Abstract:
Inter-laminar short circuit faults between laminations of the magnetic cores increase core losses and could cause major damage to electrical machines. In this paper, firs...Show MoreMetadata
Abstract:
Inter-laminar short circuit faults between laminations of the magnetic cores increase core losses and could cause major damage to electrical machines. In this paper, first causes and consequences of inter-laminar faults in magnetic cores are presented. Different types of inter-laminar fault detection methods are then presented and discussed. In the relevant studies, advantages and disadvantages of each method is highlighted. Finally, experimental results of an electro-magnetic fault detection method based on Flux Injection Probe is presented.
Date of Conference: 01-04 September 2015
Date Added to IEEE Xplore: 03 December 2015
ISBN Information: