Abstract:
Transformers are equipment designed to operate perfectly at linear loads. Nowadays with wide use of modern technology requirement and industry needs which utilize nonline...Show MoreMetadata
Abstract:
Transformers are equipment designed to operate perfectly at linear loads. Nowadays with wide use of modern technology requirement and industry needs which utilize nonlinear loads, the transformers are subjected to more nonlinear loads. Many research studied the influence of harmonics upon transformers. This paper focuses on transformer losses calculations for the case study of Mubarak Pumping Station (MPS) with and without passive harmonic filters. Also harmonic indices including K-Factor transformer, Total Harmonic Distortion (THD), Harmonic Loss Factor (FHL) and de-rating of transformer are calculated. When distribution transformer is operating under harmonic load, the value of load losses is increased, while the no load losses increased with a little amount. No load losses of a distribution transformer under harmonic loads can increase its operating cost. K-Factor calculation depends upon the fundamental current and the harmonic current components, and it is an indicative value of the harmonic contents in the power system.
Date of Conference: 27-29 December 2016
Date Added to IEEE Xplore: 02 February 2017
ISBN Information:
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Transformer Loss ,
- Loss Value ,
- Power Conditions ,
- Harmonic Components ,
- Harmonic Distortion ,
- Total Harmonic Distortion ,
- Copper Loss ,
- Current Harmonics ,
- Harmonic Content ,
- Nonlinear Load ,
- Passive Filter ,
- Linear Load ,
- Maximum Density ,
- Reduction In Capacity ,
- Eddy Current ,
- Proximity Effect ,
- Maximum Loss ,
- Load Current ,
- Eddy Current Loss ,
- Harmonic Voltage ,
- Transformation Operations ,
- Current Loss ,
- Skin Depth ,
- Loss Of Density ,
- Hysteresis Loss ,
- Sinusoidal Load ,
- IEEE Standard ,
- Synchronous Motor
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Transformer Loss ,
- Loss Value ,
- Power Conditions ,
- Harmonic Components ,
- Harmonic Distortion ,
- Total Harmonic Distortion ,
- Copper Loss ,
- Current Harmonics ,
- Harmonic Content ,
- Nonlinear Load ,
- Passive Filter ,
- Linear Load ,
- Maximum Density ,
- Reduction In Capacity ,
- Eddy Current ,
- Proximity Effect ,
- Maximum Loss ,
- Load Current ,
- Eddy Current Loss ,
- Harmonic Voltage ,
- Transformation Operations ,
- Current Loss ,
- Skin Depth ,
- Loss Of Density ,
- Hysteresis Loss ,
- Sinusoidal Load ,
- IEEE Standard ,
- Synchronous Motor
- Author Keywords