Introduction
Two-way communication between the grid and the user is the main aspect of the smart grid distribution system. This two-way communication can elegantly and optimally perform by optical fiber composite low voltage (OPLC) cable [1]. OPLC cable is a way to control the load from the electricity generating stations and means to carry out the demand side management to reduce the peak hours of the load by reducing the risk of blackouts [2]. In OPLC cable, the optical unit is stranded together with the conductors, serving both functions of transmitting power and communication in a single cable [3], [4]. The OPLC cable is used in the distribution networks having a low power rating of 1 kV. OPLC is constructed on an idea of power fiber to the home (PFTTH) [5]. This cable can integrate the electrical distribution networks with a communication network to connect the smart grid with smart meters [6]. In China, after the successful implementation of optical fiber-composite PVC insulated drop wire (OPDV) and optical fiber ground wire (OPGW) by State Grid Corporation of China, dominant support is gained by OPLC from the government to be mounted in distribution networks [7], [8]. A lot of work has been done in analyzing the electrostatic and magnetic field in submarine cables having the optical fiber serving as a sensor for monitoring the temperature distribution inside the cable [9]. Dmitriev did the electrical and thermal analysis of optical ground wire cables by using the finite element method by integrating the coupled equations [10]. Guoda did the electrothermal analysis of low and medium voltage cables using the finite element method [11]. Yuqing did the condition monitoring of OPLC cable by using the optical fiber temperature monitoring technology [1]. In previous researches, the work that had been carried out by most of the researchers is related to the electric field analysis, thermal analysis, magnetic field analysis, structural optimization by considering the thermal field and condition monitoring [12]–[14]. The simulation study was conducted by Wang on the optical fiber to relate the increase of stress due to increase of temperature in bare optical fiber [15] but the study was not enough because of an absence of experimental setup also the simulation study includes only the bare fiber. The study of selection of heat resistant layer for the optical unit of OPLC cable by analyzing the increase of temperature and stress is conducted for the first time in this paper along with the simulation and experiment results. Before going into the manufacturing phase it is the need of the hour to analyze the possible factors that can affect the performance of the OPLC cable, so in this paper, the temperature and stress distribution in OPLC cable is being analyzed. The structure of OPLC cable is simulated in COMSOL by using the finite element method. As the current flow in the conductors, the heat is generated due to the resistive property of conductor that causes the increase of temperature in the cable. The temperature rise due to the current flowing in the cable results in the expansion of layers due to their thermal expansion coefficient that generates the stress in the cable [16]. The internal stress generated in the OPLC cable can cause the deformation of optical fiber structure that results in attenuation [17], [18]. In the normal operating condition, the current flow in the cable caused the temperature of the conductor to increase and due to the different thermal coefficients of insulation layers, the heat is transferred towards the outer layers by creating a thermal field within the cable. The stress is generated due to the increase in temperature that forces the insulation layers to expand at different temperatures and create stress in the cable [19].
In this paper, the structure of OPLC cable and materials in the insulation of OPLC cable are explained. The thermal field distribution and thermal stress in normal operating conditions and overload conditions simulation by using the coupled equations in COMSOL for the selection of the most suitable heat resistant layer that can restrict the increase of temperature and stress to the minimum level. The selected heat resistant layer is used in the sample of the cable for the experiment. The experimental platform is set up to analyze the increase in temperature and stress in the cable by using the Brillouin optical time-domain analysis as the current flows in the conductors and the experimental results are compared with the simulated results.
Problem Description
The OPLC cable is designed to use for carrying out the functions of transmitting electricity as well as the communication signal. The cable consists of different insulation layers, as the temperature at the conductor rises, the heat transfers to the outer layers causing the rise in the temperature at the optical unit that is stranded along the conductors. The increase in temperature causes the insulation layers to expand by generating stress within the cable. This increase in temperature and stress is the reason to increase the attenuation in optical fiber [18]. The block diagram of the generation of temperature and stress in a cable is shown in Fig. 1. In the block diagram two prominent factors, temperature, and stress are shown that contribute to the attenuation of communication signals.
