Abstract:
After conception and implementation of any new medical image processing algorithm, validation is an important step to ensure that the procedure fulfils all requirements s...Show MoreMetadata
Abstract:
After conception and implementation of any new medical image processing algorithm, validation is an important step to ensure that the procedure fulfils all requirements set forth at the initial design stage. Although the algorithm must be evaluated on real data, a comprehensive validation requires the additional use of simulated data since it is impossible to establish ground truth with in vivo data. Experiments with simulated data permit controlled evaluation over a wide range of conditions (e.g., different levels of noise, contrast, intensity artefacts, or geometric distortion). Such considerations have become increasingly important with the rapid growth of neuroimaging, i.e., computational analysis of brain structure and function using brain scanning methods such as positron emission tomography and magnetic resonance imaging. Since simple objects such as ellipsoids or parallelepipedes do not reflect the complexity of natural brain anatomy, the authors present the design and creation of a realistic, high-resolution, digital, volumetric phantom of the human brain. This three-dimensional digital brain phantom is made up of ten volumetric data sets that define the spatial distribution for different tissues (e.g., grey matter, white matter, muscle, skin, etc.), where voxel intensity is proportional to the fraction of tissue within the voxel. The digital brain phantom can be used to simulate tomographic images of the head. Since the contribution of each tissue type to each voxel in the brain phantom is known, it can be used as the gold standard to test analysis algorithms such as classification procedures which seek to identify the tissue "type" of each image voxel. Furthermore, since the same anatomical phantom may be used to drive simulators for different modalities, it is the ideal tool to test intermodality registration algorithms. The brain phantom and simulated MR images have been made publicly available on the Internet (http://www.bic.mni.mcgill.ca/brainweb).
Published in: IEEE Transactions on Medical Imaging ( Volume: 17, Issue: 3, June 1998)
DOI: 10.1109/42.712135
References is not available for this document.
Select All
1.
"A quantitative comparison of residual error for three different multimodality registration techniques", Information Processing in Medical Imaging, pp. 251-262, 1995.
2.
J. C. Rajapakse, C. DeCarli, A. McLaughlin, J. N. Giedd, A. L. Krain, S. D. Hamburger, et al., "Cerebral magnetic resonance image segmentation using data fusion", J. Comput. Assist. Tomogr., vol. 20, pp. 206-18, Mar./Apr. 1996.
3.
E. Hoffman, P. Cutler, W. Digby and J. Mazziotta, "3-D phantom to simulate cerebral blood flow and metabolic images for PET", IEEE Trans. Nucl. Sci., vol. 37, pp. 616-620, 1990.
4.
E. Hoffman, P. Cutler, T. Guerrero, W. Digby and J. Mazziotta, "Assessment of accuracy of PET utilizing a 3-D phantom to simulate the activity distribution of FDG uptake in the human brain", J. Cereb. Blood Flow Metab., vol. 11, pp. A17-A25, 1991.
5.
H. J. Kim, J. S. Karp, P. D. Mozley, S. O. Yang, D. H. Moon, H. F. Kung, et al., "Stimulating technetium-99 m cerebral perfusion studies with a three-dimensional Hoffmann brain phantom: Collimator and filter selection in SPECT neuroimaging", Ann. Nucl. Med., vol. 10, pp. 153-160, Feb. 1996.
6.
S. Eberl, I. Kanno, R. R. Fulton, A. Ryan, B. F. Hutton and M. J. Fulham, "Automated interstudy image registration technique for SPECT and pet", J. Nucl. Med., vol. 37, pp. 137-45, Jan. 1996.
7.
J. Li, R. J. Jaszczak and R. E. Coleman, "A filtered backprojection algorithm for axial head motion correction in fan-beam SPECT", Phy. Med. Biol., vol. 40, pp. 2053-2063, Dec. 1995.
8.
D. Mahoney, S. Huang, A. Ricci, J. Mazziotta, R. Carson, E. Hoffman, et al., "A realistic computer-simulated brain phantom for evaluation of PET characteristics", IEEE Trans. Med. Imag., vol. MI-6, pp. 250-257, 1987.
9.
H.-J. Kim, B. Zeeberg, F. Fahey, A. Bice, E. Hoffman and R. Reba, "3-D SPECT simulations of a complex 3-D mathematical brain model and measurements of the 3-D physical brain phantom", J. Nucl. Med., vol. 32, pp. 1923-1930, 1991.
10.
Y. Narita, H. Iida, B. A. Ardekani, J. Hatazawa, I. Kanno, T. Nakamura, et al., "Evaluation of partial volume effect in quantitative measurement of regional cerebral blood flow using positron emission tomography", Kaku IgakuJpn. J. Nucl. Med., vol. 32, pp. 163-72, Feb. 1995.
11.
H. Iida, Y. Narita, B. A. Ardekani, J. Hatazawa, M. Nakazawa, I. Kanno, et al., "Evaluation of partial volume effect in quantitative measurement of regional cerebral blood flow in single photon emission computed tomography-effects of limited spatial resolution and first-pass extraction fraction", Kaku IgakuJpn. J. Nucl. Med., vol. 32, pp. 155-62, Feb. 1995.
12.
D. Collins, C. Holmes, T. Peters and A. Evans, "Automatic 3-D model-based neuroanatomical segmentation", Human Brain Mapping, vol. 3, no. 3, pp. 190-208, 1995.
13.
Y. Ma, M. Kamber and A. C. Evans, "3-D simulation of PET brain images using segmented MRI data and positron tomograph characteristics", Computerized Med. Imag. Graphics, vol. 17, pp. 365-371, July/Oct. 1993.
14.
R. Kwan, A. C. Evans and G. B. Pike, "An extensible MRI simulator for post-processing evaluation", Proc. 4th Int. Conf. Visualization in Biomedical Computing VBC `96, pp. 135-140, Sept. 1996.
15.
C. Holmes, R. Hoge, D. Collins, R. Woods, A. Toga and A. Evans, "Enhancement of MR images using registration for signal averaging", J. Comput. Assist. Tomogr., vol. 22, pp. 324-333, Mar. 1998.
16.
J. Talairach and P. Tournoux, Co-Planar Stereotactic Atlas of the Human Brain: 3-Dimensional Proportional System: An Approach to Cerebral Imaging, 1988.
17.
D. L. Collins, P. Neelin, T. M. Peters and A. C. Evans, "Automatic 3-D inter-subject registration of MR volumetric data in standardized Talairach space", J. Comput. Assist. Tomogr., vol. 18, pp. 192-205, Mar./Apr. 1994.
18.
J. G. Sled, A. P. Zijdenbos and A. C. Evans, "A nonparametric method for automatic correction of intensity nonuniformity in MRI data", IEEE Trans. Med. Imag., vol. 17, Feb. 1998.
19.
R. Duda and P. Hart, Pattern Recognition And Scene Analysis, 1973.
20.
J. Bezdek, Pattern Recognition with Fuzzy Objective Function Algorithms, 1981.
21.
J. M. Zurada, Introduction to Artificial Neural Systems, 1992.
22.
V. Kollokian, Performance analysis of automatic techniques for tissue classification in MRI of the human brain, Nov. 1996.
23.
R.-S. Kwan, A. Evans and G. Pike, "fMRI simulation for quantitative evaluation of analysis methods", NeuroImage, vol. 5, pp. S449, May 1997.
24.
C. Cocosco, V. Kollokian, R.-S. Kwan and A. Evans, "Brainweb: Online interface to a 3-D MRI simulated brain database", NeuroImage, vol. 5, pp. S425, May 1997.