Study on Partial Discharge Characteristics under the Thermal-Electrical Coupling Effect of Epoxy-impregnated Paper Insulation in High-Voltage Dry-type Valve Side Bushing | IEEE Conference Publication | IEEE Xplore

Study on Partial Discharge Characteristics under the Thermal-Electrical Coupling Effect of Epoxy-impregnated Paper Insulation in High-Voltage Dry-type Valve Side Bushing


Abstract:

As a critical component connecting the converter transformer and the converter valve, the valve-side dry-type bushing serves both electrical insulation and mechanical sup...Show More

Abstract:

As a critical component connecting the converter transformer and the converter valve, the valve-side dry-type bushing serves both electrical insulation and mechanical support functions. However, the harsh operating environment of the valve-side bushing often leads to insulation failures due to partial discharge under long-term electro-thermal coupling effects, resulting in significant economic losses. This study investigates the degradation process of the dry-type valve-side bushing under actual operating conditions. Experimental samples of epoxy resin impregnated paper composite insulation were prepared using embedded needle electrodes. A partial discharge testing platform was established, utilizing the pulse current method to measure partial discharge characteristics under electro-thermal coupling conditions. The study examines partial discharge characteristics of epoxy resin impregnated paper composite insulation samples under positive DC bias voltage with superimposed harmonics at different frequencies, within a temperature range of 80°C to 120°C. The impact of electro-thermal coupling on the insulation was analyzed in relation to electrical tree growth. Results indicate that increasing environmental temperature significantly reduces the partial discharge inception threshold, facilitating easier initiation and development of partial discharge, thereby accelerating sample degradation. Although high-frequency harmonic content is relatively low under actual operating conditions, partial discharge activity is more intense under the superimposed effect of high-frequency harmonics. This research provides theoretical insights for the optimized design and diagnostic evaluation of valve-side dry-type bushing insulation in converter transformers.
Date of Conference: 20-24 October 2024
Date Added to IEEE Xplore: 03 December 2024
ISBN Information:

ISSN Information:

Conference Location: Gangneung, Korea, Republic of
References is not available for this document.

I. Introduction

In recent years, the valve-side dry-type bushing (hereafter referred to as the valve-side bushing) has been extensively utilized in power systems due to its oil-free operation, explosion-proof design, and high reliability [1]. Nevertheless, the operational environment for valve-side bushings is particularly severe. The primary insulation of these bushings is composed of epoxy resin impregnated paper (ERIP), which is exposed to operating voltages with high-order harmonic components. Due to the inadequate heat dissipation capabilities of solid insulation, increasing power transmission exacerbates heating issues, thereby becoming a critical bottleneck for the safe and stable operation of valve-side dry-type bushings [2]. Extended electro-thermal coupling effects frequently result in insulation failures due to partial discharges, leading to substantial direct and indirect economic losses.

Select All
1.
W Shen, W Cao and K Wu, "Study of Characteristics of Breakdown Strength and Space Charge in Epoxy/Paper Composite", CES TEMS, vol. 28, no. 1, pp. 6-35, 2013.
2.
Q. Wang, H. Wang, Z. Peng, P. Liu, T. Zhang and W. Hu, "3-D coupled electromagnetic-fluid-thermal analysis of epoxy impregnated paper converter transformer bushings", IEEE Trans. Dielect. Electr. Insul., vol. 24, no. 1, pp. 630-638, Feb. 2017.
3.
S. Bahadoorsingh and S. M. Rowland, "An investigation of the harmonic impact on electrical treeing partial discharge activity", 2010 IEEE International Symposium on Electrical Insulation San Diego CA USA, pp. 1-5, Jun. 2010.
4.
Y. Du and Y. Li, "Discharge Characteristics of Epoxy Resin Partial Discharge under Different Harmonic Voltages", 2022 9th International Forum on Electrical Engineering and Automation (IFEEA) Zhuhai China:IEEE, pp. 728-731, Nov. 2022.
5.
L. Mariut, "Temperature gradient effect on partial discharge activity-modelling and simulation", 2012 International Conference on Applied and Theoretical Electricity (ICATE) Craiova Romania, pp. 1-8, Oct. 2012.
6.
T. Sakoda, M. Kawakone, N. Hayshi and M. Setoguchi, "Material Temperature Dependence on Behavior of Partial Discharge in Epoxy Resin", 2019 IEEE Electrical Insulation Conference (EIC) Calgary AB Canada, pp. 205-208, Jun. 2019.
7.
M. Chen, X. Liu, Y. Shao, G. Shang, Q. Zhang, H. Tang, et al., "Degradation characteristics of insulation near aluminium foil edges inside dry - type bushing cores under electrothermal compound stress", High Voltage, vol. 7, no. 6, pp. 1153-1164, Dec. 2022.
Contact IEEE to Subscribe

References

References is not available for this document.