The system diagram of OPLC cable comprises temperature and stress being prominent factors in influencing the attenuation loss.
The objective of the research is to minimize the attenuation in the optical fiber signal occurs due to the increase of temperature and stress. To attain the goal, these two factors, temperature and stress have to be restricted to their minimum value. One of the problems in the OPLC project is the appropriate choice of heat resistant material that can limit the temperature and stress to the minimum value so that the attenuation in the fiber can be minimized. The other problem is to accurately analyze the increase in temperature and stress in the cable at the rated current of OPLC cable.
The first problem of choosing the material for the heat resistant layer is solved in this paper by using the coupled equations model by applying the finite element method using the COMSOL Multiphysics software. Three different types of materials are analyzed for the increase in temperature at the optical fiber as the temperature of the conductor becomes 90°C. The material that allows the minimum increase in temperature and stress at the optical fiber is chosen as the heat resistant layer. The second problem, to analyze the accurate increase in the stress and temperature in the cable is solved by putting the cable in the experiment setup. In the experiment setup, the temperature and stress inside the cable are analyzed by using the Brillouin optical time-domain analysis (BOTDA) technique. The experiment results are compared with the simulation results obtained by using the coupled equations in COMSOL Multiphysics software.
Structure and Materials of OPLC
OPLC cable consists of an electrical power transmitting conductor stranded together with the optical unit. There are different structures of OPLC cables consisting of the 3-phase cable and 1-phase cable [20]. OPLC-WDZ-YJY-0.6/ 1kV-3x10+GQ-2B6a is a single-phase cable having phase, neutral, and earth wire along with the optical unit that comprises the optical fiber. Each conductor has an area of 10 mm2 and the insulation of cross-linked polyethylene XLPE having a thickness of 0.7 mm. The outer insulation layer of the OPLC cable is polyethylene (PE) having a thickness of 1.8 mm. The insulation materials used in the optical unit are heat resistant layer, for heat resistant layer three materials polyethylene PE, cross-linked polyethylene XLPE, and thermoplastic elastomer TPE are taken under consideration. The modeling of the cable is shown in section 4. OPLC-WDZ-YJY-0.6/ 1kV-3x10+GQ-2B6a is shown in Fig. 2.
The properties of materials used in the cable include thermal conductivity “
Mathematical and FEM Modelling
OPLC cable is modeled in COMSOL Multiphysics to analyze the temperature and stress increase as the AC flows in the cable [21]. Previously ELEFANT 2D software was used to analyze the temperature distribution in cable [22]. In COMSOL, the study includes the heat transfer with the magnetic field to make the AC flow in the cable and calculate the temperature field distribution [23]. Solid mechanics is included in the simulation study to simulate the thermal stress developed between the layers of the cable. In a magnetic field, the AC flows through the axis of the cable. Maxwell’s equations for the frequency domain are used to find the solution for magnetic fields [24]. The magnetic field density produced the current and the relationship is given by ampere’s law as in (1).\begin{equation*} \nabla \times H=J\tag{1}\end{equation*}
Here \begin{equation*} J=\sigma (E+v\times B)+J_{e}\tag{2}\end{equation*}
Here \begin{equation*} Q_{rh} =\frac {\left |{ J }\right |^{2}}{2\sigma }=\frac {\text {Re}(J\cdot E^{\ast })}{2}\tag{3}\end{equation*}
The first law of thermodynamics is used in the simulation to calculate the heat transfer in solids that include resistive losses due to electromagnetic waves. The equation for current density is coupled with the production of heat due to resistive losses. The heat equation is expressed in temperature T instead of internal energy U as in (4).\begin{align*} \sigma C_{P} \left ({{\frac {\partial T}{\partial t}+(u\cdot \nabla)T} }\right)=&-(\nabla \cdot q)+\tau:\varepsilon \\&-\,\frac {T}{\rho }\left.{ {\frac {\partial \rho }{\partial T}} }\right |_{p} \left ({{\frac {\partial p}{\partial t}+(u\cdot \nabla)p} }\right)\!+\!Q \\\tag{4}\end{align*}
Here \begin{equation*} \frac {\partial \rho }{\partial t}+\nabla \cdot (\rho v)=0\tag{5}\end{equation*}
