Abstract:

Hemoglobin concentration, as an important indicator of the recovery of the surgical site of the flap graft, can reflect the state of blood circulation. Current methods fo...Show More

Abstract:

Hemoglobin concentration, as an important indicator of the recovery of the surgical site of the flap graft, can reflect the state of blood circulation. Current methods for monitoring blood flow after surgery are limited to physical observations and empirical diagnosis of skin temperature, color, and swelling, or only rough determination of oxygen saturation, and less to realtime monitoring of hemoglobin concentration. In this paper, a multi-directional reflective non-invasive test system for detecting hemoglobin concentration after skin flap transplantation was designed and constructed. Through the collection and analysis of sample data, a correction factor was introduced to achieve noninvasive detection of hemoglobin concentration. The experimental results showed that the standard deviation of 10 consecutive measurements of 6 volunteers was relatively small; the correlation between 40 measurement value and true value was relatively strong; the concentration of hemoglobin collected after skin heating was sensitive to temperature changes, indicating that the system has good stability, accuracy and effectiveness. The project team will cooperate with the Huaihe Hospital of Henan University to conduct clinical testing of hemoglobin concentration in patients after flap transplantation, further calibrate the data and develop miniaturized portable measuring instruments to provide more reliable basis for postoperative care.
Date of Conference: 13-15 October 2018
Date Added to IEEE Xplore: 03 February 2019
ISBN Information:
Conference Location: Beijing, China
References is not available for this document.

I. Introduction

Hemoglobin is a protein that transports oxygen in red blood cells and is of great significance to human life activities [1]. Flap grafting is a relatively common method of skin grafting in the medical community. Flap is transfered from the flap area to the receptor, establishing a new blood supply, and guaranteeing normal blood supply to the wounded area [2]. During the entire recovery process, real-time monitoring of the growth status of the flaps is required. The hemoglobin concentration, as an important index to measure the growth status, can mainly reflect the state of blood circulation. Therefore, it is quite necessary to achieve a convenient and accurate measurement of hemoglobin concentration in the skin graft site.

Select All
1.
Li Gang, Bao Lei, Zhou Mei, Lin Ling, Liu Rui and Zhao Chunjie, "A new method for measuring oxygen saturation in arterial blood", Spectroscopy and Spectral Analysis, vol. 36, pp. 196-200, 2016.
2.
Zhang Juan and Song Baoqiang, "Research progress of blood supply monitoring after free flap transplantation", Modern Biomedicine, vol. 14, pp. 3589-3592, 2014.
3.
Han Dong and Chen Chuanjun, "Experimental study on the dynamic monitoring of vascular crisis after free flap transplantation by percutaneous oxygen saturation measurement", Chinese Journal of Clinical Healthcare, pp. 611-613, 2007.
4.
Jiang Wenfeng, Liu Li and Fan Guilian, "Clinical observation and nursing of skin flap transplantation", Nursing practice and research, vol. 7, pp. 62-63, 2010.
5.
Liu Guangwei, Mao Luhong, Xie Sheng, Meng Qingbin and Zhang Qingrong, "A photoelectric reflection pulse oximetry method", Optoelectronics Laser, vol. 25, pp. 620-624, 2014.
6.
Fang Lei, "Design and implementation of non-invasive blood oxygen saturation measurement system", Huazhong University of Science and Technology, 2012.
7.
Wang Xiaofei and Zhao Wenjun, "Measurement of multi-wavelength pulse oximetry based on dynamic spectroscopy", Spectroscopy and Spectral Analysis, vol. 34, pp. 1323-1326, 2014.