Calibration of a precision current measurement system for high AC voltages using an AC Quantum Voltmeter | IEEE Conference Publication | IEEE Xplore

Calibration of a precision current measurement system for high AC voltages using an AC Quantum Voltmeter


Abstract:

This paper describes the experimental application of the AC Quantum Voltmeter for the calibration of a high precision measurement system for high AC voltages, both develo...Show More

Abstract:

This paper describes the experimental application of the AC Quantum Voltmeter for the calibration of a high precision measurement system for high AC voltages, both developed at PTB. Measurements are based on its use as DC quantum standard for resistance comparisons, and as AC quantum standard for AC current measurement, in a time series.
Date of Conference: 24-28 August 2020
Date Added to IEEE Xplore: 10 September 2020
ISBN Information:

ISSN Information:

Conference Location: Denver, CO, USA
No metrics found for this document.

I. Introduction

At PTB a precision measurement system for high AC voltages (PS-HVAC) was developed and presented in [1]–[3]. This system is intended to be used as the national standard for high AC voltages up to 800 kV with an overall uncertainty of . It is based on the measurement of a 50 Hz loading current of a high voltage capacitor, and the analogue conversion of this current to a reference voltage. Traceable 50 Hz currents from 0.15 mA to 50 mA are required for calibrating the instrument on its 7 measuring ranges.