Fourier’s law of heat conduction states the conductive heat flux is proportional to the gradient of temperature as in (6) [25], [26].\begin{equation*} q=-k\frac {\partial T}{\partial x}\tag{6}\end{equation*}
Here \begin{equation*} \rho C_{P} \frac {\partial T}{\partial t}+\rho C_{P} u\cdot \nabla T=\nabla \cdot (k\nabla T)+Q\tag{7}\end{equation*}
Here the heat due to electromagnetic resistive losses \begin{equation*} Q_{rh} =-\nabla \cdot (k\nabla T)\tag{8}\end{equation*}
The temperature rise caused the deformation of the structure of the cable due to the thermal expansion coefficient of different insulation materials. The expansion caused stress between the insulating layers. This stress is calculated by including the study of solid mechanics. The interface of solid mechanics defines the deformation of solid objects in the physical space called a spatial frame. When the solid object distorts due to internal thermal stress, every particle keeps its reference coordinates \begin{equation*} x=X+u(X,t)\tag{9}\end{equation*}
Here \begin{align*} \nabla u=\left [{ {\begin{array}{l} \dfrac {\partial u}{\partial X}\dfrac {\partial u}{\partial Y}\dfrac {\partial u}{\partial Z} \\[0.4pc] \dfrac {\partial v}{\partial X}\dfrac {\partial v}{\partial Y}\dfrac {\partial v}{\partial Z} \\[0.4pc] \dfrac {\partial w}{\partial X}\dfrac {\partial w}{\partial Y}\dfrac {\partial w}{\partial Z} \end{array}} }\right]\tag{10}\end{align*}
Here, \begin{equation*} \varepsilon =\frac {1}{2}(\nabla u^{T}+\nabla u)\tag{11}\end{equation*}
The system model used in COMSOL, integrating the heat transfer with the structural mechanics model is shown in Fig. 3. The system model shows the interconnection of equations and their influence.
The model is built in AutoCAD software and geometry is exported in COMSOL. The material properties of the cable are added. The study of a magnetic field is integrated with the study of heat transfer in solids to get the temperature increase in the cable. The boundary condition of the simulation is the outside environment temperature that is taken at 20°C. The mesh is applied to the cable structure and is shown in Fig. 4.
A. Analysis of Temperature Field Distribution Using FEM
The first material is chosen to be polyethylene PE. PE has been one of the top choices in the insulation materials for cables having a thermal conductivity of
The second material is chosen to be cross-linked polyethylene XLPE. It is the popular insulation material for the cables having a low thermal conductivity of 0.285 W/m·K. The low thermal conductivity allows it to restrict the temperature increase across the insulation layer. As the temperature of the conductor becomes 90 °C due to the heat transfer, the temperature of the optical unit is increased up to 71.27°C. Under an overload condition, the temperature of the optical fiber becomes 77.81°C.
The third material is thermoplastic elastomer TPE having a low thermal conductivity of
The optical unit is placed away from the center of the cable to minimize the increase of temperature as the temperature in the center of the cable is relatively higher than the side of one conductor because in the center heat is transmitted from both conductors. The temperature is further decreased to 2°C at the optical fiber as TPE is used as a heat resistant layer for optical unit. The temperature distribution in the OPLC cable by using PE, XLPE, and TPE at different parts of the cable are shown in Table 2.
It is evident from the above simulations that TPE restricts the increase of temperature at the optical fiber comparatively better than PE and XLPE. The temperature increase can be restricted more by using the optimization algorithms that include the constraints of increasing or decreasing the layer width but at the current stage of the project, the study is conducted on the selection of heat resistant layer that can limit the increase of temperature and stress. We have fixed the width of the heat resistant layer and placed the optical fiber away from the conductors because the temperature at the conductors is at its highest value that can cause more temperature increase if the optical unit is placed in the center of the cable near to the conductors. If the width of the heat resistant layer is increased, the temperature might decrease a little but this will cause an increase of stress as there will be more expansion of insulation layers due to the thermal expansion coefficient of material and increase of stress at the fiber will contribute in attenuating the signal in optical fiber.
