Loading [MathJax]/extensions/MathZoom.js
Simulation Investigation on Anti-DC Current Transformer with Double Core | IEEE Conference Publication | IEEE Xplore

Simulation Investigation on Anti-DC Current Transformer with Double Core


Abstract:

Effect of anti DC bias of current transformer is important for Measurement and protection. This paper proposes a simulation model of current trans-former with double core...Show More

Abstract:

Effect of anti DC bias of current transformer is important for Measurement and protection. This paper proposes a simulation model of current trans-former with double core based on simulink boxtool of matlab. The magnetization characteristics of air gap core is studied according to the Jiles- atherton theory. The effect of anti DC bias of current transformer with double core is also analyzed.
Date of Conference: 28-30 May 2021
Date Added to IEEE Xplore: 17 August 2021
ISBN Information:
Conference Location: Wuhan, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
R & D Center, Wuhan Pandian Science and Technology Co., Ltd, Wuhan, China
School of Electrical and Electronic Engineering, Hubei University of Technology, Beijing, China

I. Introduction

Current transformer is the basic component of measurement and protection in power system, its accuracy and reliability affect the stable operation of power grid [1]-[4]. Due to the geomagnetic field, DC power transmission, high-power power electronic devices and other factors, the DC component and harmonic component in power system are increasing. When the DC component appears in the current transformer winding, the DC flux is generated in the core magnetic circuit, which leads to the DC bias [5]-[8], resulting in a significant increase in the error of the current transformer and affecting the subsequent measurement and protection devices. Therefore, it is necessary to study the current transformer with strong resistance to DC bias to ensure the stability of power system.

Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
Departmemt of Metrology of Electric, Key Laboratory of CSG for Electric Power Measurement, Power Research Institute of Yunnan Power Grid Co. Ltd, Kunming, China
R & D Center, Wuhan Pandian Science and Technology Co., Ltd, Wuhan, China
School of Electrical and Electronic Engineering, Hubei University of Technology, Beijing, China
Contact IEEE to Subscribe

References

References is not available for this document.