Rotating Rectifier Failure Detection for Brushless Synchronous Starter/Generator in the Generator Mode | IEEE Conference Publication | IEEE Xplore

Rotating Rectifier Failure Detection for Brushless Synchronous Starter/Generator in the Generator Mode


Abstract:

A novel failure detection method for rotating rectifier of the brushless synchronous starter/generator in the generator mode has been proposed. In this method, the termin...Show More

Abstract:

A novel failure detection method for rotating rectifier of the brushless synchronous starter/generator in the generator mode has been proposed. In this method, the terminal voltage of the idle field winding of the main exciter is used. Firstly, the first maximum voltage and corresponding position in the voltage sample sequence are obtained. On this basis, the voltage sample sequence is reconstructed into two sequences to acquire the second maximum voltage. Then the voltage ratio is calculated for failure detection. Experimental results verify the feasibility and effectiveness of the proposed method.
Date of Conference: 18-21 October 2020
Date Added to IEEE Xplore: 18 November 2020
ISBN Information:

ISSN Information:

Conference Location: Singapore

Funding Agency:

References is not available for this document.

I. Introduction

The rapid development of the more electric aircraft has drawn great demand on the integrated starter/generator. In this case, the brushless synchronous starter/generator (BSSG) has become research focus for its mature generator technique together with large-scale application on board. As shown in Fig. 1, the BSSG consists of the pre-exciter (PE), the main exciter (ME), the rotating rectifier and the main machine (MM). The PE is a permanent magnet synchronous machine and the ME is a rotating-armature electrically excited generator with three-phase field windings. The rotating rectifier, mounted on the rotor shaft, is a three-phase full bridge diode rectifier, and a wound-rotor synchronous machine serves as the MM.

Select All
1.
T. D. Batzel and D. C. Swanson, "Prognostic Health Management of Aircraft Power Generators", IEEE Transactions on Aerospace and Electronic Systems, vol. 45, no. 2, pp. 473-482, 2009.
2.
Z. Zhang, W. Liu, J. Peng, D. Zhao, T. Meng, J. Pang, et al., "Identification of TBAES rotating diode failure", IET Electric Power Applications, vol. 11, pp. 260-271, Feb. 2017.
3.
N. Jiao, X. Han, Z. Wei, C. Sun, P. Liang and W. Liu, "On-Line Fault Diagnosis for Rotating Rectifier in Wound-Rotor Synchronous Starter-Generator Based on Geometric Features of Current Trajectory", IEEE Transactions on Industrial Electronics Early Access, 2020.
4.
L. Xing-Yuan, "A microprocessor-based fault monitor for rotating rectifiers of brushless ac exciters using a pattern-recognition approach", IEEE Instrumentation and Measurement Technology Conference, pp. 394-397, 1994.
5.
M. G. McArdle and D. J. Morrow, "Noninvasive detection of brushless exciter rotating diode failure", IEEE Transactions on Energy Conversion, vol. 19, no. 2, pp. 378-383, 2004.
6.
M. Salah, K. Bacha, A. Chaari and H. B.M. El, "Brushless Three-Phase Synchronous Generator under Rotating Diode Failure Conditions", IEEE Transactions on Energy Conversion, vol. 29, no. 3, pp. 594-601, 2014.