Abstract:
This paper presents a single-phase auto-reclosing study of a 500 kV Vietnamese transmission line. The success of the single-phase auto-reclosing depends on the extinction...Show MoreMetadata
Abstract:
This paper presents a single-phase auto-reclosing study of a 500 kV Vietnamese transmission line. The success of the single-phase auto-reclosing depends on the extinction of the secondary arc. Therefore, the influences of several factors such as shunt and neutral reactors, faulted phase and location, capacitive and inductive coupling and series capacitor discharge on the extinction of secondary arc are investigated. This paper presents the influence of single-phase auto-reclosing on the transient stability of the Vietnam system. A new method in order to reduce the dead time for single-phase auto-reclosing is proposed.
Published in: IEEE Transactions on Power Delivery ( Volume: 15, Issue: 1, January 2000)
DOI: 10.1109/61.847228
Citations are not available for this document.
Cites in Papers - |
Cites in Papers - IEEE (8)
Select All
1.
Haoxi Cong, Dong Han, Shengyao Wang, Lipan Qiao, Qingmin Li, "Experimental Study on the Extinction Characteristics of Secondary Arc Under Different Secondary Arc Currents Near Outdoor Insulator", IEEE Transactions on Dielectrics and Electrical Insulation, vol.29, no.1, pp.103-110, 2022.
2.
Lei Yang, Peng He, Chuan Xiang, Xin He, Can Xiao, Chang Chang, Dan Zhang, Run Huang, "Analysis and Research on Short-circuit Capability of Transformer in Power System Series Compensation Test", 2019 IEEE 3rd International Electrical and Energy Conference (CIEEC), pp.1393-1398, 2019.
3.
M. Jannati, B. Vahidi, S. H. Hosseinian, H. R. Baghaee, "A novel approach for optimizing dead time of extra high voltage transmission lines", 2008 11th International Conference on Optimization of Electrical and Electronic Equipment, pp.215-220, 2008.
4.
Mohammad Reza Dadash Zadeh, Majid Sanaye-Pasand, Ali Kadivar, "Investigation of Neutral Reactor Performance in Reducing Secondary Arc Current", IEEE Transactions on Power Delivery, vol.23, no.4, pp.2472-2479, 2008.
5.
M. Jannati, B. Vahidi, S.H. Hosseinian, H.R. Baghaee, "A new adaptive single phase auto-reclosure scheme for EHV transmission lines", 2008 12th International Middle-East Power System Conference, pp.203-207, 2008.
6.
M.C. Tavares, C.M. Portela, "Transmission system parameters optimization-sensitivity analysis of secondary arc current and recovery voltage", IEEE Transactions on Power Delivery, vol.19, no.3, pp.1464-1471, 2004.
7.
V.V. Terzija, Z.M. Radojevic, "Numerical algorithm for adaptive autoreclosure and protection of medium-voltage overhead lines", IEEE Transactions on Power Delivery, vol.19, no.2, pp.554-559, 2004.
8.
T. Tran-Quoc, T.A. Tran, S. Lam-Du, H. Le-Kim, U. La-Van, C. Nguyen-Duc, "Investigation of several OPF applications in the Vietnamese power system", 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495), vol.2, pp.723-728 vol.2, 2003.
Cites in Papers - Other Publishers (9)
1.
Deepthi Konda, Ujjaval Patel, Ronak Rathi, Jaynil Shah, Nilesh Chothani, "Improving protection of compensated transmission line using IoT enabled adaptive auto reclosing scheme", International Journal of Emerging Electric Power Systems, vol.0, no.0, 2023.
2.
Wei Zhang, Zhongxue Chang, Chenhao Zhang, Guobing Song, Weibin Tan, "A quick fault location and isolation method for distribution network based on adaptive reclosing", IET Generation, Transmission & Distribution, 2021.
3.
Mohsen Jannati, Jamal Moshtagh, "Hardware implementation of a real‐time adaptive single‐phase auto‐reclosure for power transmission lines", International Transactions on Electrical Energy Systems, vol.30, no.5, 2020.
4.
Mohsen Jannati, Mahdi Yazdan Nazari, "Improving the stability of power transmission lines based on an adaptive single pole auto-reclosure using a two-step strategy", IET Generation, Transmission & Distribution, vol.14, no.5, pp.873-882, 2020.
5.
Xu Zhang, Zhenyu Xu, Bo Gao, Xiaorong Xie, K. Wang, "Compensation scheme for secondary arc current on four-circuit parallel transmission lines", IET Generation, Transmission & Distribution, vol.10, no.9, pp.2079-2086, 2016.
6.
Zhenyu Xu, Xiaoqing Yan, Xu Zhang, An Wen, "Compensating scheme for limiting secondary arc current of 1000 kV ultra-high voltage long parallel lines", IET Generation, Transmission & Distribution, vol.7, no.1, pp.1-8, 2013.
7.
M. Jannati, B. Vahidi, S.H. Hosseinian, S.M. Ahadi, "A novel approach to adaptive single phase auto-reclosing scheme for EHV transmission lines", International Journal of Electrical Power & Energy Systems, vol.33, no.3, pp.639, 2011.
8.
Behrooz Vahidi, Mohsen Jannati, Seyed Hossein Hosseinian, "A Novel Approach to Adaptive Single Phase Autoreclosure Scheme for EHV Power Transmission Lines Based on Learning Error Function of ADALINE", SIMULATION, vol.84, no.12, pp.601, 2008.
9.