoelke and M K Devine, "Numerical Determination of Hysteresis Parameters for the Modeling of Magnetic properties using the Theory of ferromagnetic Hysteresis[J]", IEEE Transactions on Magnetics, vol. 28, no. 1, pp. 27-35, 1992.
18.
U D Annakkage and P G Mclanren, "A Current Transformer Model Based on the Jiles-Atherton Theory of Ferromagnetic Hysteresis [J]", IEEE Trans. Magn., vol. 15, no. 1, pp. 57-62, 2000.
19.
S T Liu, S R Huang and HW. Chen, "Using TACS Functions Within EMTP to Set Up Current-Transformer Model Based on the Jiles-Atherton Theory of Ferromagnetic Hysteresis [J]", IEEE Transactions on Power Delivery, vol. 22, no. 4, pp. 2222-2227, 2007.
20.
D C Jiles and JB. Thoelke, "Theory of ferromagnetic hysteresis: determination of model parameters from experimental hysteresis loops [J]", IEEE Transactions on Magnetics, vol. 25, no. 5, pp. 3928-3930, 1989.