This paper studied the process of implosion of the solid quasi-spherical liner driven by the axial magnetic field generated by the pulsed power source. In the experiment the pulsed power source comprising the helical EMG, the current opening switch and the transmission line provided the current pulse of 13 MA with the rise time of ~10 mus in the liner load. Two radiographic images of the quasi-sph...Show More