Abstract:
A reflection-type hybrid optical sensor was designed for continuous measurement of both hemoglobin content ((Hb)) and oxygen saturation (OS) of whole blood. The sensor wa...Show MoreMetadata
Abstract:
A reflection-type hybrid optical sensor was designed for continuous measurement of both hemoglobin content ((Hb)) and oxygen saturation (OS) of whole blood. The sensor was based on a theoretical model using the photon diffusion theory. The prototype sensor consists of a light emitting diode (LED) and photodiode chips mounted on a single substrate and cased in a TO-5 can with its surface covered with clear epoxy resin. The effect of hematocrit variation was eliminated. It was test in goat, calf, and human whole blood over hematocrit range of 20-45%. The modified ratio method reduced the effect of hematocrit variation of hemoglobin OS measurement with improvement in standard deviation of errors from about 7.0 to 2.0%. The standard errors in the estimation of hemoglobin content ranged from 1.5 to 0.5 gm%. The oxygen contents of whole blood derived from the prototype sensor correlated well (r=0.997) with those analyzed using a hemoximeter. The prototype sensors have been used for continuous measurement of oxygen delivery to, and oxygen consumption by, peripheral tissues in artificial heart animals for a duration of 40 days, demonstrating satisfactory performance.<>
Published in: IEEE Transactions on Biomedical Engineering ( Volume: 35, Issue: 3, March 1988)
DOI: 10.1109/10.1361
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Whole Blood ,
- Oxygen Saturation ,
- Hemoglobin Concentration ,
- Measurement Of Content ,
- Optical Sensors ,
- Hemoglobin Oxygen ,
- Measurement Of Oxygen Saturation ,
- Hemoglobin Oxygen Saturation ,
- Blood Saturation ,
- Content In Whole Blood ,
- Measurement Of Hemoglobin Content ,
- Human Blood ,
- Oxygen Consumption ,
- Peripheral Tissues ,
- Standard Deviation Error ,
- Ratio Method ,
- Human Whole Blood ,
- Diffusion Theory ,
- Mechanical Heart ,
- Dual Wavelength ,
- Red Wavelengths ,
- Light-emitting Diode Chip ,
- Reflectance Ratio ,
- Oxygen Saturation Values ,
- Red Blood Cells ,
- Penetration Depth ,
- Near-infrared Wavelengths ,
- Long-term Studies ,
- Arterial Blood ,
- Cylindrical Coordinates
- MeSH Terms
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Whole Blood ,
- Oxygen Saturation ,
- Hemoglobin Concentration ,
- Measurement Of Content ,
- Optical Sensors ,
- Hemoglobin Oxygen ,
- Measurement Of Oxygen Saturation ,
- Hemoglobin Oxygen Saturation ,
- Blood Saturation ,
- Content In Whole Blood ,
- Measurement Of Hemoglobin Content ,
- Human Blood ,
- Oxygen Consumption ,
- Peripheral Tissues ,
- Standard Deviation Error ,
- Ratio Method ,
- Human Whole Blood ,
- Diffusion Theory ,
- Mechanical Heart ,
- Dual Wavelength ,
- Red Wavelengths ,
- Light-emitting Diode Chip ,
- Reflectance Ratio ,
- Oxygen Saturation Values ,
- Red Blood Cells ,
- Penetration Depth ,
- Near-infrared Wavelengths ,
- Long-term Studies ,
- Arterial Blood ,
- Cylindrical Coordinates
- MeSH Terms