As the generator has advantages of high efficiency, small in size and convenience for waveform adjustment, oscillating impulse voltage has been widely used in field. The oscillating impulse voltage is generated through the RLC circuit, and all the front resistance, tail resistance, load capacitance and inductance have great influence on output waveform. By simulation the influence of inductance on...Show More
Gas insulated switchgear (GIS) is widely used in power system. With the increase of voltage level and substation scale, filed impulse voltage withstand test is increasingly important to ensure GIS safety as AC voltage withstand test becomes non-effective for the exposure of all defects. Standard lightning impulse (SLI) is normally adopted in factory, whereas oscillating lightning impulse (OLI) is ...Show More
The field impulse voltage withstand test plays one of the most important roles to ensure the safety of the gas insulated equipments. It is hard to carry out the standard impulse voltage test for the equipments because the generator is very large and difficult to transport. The oscillating impulse voltage waveform has high efficiency and has been recommended by the IEC 60060-3 as the field test wav...Show More
Gas insulated switchgear (GIS) is the most important equipment in grid. It has been widely used in power system for the merits of small size and high reliability. Especially for the city substation, GIS is the preferred power equipment. GIS has the compact structure and it is difficult to repair once there are defects inside the GIS. It is the important step to monitor the defects inside GIS. PD i...Show More
Gas insulated switchgear (GIS) has been widely used in electric power system for its high reliability and the small size. And considering the transportation difficulty GIS is always assembled in field. The AC withstand voltage testing is used on the spot to check the insulation condition of GIS, but it is not enough to inspect all the defects inside GIS. So impulse voltage testing is required. But...Show More
GIS has excellent performance and is widely used in electric power system. Its delivery test usually is standard impact which is applied in examination of its insulation, but in the field test, the oscillating impulse voltage waveform is often used. So the assessment ability in SF6 insulation of oscillating impulse voltage and the equivalent relation of two types impulse voltages is worthy of furt...Show More