Loading [MathJax]/extensions/MathZoom.js
Investigation of a fuel cell system operating in stand alone and grid connected mode | IEEE Conference Publication | IEEE Xplore

Investigation of a fuel cell system operating in stand alone and grid connected mode


Abstract:

This paper intends to investigate the operation of a proton exchange membrane fuel cell system (PEMFC) under stand alone and grid connected operation mode when it is subj...Show More

Abstract:

This paper intends to investigate the operation of a proton exchange membrane fuel cell system (PEMFC) under stand alone and grid connected operation mode when it is subjected to dynamic disturbance at the point of common coupling (PCC) in a distributed generation (DG) system. Monitoring of critical parameters in the system such as active power delivered by the system, PCC side frequency, anode channel pressure of PEMFC are the main parameters of interest. It is inferred that capability of the controller for voltage source inverter (VSI) used as an interfacing medium between the PEMFC system and PCC is critical for proper functioning of the fuel cell system as a whole. The critical aspects required for functioning of the system under both the modes, viz. stand alone and grid connected are brought out via simulation platform.
Date of Conference: 17-20 December 2015
Date Added to IEEE Xplore: 31 March 2016
ISBN Information:
Electronic ISSN: 2325-9418
Conference Location: New Delhi, India

I. Introduction

Emergence of fuel cell system is one of the promising solutions for meeting the power demand for residential and industrial users. Fuel cell systems are characterized by various advantageous features [1] like high efficiency, pollution free operation (for systems without reformer), modularity, portability, noise free operation etc., hence design and modeling of a fuel cell system especially PEMFC motivates to take up the present work. Operation of a fuel cell based DG systems demands for reliable operation since, any form of electrical load transients or balanced and unbalanced faults (referred as contingency) can lead to damage in PEMFC module especially the costly membrane responsible for splitting of the hydrogen proton and electron. Further, if the above contingencies are not handled then there might be high current flow through the inverter which could be above the rated limit, resulting in damage of inverter switches [2], [3]. Thus, investigation of a PEMFC based DG system (Fig. 1) under contingency is another motivating objective in the work presented. It is well known, for situations where access to utility grid is a major constrain, their stand alone systems are preferred [2], [4]. For conditions when power generated from DG sources is abundant, then surplus power is fed to utility grid resulting for requirement of grid connected operation [5], [7]. Hence, the paper considers two operating modes namely, stand alone mode and grid connected mode for investigation purpose.

Contact IEEE to Subscribe

References

References is not available for this document.