Loading [MathJax]/extensions/MathMenu.js
Impact of Considering Surger Arresters to Reduce Lightning Induced Voltage: emphasis on the Grounding Modeling | IEEE Conference Publication | IEEE Xplore

Impact of Considering Surger Arresters to Reduce Lightning Induced Voltage: emphasis on the Grounding Modeling


Abstract:

Lightning-related phenomena are one of the most dangerous factors affecting the overhead distribution systems. Said that, protective measures to reduce lightning damages ...Show More

Abstract:

Lightning-related phenomena are one of the most dangerous factors affecting the overhead distribution systems. Said that, protective measures to reduce lightning damages are an important issue to guarantee distribution line reliability. The most widely employed protective measures against lightning are: shield wires, surge arresters, and increasing the line insulation level, usually by increasing the length of insulator strings. Among the aforementioned techniques, one that deserves a special attention is installing lightning arresters, since it can be very effective and commonly used in reducing lightning overvoltage. In this way, this paper presents a comparative study of the induced overvoltage calculation along insulator strings due to indirect lightning strikes in the distribution lines with and without the installation of surger arresters and comparing results considering a simple and rigorous modeling of the pole-footing grounding system. Furthermore, a simplified representation of the model of the pole-footing grounding system, in which the surge arresters will be installed, commonly adopted may lead to an underestimation of the overvoltage. The results point that the surge arresters are able to isolate the propagation of the induced voltages in adjacent poles by positioning them at poles in alternate pattern. The maximum voltage difference found when considering the rigorous model instead of the simplified model of the pole-footing grounding system, for the cases studied, was around 6.42%.
Date of Conference: 17-18 November 2022
Date Added to IEEE Xplore: 13 December 2022
ISBN Information:

ISSN Information:

Conference Location: Fortaleza, Brazil
References is not available for this document.

I. Introduction

Indirect lightning in overhead distribution lines are one of the most important issues when dealing with lightning protection systems. Thus, it has motivated several researchers to investigate the electromagnetic fields and the resulting lightning induced voltages (LIV).

Select All
1.
M. Brignone, F. Delfino, R. Procopio, M. Rossi and F. Rachidi, "Evaluation of Power System Lightning Performance Part I: Model and Numerical Solution Using the PSCAD-EMTDC Platform", IEEE Transactions on Electromagnetic Compatibility, vol. 59, no. 1, pp. 137-145, feb 2017.
2.
A. Andreotti, R. Araneo and A. Pierno, "A survey on analytical solutions and tools for lightning-induced voltages calculations", Electric Power Systems Research, vol. 194, pp. 107104, may 2021.
3.
J. O. S. Paulino and C. F. Barbosa, "Effect of high-resistivity ground on the lightning performance of overhead lines", Electric Power Systems Research, vol. 172, pp. 253-259, jul 2019.
4.
L. Farina, D. Mestriner, R. Procopio, M. Brignone and F. Delfino, "The Lightning Power Electromagnetic Simulator for Transient Overvoltages (LIGHT-PESTO) Code: A User-Friendly Interface With the MATLAB-Simulink Environment", IEEE Letters on Electromagnetic Compatibility Practice and Applications, vol. 2, no. 4, pp. 119-123, feb 2022.
5.
M. Brignone, D. Mestriner, R. Procopio, A. Piantini and F. Rachidi, "Evaluation of the mitigation effect of the shield wires on lightning induced overvoltages in MV distribution systems using statistical analysis", IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 5, pp. 1400-1408, 2018.
6.
A. Piantini, J. M. Janiszewski, A. Borghetti, C. A. Nucci and M. Paolone, "A scale model for the study of the LEMP response of complex power distribution networks", IEEE Transactions on Power Delivery, vol. 22, no. 1, pp. 710-720, 2007.
7.
A. Piantini and J. M. Janiszewski, "The use of shield wires for reducing induced voltages from lightning electromagnetic fields", Electric Power Systems Research, vol. 94, pp. 46-53, 2013.
8.
D. Mestriner, R. Antônio, R. De Moura, R. Procopio and M. Aurélio De Oliveira Schroeder, "Impact of Grounding Modeling on Lightning-Induced Voltages Evaluation in Distribution Lines", Applied Sciences 2021 vol. 11 Page 2931, vol. 11, no. 7, pp. 2931, mar 2021.
9.
M. A. Sargent and M. Darveniza, "Tower Surge Impedance", IEEE Transactions on Power Apparatus and Systems, vol. PAS-88, no. 5, pp. 680-687, 1969.
10.
S. Visacro and A. Soares, "HEM: A model for simulation of lightning-related engineering problems", IEEE Transactions on Power Delivery, vol. 20, no. 21, pp. 1206-1208, 2005.
11.
Impact of soil-parameter frequency dependence on the response of grounding electrodes and on the lightning performance of electrical systems, pp. 67, 2019.
12.
R. S. Alípio and S. Visacro, "Modeling the frequency dependence of electrical parameters of soil", IEEE Transactions on Electromagnetic Compatibility, vol. 56, no. 5, pp. 1163-1171, oct 2014.
13.
B. Gustavsen and A. Semlyen, "Rational approximation of frequency domain responses by vector fitting", IEEE Transactions on Power Delivery, vol. 14, no. 3, pp. 1052-1061, 1999.
14.
"Working Group on Surge Arrester Modeling of Metal Oxide Surge Arresters", IEEE Transactions on Power Delivery, vol. 7, no. 1, pp. 302-309, 1992.
15.
F. Rachidi, W. Janischewskyj, A. Hussein, C. Nucci, S. Guerrieri, B. Kordi, et al., "Current and electromagnetic field associated with lightning-return strokes to tall towers", IEEE Transactions on Electromagnetic Compatibility, vol. 43, no. 3, pp. 356-367, 2001.

Contact IEEE to Subscribe

References