With the continuous access of large-scale distributed power sources to the grid and the expansion of the distribution network scale, it is difficult to ensure the accuracy of the traditional fault-line selection scheme for distribution networks. Considering that the new distribution network contains a large number of power electronic devices, characteristic signals can be actively injected for fau...Show More
In some wind-photovoltaic-storage power station, energy storage are gathered on 35kV AC lines. The control strategy of energy storage converter will affect the fault current external characteristics of the energy storage system, and then affect the action of line protection equipment and fault removal. To solve the above problems, based on the current mainstream energy storage converter control st...Show More
Sudden Variable Distance Protection (SVDP) has been utilized in power systems due to its extensive protection range and strong resistance to transition resistance. An in-depth study examined the fault characteristics of Doubly Fed Induction Generators (DFIG) under short circuit conditions. Special focus was given to the disparity between the positive and negative sequence impedances of DFIG and ho...Show More
In current engineering practice, short circuit current of the energy storage is affected by the pre-fault charging and discharging state, and its active component is consistent with the pre-fault state. Therefore, when energy storage encounters an access line fault in the charging state, the phase difference between the short circuit current of it and that of the system on the other side of the li...Show More
The substantial incorporation of renewable energy sources into power grids has profoundly influenced the setting calculations and accurate functioning of relay protection systems. Presently, the primary forms of renewable energy generation encompass photovoltaic (PV) systems, energy storage systems, direct-drive wind turbines, and doubly-fed induction generator (DFIG) wind turbines. Different type...Show More
With the widespread application of clean energy in power systems, traditional distribution networks have become multi-source power grids containing large-scale distributed power sources. When a fault occurs in the distribution network, it is necessary to consider the control strategy and corresponding output characteristics of distributed power sources in order to accurately remove the fault point...Show More
This paper introduces a distribution network reclosing scheme considering the low-voltage ride-through characteristics of distributed power supplies. In this paper, the impact of reclosing failure on distributed power supply off-grid is analyzed, and different reclosing strategies are adopted for circuit breakers located at different locations of faults to improve the utilization efficiency of DG ...Show More
Inverter-interfaced distributed generator (IIDG) adopts positive sequence component control strategy. When an asymmetric fault occurs, IIDG only outputs positive sequence current, making the distribution coefficients of positive and negative sequence current on IIDG side seriously unequal, which results the degradation of the performance of phase selectors based on mutation of 2-phase current diff...Show More
The application of multi-port cascaded power electronic tramsformer (PET) in AC/DC hybrid distribution network is of great significance to solve the problem of high proportion of distributed renewable energy sources and DC loads. By introducing the multi-voltage level four-port PET model, a multi-port PET cluster is proposed to optimize the operation system structure, and a dynamic energy efficien...Show More
This paper proposes a theory for locating line fault based on the basic principle of time reversal. The proof has five steps. First, the theoretical voltage and current at the ends of the line are calculated based on the transmission equation of the line in the additional network after line fault occurred. Second, the loss and lossless mirror line are established according to the parameters of the...Show More
Three time-reversal-based fault location methods are derived from the theoretical part of this paper, which is named currents-in-time-domain method, forward-currents-in-frequency-domain method, and forward-currents-in-frequency-domain-with-compensation method, respectively. The first proposed method utilizes only the decomposed transient currents in the time domain to calculate the RMS values of t...Show More
Power electronic transformer (PET) composed of modular dual active bridge (DAB) blocks has a promising future in ac-dc hybrid distribution network because of its energy routing ability. The key element that restrains the development of PET is the vulnerability of power electronic devices during faults, especially dc faults. DC faults (mostly line faults) have very short transient process and no ob...Show More
With high penetration of wind energy, the low voltage ride through (LVRT) ability of wind turbines (WTs) connected to the grid is included in recent grid codes. A novel LVRT testing method for full scale power converter WTs and the corresponding control strategies are proposed in this paper, which can emulate different types of grid faults. A virtual voltage divider is presented to realize linear ...Show More
DC line faults are a major threat for Ultra High-Voltage Direct-Current (UHVDC) transmission systems. This paper proposes a non-unit protection scheme based on transient current. The difference in transient current magnitudes can be used to differentiate the faults on the protected DC line from the inverter-side-external faults. The magnitudes of transient currents on both sides of the boundary un...Show More
With the widespread use of distributed energy and DC load (typical DC load: Data Center), more and more scholars research on the electric energy router, this paper presents a power distribution network with the application of electric energy router. Aiming at the distribution network with typical DC load data center, this paper is devoted to study the structure of the electric energy router used i...Show More
The high fault current of dc line is a major threat to multiterminal voltage-source-converter-based HVDC (VSC-HVDC) system. However, dc circuit breaker (DCCB) with large capacity and fast breaking speed is still under development. Therefore, fault current limitation is vital for the multiterminal VSC-HV DC system. This paper proposes a simple and easily applied hybrid current-limiting circuit (HCL...Show More
DC line faults are major issues for a multiterminal high-voltage direct current (HVDC) system based on voltage-source converter (VSC). The fault current increases quickly along with a large peak, and complete isolation of the faulted system is not a viable option. Therefore, protection with high selectivity and accuracy is essential. In this paper, a new protection scheme for dc line in multitermi...Show More
HVDC lines play an important role in transmission power over long distance, while faults frequently occur on DC lines due to complex terrain and terrible weather conditions, which is a major cause of HVDC outages. Traveling-wave-based protection and voltage derivate theory are used as the primary protection for HVDC transmission lines to detect a ground fault, and differential protection is employ...Show More
Distribution networks (DNs) gradually become more active and flexible with the massive integration of renewable resources. The conventional protection methods are unsuitable for the promising active DNs. This paper proposes a protection scheme on the basis of measured impedance, which includes an impedance differential method and an inverse-time low-impedance method. The former approach identifies...Show More
Jointed 12-phase-transmission lines are frequently used in power systems. However, it is subjected to a variety of technical problems on fault analysis and protection engineering. These problems are mainly due to the mutual coupling effects between adjacent circuits of the line. A method to decouple the mutual impedance completely was proposed in this paper. When fault occurs in the 12-phase-trans...Show More