Abstract:
Triaxial measurement is an effective means to determine the transfer impedance of a shielded cable. It is based on coupled transmission line principle. In an ideal case, ...Show MoreMetadata
Abstract:
Triaxial measurement is an effective means to determine the transfer impedance of a shielded cable. It is based on coupled transmission line principle. In an ideal case, both transmission lines in the setup would be matched to guarantee the high frequency performance. In practice, matching is hard to achieve without compromising on usability and generality of the measurement setup. This paper discusses how triaxial cell diameter and the resulting impedance mismatch affects transfer impedance measurement results. In addition, the paper shows how impedance mismatches can be modeled, presents a simplified model to quickly understand the effects of impedance mismatch, and compares the model to results measured with different triaxial cell sizes. The simple model presented achieved similar accuracy to a more complex model defined in IEC 62153.
Date of Conference: 26 July 2021 - 13 August 2021
Date Added to IEEE Xplore: 19 October 2021
ISBN Information: