Abstract:
Mine trailing cables operated above safe thermal limits can cause premature insulation failure, increasing electrocution and fire hazards. Previous US Bureau of Mines (US...Show MoreMetadata
Abstract:
Mine trailing cables operated above safe thermal limits can cause premature insulation failure, increasing electrocution and fire hazards. Previous US Bureau of Mines (USBM) Pittsburgh Research Center research showed that, under static test conditions, electrical current levels permitted under present regulations may not limit cable temperatures to less than the 90/spl deg/C rating of reeled trailing cable. The USBM began a study of thermal characteristics of reeled trailing cable using dynamic test conditions more representative of field conditions where operators constantly reel in and pay out cable. This research is in support of efforts by industry associations and the Mine Safety and Health Administration to establish safety guidelines for cyclically rated reeled machines. The paper describes a unique approach to measuring temperatures within reeled cable under dynamic test conditions. Fiber-optic sensors embedded within the metallic conductors measure temperatures at 1-m intervals along the entire length of cable. Temperature measurements are reported to be accurate to within /spl plusmn/1/spl deg/C. The test setup requires access to only one end of the trailing cable, allowing researchers to freely reel in and pay out cable while temperature measurements are made, simulating field conditions. Manufacture of a fiber-optic-embedded trailing cable is described along with initial test results that indicate the fiber optic approach is viable.
Published in: IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting
Date of Conference: 06-10 October 1996
Date Added to IEEE Xplore: 06 August 2002
Print ISBN:0-7803-3544-9
Print ISSN: 0197-2618
Distributed measurement of conductor temperatures in mine trailing cables using fiber-optic technology
T.H. Dubaniewicz,P.G. Kovalchik,L.W. Scott,M.A. Fuller
Compared performances of Rayleigh Raman and Brillouin distributed temperature measurements during concrete container fire test
S. Delepine-Lesoille,I. Planes,M. Landolt,G. Hermand,O. Perrochon
Electrical Performance of the Insulation Mock-Ups for the Bi-2212 Cable-in-Conduit Conductor
Jing Sun,Zhihong Liu,Wenge Chen,Jiefeng Wu,Zhaohui Yan,Xin Luo,Xiaosong Fan
Maintenance method using 1650-nm wavelength band for optical fiber cable networks
N. Nakao,H. Izumita,T. Inoue,Y. Enomoto,N. Araki,N. Tomita
Studies on designing of submarine optical fiber cable
N. Kojima,Y. Miyajima,Y. Murakami,T. Yabuta,O. Kawata,K. Yamashita,N. Yoshizawa
Submarine optical-fiber cable containing high-strength splices
Y. Miyajima,S. Furukawa,O. Kawata
Optical fiber cables for synchronous remoting of numerous transmitters/receivers
J.E. Roman,M.Y. Frankel,K.J. Williams,R.D. Esman
Fiber strength assurance for deep-submarine optical-fiber cable using the proof-testing method
Y. Miyajima,M. Ohnishi,O. Kawata,K. Ishihara,Y. Negishi
Design of deep-sea submarine optical fiber cable
Y. Negishi,K. Ishihara,Y. Murakami,N. Yoshizawa
Axial strain in optical-fiber cable manufacture and duct installation
S. Hornung,R. Kashyap,M. Reeve,J. Russell,J. Titchmarsh