B. Analysis of Stress Field Distribution Using FEM
The temperature distribution in three materials PE, XLPE, and TPE show the minimum temperature increase in TPE that makes it the best option for the heat resistant layer. TPE has the lowest thermal conductivity of
Stress is generated at optical fiber by TPE, XLPE, and PE as a heat resistant layer.
The temperature and stress on the optical fiber rise to 70 °C and
In COMSOL, structural mechanics is added that links the heat transfer module with the solid mechanics. In this way, simulation is carried out that calculates the amount of stress generated in the cable as the heat flow in the conductors. The dark blue areas that are away from the conductors show the low stress and the light areas show the high-stress concentration at the optical fiber in the cable. One side that is close to the conductors shows more stress due to the expansion of layers in the cable.
The above simulation results make the TPE the most suitable choice for the heat resistant layer for the optical unit of OPLC cable. The TPE is used as the heat resistant layer in the manufacturing of OPLC cable and the cable is put in the experiment platform to analyze the increase of temperature and stress in real-time at normal operating conditions and under overload conditions. The experimental analysis for the increase of temperature and stress at different current levels are given in section V.
Experimental Analysis
The optical unit in the cable is used to measure the strain inside the cable. The increase in strain is analyzed by using Brillouin optical time-domain analysis (BOTDA). BOTDA technology is a measurement technique that indicates the increase of temperature and strain along with the optical fiber. In the BOTDA sensing technique, the pump and probe light is injected from the starting and ending points of optical fiber respectively. The disturbance due to temperature and strain makes the frequency difference between pump and probe light, this difference equals the frequency shift. The frequency shift \begin{equation*} v_{B}=C_{\varepsilon } \Delta _{\varepsilon } +C_{T}\Delta T+v_{B0}\tag{12}\end{equation*}
Here, \begin{equation*} \sigma =E\cdot \varepsilon\tag{13}\end{equation*}
In Section IV, simulation is done by using three different materials for the heat resistant layer. Thermoplastic elastomer TPE turns out to be the best among them. Based on the simulation results TPE is used in the manufacturing of the real cable sample and the sample of OPLC cable is put in the experiment setup to analyze the increase of temperature and strain in real-time as the current flows in the cable. To accurately measure the increase of strain in cable, a BOTDA analyzer is used. BOTDA analyzer records the frequency shift that increases due to the increase of temperature and strain. The frequency shift along with the increase of temperature measured by temperature sensors inserted in the cable is put in (12). Two experiments are conducted in Section V to analyze the coefficient of temperature CT and coefficient of strain
A. Analysis of Temperature and Strain Coefficient
The temperature influence coefficient
The Brillouin frequency shift increases as the strain in the fiber increase making the linear relationship between the frequency shift and the applied strain. To get this linear relation, the strain is produced in the single-mode fiber and frequency shift is recorded at the same time by using BOTDA. To produce the strain in optical fiber, one end of the fiber is attached to the fixed end and the other end is attached to the movable end. Both ends of the optical fiber are connected to the BOTDA. The optical fiber is attached in a strain-free state. The reference frequency shift is recorded in a strain-free state of optical fiber. The controlled displacement is given to the high-precision displacement platform of 0.01 mm and at the same time the BOTDA recorded the frequency shift. The BOTDA analyzer recorded the data up to 0.05 mm displacement given by high-precision displacement platform to produce the strain in the optical fiber. The frequency shift and increase in strain is put in (12) to get the value of coefficient of strain as 0.052 MHz/
B. Analysis of Temperature and Strain in OPLC Cable
