The localization of spontaneous brain activity: an efficient way to analyze large data sets | IEEE Journals & Magazine | IEEE Xplore

The localization of spontaneous brain activity: an efficient way to analyze large data sets


Abstract:

An efficient solution is presented of the problem to localize the electric generators of spontaneous magnetoencephalography (MEG) and electroencephalography (EEG) data fo...Show More

Abstract:

An efficient solution is presented of the problem to localize the electric generators of spontaneous magnetoencephalography (MEG) and electroencephalography (EEG) data for large data sets. When a data set contains more than 100,000 samples standard methods fail or become impractical. The method presented here is useful, for example, for the localization of (pathological) brain rhythms or the analysis of single-trial data. The problem is defined as finding the good fitting dipoles using the single-dipole model applied on each time sample. First, the data is bandpass filtered to select the rhythm of interest. Next, the empirical relationship between data power and probability of a dipole with a high goodness of fit (g.o.f.) is used to preselect data points. Then a global search algorithm is applied, based on precomputed lead fields on a fixed grid, to obtain a good initial guess for the nonlinear dipole search. Finally, the dipole search is applied on those samples that have a low initial guess error. In a group of five patients, it is found that 50% of the dipoles with a g.o.f. of at least 90% can be found by disregarding 90% of the data samples. Those dipoles can be found efficiently by disregarding all sample points with an initial guess relative residual error of 15% or lower. Finally, a simple empirical expression is found for the optimal mesh size of the global search grid. The method is completely automatic and makes it possible to study simple generators of large MEG and EEG data sets on a routine basis.
Published in: IEEE Transactions on Biomedical Engineering ( Volume: 48, Issue: 11, November 2001)
Page(s): 1221 - 1228
Date of Publication: 07 August 2002

ISSN Information:

PubMed ID: 11686621
No metrics found for this document.

I. Introduction

Multichannel magnetoencephalography and electroencephalography (M/EEG) can be used to study the relationship between the physiological condition of a subject or the applied stimulus and the distribution of electrical activity in the brain. An accurate localization of the brain activity requires mathematical models that give the relationship between the measured M/EEG, the conductivity of the head and the geometry of the electric sources. The simplest of these models consists of a single electric current dipole embedded in a spherically symmetric conductor. More advanced models allow more dipoles and restrict the time variations of the dipole parameters as stationary or rotating dipoles (e.g., [1], [2], and [19]). Furthermore, distributed source models have been developed in which electric brain activity is described as extended sources projected on the cortex [3] or in 3-D space [4].

Usage
Select a Year
2023

View as

Total usage sinceFeb 2011:142
00.511.522.53JanFebMarAprMayJunJulAugSepOctNovDec020200000000
Year Total:4
Data is updated monthly. Usage includes PDF downloads and HTML views.
Contact IEEE to Subscribe

References

References is not available for this document.