Abstract:
A power amplifier is used to supply sinusoidal currents of different frequencies for measuring eddy-current losses of a 25 kVA single-phase transformer under short-circui...Show MoreMetadata
Abstract:
A power amplifier is used to supply sinusoidal currents of different frequencies for measuring eddy-current losses of a 25 kVA single-phase transformer under short-circuit condition. Measured data show that eddy-current loss is a linear function of frequency with power of 2 and the eddy-current loss coefficient P/sub EC-Rlinear/ is computed. New measurement techniques are applied to determine the derating of single-phase transformers with full-wave diode and thyristor rectifier loads. The derating of transformers has been defined such that for the (apparent, real) power transfer of a transformer the total losses are identical to the rated losses at rated temperature. A relation between apparent power, derating and K-factor is given taking into account iron-core and stray-power losses. Measured derating values are compared with computed results based on the eddy-current losses, iron-core losses, stray-power losses, and K-factors. The eddy-current loss coefficient P/sub EC-Rnonlinear/ is computed from harmonics caused by diode/thyristor bridge loads.
Published in: IEEE Transactions on Power Delivery ( Volume: 15, Issue: 1, January 2000)
DOI: 10.1109/61.847243
References is not available for this document.
Select All
1.
E. F. Fuchs and R. Fei, "A new computer-aided method for the efficiency measurement of low-loss transformers and inductors under nonsinusoidal operation", IEEE Trans. on Power Delivery, vol. PWRD-11, no. 1, pp. 292-304, Jan. 1996.
2.
D. Lin, E. F. Fuchs and M. Doyle, "Computer-aided testing of electrical apparatus supplying nonlinear loads", IEEE Trans. on Power Systems, vol. 12, no. 1, pp. 11-21, Feb. 1997.
3.
"Standard UL 1561", Dry-Type General Purpose and Power Transformers, Apr. 1994.
4.
L. W. Pierce, "Transformer design and application considerations for nonsinusoidal load currents", IEEE Trans. on Industry Applications, vol. 32, no. 3, pp. 633-645, May/June 1996.
5.
"Standard UL 1562", Transformers Distribution Dry Type Over 600 Volts, Jan. 1994.
6.
IEEE Standard Dictionary of Electrical and Electronics Terms.
7.
"ANSI/IEEE Standard C57.110", Establishing Transformer Capability When Supplying Nonsinusoidal Load Currents, Mar. 1998.
8.
C. K. Duffey and R. P. Stratford, "Update of harmonic standard IEEE-519: IEEE recommended practices and requirements for harmonic control in electric power systems", IEEE Trans. on Ind. Applications, vol. 25, no. 6, Nov./Dec. 1989.
9.
E. F. Fuchs, D. J. Roesler and K. P. Kovacs, "Aging of electrical appliances due to harmonics of the power system's voltage", IEEE Trans. on Power Delivery, vol. PWRD-1, no. 3, pp. 301-307, July 1986.
10.
T. Batan, Real-time monitoring and calculation of the derating of single-phase transformers under (non)sinusoidal operations, Dec. 1998.
11.
A. W. Galli and M. D. Cox, "Temperature rise of small oil-filled distribution transformers supplying nonsinusoidal load currents", IEEE Trans. on Power Delivery, vol. 11, no. 1, pp. 283-291, Jan. 1996.
12.
M. T. Bishop, J. F. Baranowski, D. Heath and S. J. Benna, "Evaluating harmonic-induced transformer heating", IEEE Trans. on Power Delivery, vol. 11, no. 1, pp. 305-311, Jan. 1996.
13.
T. D. Stensland, E. F. Fuchs, W. M. Grady and M. T. Doyle, "Modeling of magnetizing and core-loss currents in single-phase transformers with voltage harmonics for use in power flow", IEEE Trans. on Power Delivery, vol. 12, no. 2, pp. 768-774, Apr. 1997.
14.
E. F. Fuchs, T. D. Stensland, W. M. Grady and M. T. Doyle, "Measurement of harmonic losses of pole transformers and single-phase induction motors", Proceedings of the IEEE-IAS Industry Applications Society Annual Meeting, pp. 128-134, 1994-Oct.-2’.
15.
"ANSI/IEEE Standard C57.18.10-1998", Standard Practices and Requirements for Semiconductor Rectifier Transformers.