In the experimental setup, the temperature and stress in the OPLC cable are analyzed by injecting the current to flow in conductors. The flow of current resulted in the increase of temperature that is being measured by temperature sensors inserted in the OPLC cable and an increase of thermal stress is measured by calculating the strain by BOTDA analyzer. The OPLC cable used in the experimental setup has TPE as a heat resistant layer. In OPLC cable there are two single-mode fibers (SMF), SMF-1 is connected to the BOTDA analyzer and SMF-2 is connected to the light source and power energy meter to ensure the continuity of optical signal during the current flow. Optical fiber splicer is used to connect the optical fiber with the connector having a loss of 0.01 dB, the two ends of the SMF-2 is connected with the Thorlabs S155C connector having the capacity to transmit 20 mW of power from the light source to the power energy meter. One end of SMF-1 is connected to the probe end of BOTDA and the other end is connected to the pump end of BOTDA. The current is produced in the cable by the magnetic field generated by the high current generator that is controlled by the variable transformer. The OPLC cable passed through the core of the current generating transformer that generates the magnetic field resulting in the generation of current in the cable. The variable transformer is used to control the current generated in the OPLC cable. The variable transformer is connected with the primary winding of the current generator that controls the value of current. The cable is cut open and temperature sensors are placed inside at different points of cable and after placing the temperature sensors the cable is put into the original closed state. The temperature sensors are placed at different points inside the cable to measure the temperature of the conductors and optical fiber as the current flows inside the cable. The data acquisition module is used for the computer interface to save the temperature data in real-time. The variable transformer is used to regulate the current at different levels and kept the same level of current for 2 hours until the temperature inside the cable became constant. As the temperature becomes stable inside the cable BOTDA records the frequency shift. The experiment platform is shown in Fig. 10.
Experimental platform for analyzing the increase in temperature and strain in OPLC cable.
Results and Discussion
A. Results
1) Analysis of Temperature Coefficient
For single-mode fiber, the BOTDA analyzer recorded the frequency shift at temperature starting from 20°C to 70°C with a step size of 10°C. The recorded frequency shift with temperatures is fitted in MATLAB curve fitting that gave the value of temperature coefficient of 1.089 MHz/°C. The obtained value of the temperature coefficient is in a good range with the Brillouin temperature coefficient delivered by most manufacturers. The results of the frequency shift are recorded by BOTDA analysis and put in (12) to get the temperature coefficient
2) Analysis of Strain Coefficient
The frequency shift recorded by using Brillouin optical time-domain analysis is given in Table 4. The coefficient of strain is calculated by (12) as 0.052 MHz/
The MATLAB fitting curve between the frequency shift and strain
3) Analysis of Temperature and Strain in OPLC Cable
The experiment started with no current in the cable and the BOTDA analyzer recorded the initial frequency shift having initial temperature and initial strain that is used as the reference value. The current of 20 A is injected in the cable for 2 hours to stabilize the temperature increase within the cable. As the temperature in the cable becomes stable the BOTDA analyzer again measures the frequency shift for the temperature and strain measurement. The process is repeated with the step size of 20 A current until the temperature of the conductor reached up to the overload condition of 99°C. The increase of temperature in the conductor and optical fiber with the increase of current is measured by using the temperature sensors inserted inside the cable. The BOTDA analyzer recorded the frequency shift at the current levels with a step size of 20°C. The temperature of conductor and optical fiber simulated in COMSOL is compared with the experimental results and shown in Fig. 13.
The temperature increase in the conductor and optical fiber as the current flow in OPLC cable.
The maximum operating temperature for XLPE insulated conductors is taken at 90°C which occurs at 92 A of current. The length of the cable is 10 meters starting from 5 m to 15 m. The first 5 meters of fiber include the connecting fibers from cable to the BOTDA analyzer. The frequency shift at different current levels is shown in Fig. 14.
Brillouin frequency shifts due to stress and temperature in the OPLC during the operating condition.
The starting end of the cable is connected with the optical fiber that is further connected to the BOTDA analyzer. The frequency shift at 92 A current is also recorded by the BOTDA analyzer. As the current increased, the temperature and stress at the optical fiber increased and the increasing Brillouin frequency shift is the proof. The Brillouin frequency shift for 0 A current is taken as reference and (12) is used to find the strain in the optical fiber. The Brillouin frequency shift, temperature coefficient, temperature of optical fiber, and strain coefficient is put in (12) to get the strain. This strain is then put in (13) to get the stress in optical fiber. The increase in stress in the experimental analysis compared with the simulated stress is shown in Fig. 15.
