Abstract:
When a ground fault occurs at a substation, the part of the fault current that flows between the grounding system and the surrounding earth is known as grid current. This...Show MoreMetadata
Abstract:
When a ground fault occurs at a substation, the part of the fault current that flows between the grounding system and the surrounding earth is known as grid current. This current determines the magnitude of the dangerous voltages within and around the station. It may vary from a few percent to almost 100% of the earth fault current. It is necessary to make an accurate estimate of grid current for an economical and safe design of ground electrode. The available analytical methods for determining the grid current require complete system data, which is voluminous and often unavailable. In this paper a simple and accurate analytical method for determining the grid current is presented. The method requires limited data. A computer program based on the proposed method has been developed and tested.
Published in: IEEE Transactions on Power Delivery ( Volume: 14, Issue: 3, July 1999)
DOI: 10.1109/61.772331
References is not available for this document.
Select All
1.
J. Endrenyi, "Analysis of Transmission Tower Potentials During Ground Faults", IEEE Transactions on Power Apparatus and Systems, vol. PAS-86, no. 10, pp. 1274-1283, Oct. 1967.
2.
S. Sebo, "Zero Sequence Current Distribution Along Transmission Lines", IEEE Transactions on Power Apparatus and Systems, vol. PAS-88, no. 6, pp. 910-919, June 1969.
3.
R. Varma and D Mukhedkar, "Ground Fault Current Distribution in Substation Towers and Ground Wire", IEEE Transactions on Power Apparatus and Systems, vol. PAS-98, no. 3, pp. 724-730, May/June 1979.
4.
A. Meliopoulos, R. Webb, E. Joy and S. Patel, "Computation of Maximum Earth Current in Substation Switchyards", IEEE Transactions on Power Apparatus and Systems, vol. PAS-102, no. 9, pp. 3131-3139, Sept. 1983.
5.
Analysis Technique for Power Substation Grounding Systems, USA, Palo Alto:Electric Power Research Institute, vol. 1 and 2, October 1982.
6.
F. Dawalibi, M. Bouchard and D. Mukhedkar, "Survey on Power System Grounding Design Practices", IEEE Transactions on Power Apparatus and Systems, vol. PAS-99, no. 4, pp. 1396-1405, July/August 1980.
7.
S. K. Madan, Current for Design of Grounding Grids in Substations, 1982.
8.
B. Thapar and S. K. Madan, "Current for Design of Grounding Systems", IEEE Transactions on Power Apparatus and Systems, vol. PAS-103, pp. 2633-2637, Sept. 1984.
9.
D. L. Garett, "3", IEEE Tutorial Course - Practical Applications of ANSI / IEEE Standard 80 - 1986 IEEE Guide for Safety, pp. 23-39.
10.
IEEE Guide for Safety in AC Substation Grounding, 1986.
11.
M. E. Van Valkenburg, Network Analysis, New Delhi:Prentice Hall of India Pvt. Ltd., 1984.
12.
C. F. Wagner and R. D. Evans, Symmetrical Components, New York:McGraw-Hill Book Company Inc., 1933.
13.