B. Discussion
In OPLC cable the optical unit is stranded with the conductors and the flow of current in the conductors generates the increase in temperature and stress on the optical fiber that is capable of influencing the attenuation in the optical signal. The increase in attenuation of the signal has a direct relation with the increase of temperature and stress so currently, the research carried out in this paper is more focused on the selection of heat resistant layer for the optical unit of OPLC that restricts the temperature and stress to the value as minimum as possible. At the current stage of the project, the experiment is performed on OPLC cable of 10-meter length. To relate the attenuation with temperature and strain, 1 km long OPLC cable is required because it is the only way to correctly analyze and relate the attenuation with temperature and stress. The state of the art power source and power energy meter has a fluctuation error of +0.003 dB/km. The standard for optical fiber communication is 0.15 dB/km, which means that for 10-meter cable the attenuation must be below 0.0015 dB/km that is not possible to measure with the currently available equipment. For that 1 km long OPLC cable is required, so at the current stage of project it is not possible to relate the attenuation with the increase of temperature and stress experimentally. As the attenuation of signal has a direct relation with temperature and stress so by decreasing the increase of these two factors it is possible to decrease the attenuation in signal. To decrease the effect of these factors, an appropriate heat resistance layer is chosen as the outer insulation material for the optical unit. For the heat resistance material, a thermoplastic elastomer is selected as it restricts the temperature and stress to its minimum limit.
In the simulation section thermoplastic elastomer TPE shows relatively better performance than polyethylene PE and cross-linked polyethylene XLPE in restricting the increase in temperature and strain due to its low thermal conductivity and high poisons ratio. The low thermal conductivity restricted the increase of temperature and the high poisons ratio restricted the materials to expand upon the temperature increase that further helped to decrease the stress generated due to thermal expansion of heat resistant layer on the optical fiber. Due to these promising features TPE is used as the heat resistant layer in OPLC cable sample to be put in the experiment setup. In the experiment set up as the temperature sensors are inserted inside the cable so in the process, there is a small chance of leakage of heat from the cable that is the reason, the simulation temperature is slightly higher than the experiment results. The increase of temperature and stress due to the current flow is inevitable but the optimal choice of heat resistant layer helped to restricts the increase of temperature and stress to the minimum value. As the current begins to flow the temperature at the conductors begins to rise due to the resistive losses of the conductor. This temperature increase causes the insulation layers of the OPLC cable particularly the heat resistant layer of optical unit to expand in all directions. The expansion of heat resistant layer towards the optical fiber generates stress on the optical fiber. The increase in temperature attenuates the communication signal and the stress generated due to the increase of temperature further attenuates the signal. To reduce the attenuation in optical fiber it is necessary to restrict these two factors to their minimum value possible.
In normal operating conditions, the maximum current of 92 A in the OPLC cable makes the temperature of the conductor rise to 89.7°C. The temperature is distributed in the cable and the experiment results illustrated that the temperature at the optical fiber rise to 69°C. The increase in temperature in the OPLC cable caused the insulation layers to expand which resulted in the stress between the layers of the OPLC cable. The Brillouin optical time-domain analysis is performed while the current circulated in the OPLC cable. SMF-1 is connected to the BOTDA analyzer to measure the frequency shift as the temperature and stress began to rise with the rise of current. This frequency shift is then used to calculate the thermal stress in the OPLC cable. The thermal stress on the optical fiber is experimentally calculated as
Conclusion
In this paper, three materials have been simulated for analyzing the distribution of temperature and stress in OPLC cable at the optical fiber. TPE is selected as the best option as a heat resistant layer as it restricts the temperature and stress to its minimum value among PE and XLPE. It is important to restrict these two factors as these two factors are capable of affecting the performance of OPLC cable by attenuating the optical signal. As the current flows the heat generated from the conductors flows outside that causes the increase of temperature at the optical fiber. The temperature increase causes the generation of stress within the layers and this stress is capable of deforming the structure of the optical fiber. Two cases had been discussed as normal operating conditions and overload conditions. At normal operating conditions, the TPE heat resistant layer restricts the temperature and stress to 69°C and