Ejecta experiments at the Pegasus pulsed power facility | IEEE Conference Publication | IEEE Xplore

Ejecta experiments at the Pegasus pulsed power facility


Abstract:

When a shock wave interacts at the surface of a metal sample "ejected matter" (ejecta) can be emitted from the surface at velocities larger than the sample velocity. The ...Show More

Abstract:

When a shock wave interacts at the surface of a metal sample "ejected matter" (ejecta) can be emitted from the surface at velocities larger than the sample velocity. The mass, size, shape, and velocity of ejecta varies depending on the initial shock conditions and the target's material properties. In order to understand this phenomena, diagnostics have been developed and implemented at the Pegasus Pulsed Power Facility (PPPF) located at Los Alamos National Laboratory (LANL). The facility provides both radial and axial access for making measurements. There exist optical, laser, and X-Ray paths for performing measurements on the target assembly located near the center of the machine. The facility can provide many mega-amps of current which are transported to a 5.0-cm diameter, 2.0-cm high aluminum cylinder. The current and associated magnetic field set up forces which implode the aluminum cylinder radially inward. As the aluminum cylinder reaches the appropriate velocity, it impacts a target cylinder. Due to this impact, a shock wave is set up in the target and eventually interacts at the inner surface of the target cylinder where ejecta are produced. A 1.5-cm diameter collimator cylinder located in the target cylinder is used to control the number of ejecta particles that arrive at the center region where ejecta measurements are made. Two diagnostic techniques for characterizing ejecta, inline Fraunhofer holography and visible shadowgraphy are detailed in this report.
Date of Conference: 29 June 1997 - 02 July 1997
Date Added to IEEE Xplore: 06 August 2002
Print ISBN:0-7803-4213-5
Conference Location: Baltimore, MD, USA
References is not available for this document.

Select All
1.
P. Andriot, P. Chapron, V. Lambert and F. Olive, "Influence of Melting on Shocked Free Surface Behavior using Doppler Laser Interferometry and X-Ray Densitometry" in Shock Waves in Condensed Matter, Elsevier Science Publishers B.B., pp. 277, 1983.
2.
J. R. Assay, Material Ejection from Shock-Loaded Free Surfaces of Aluminum and Lead, 1976.
3.
P. Elias, P. Chapron and M. Mondot, "Experimental study of the slowing down of shock-induced matter ejection into argon gas" in Shock Compression in Condensed Matter 1989, Elsevier Science Publishers B.B., pp. 783, 1990.
4.
C. McMillan and R. Whipley, Proceedings of the 18th International Congress on High-Speed Photography and Photonics, 1988.
5.
C. F. McMillan, "Size measurements of high velocity particle distributions", SPIE 674 High Speed Photography, pp. 289, 1986.
6.
P. Andriot, P. Chapron and F. Olive, "Ejection of material from shocked surfaces of tin tantalum and lead alloys", Shock Waves in Condensed Matter 81 AIP Conf. Proc., vol. N78, pp. 505, 1981.
7.
J. L. Stokes, "Precision current measurements on Pegasus II using Faraday rotation", Proceedings of the 10th IEEE Pulsed Power Conference, pp. 378, 1995.
8.
L. R. Veeser, G. I. Chandler and G. W. Day, "Fiber optic sensing of pulsed currents", SPIE 648, pp. 197, 1986.
9.
D. Platts, M. P. Hockaday, D. Beck, W. Coulter and R. C. Smith, "Compact Flash X-Ray units", Proceedings of the 10th IEEE Pulsed Power Conference, pp. 892, 1995.
10.
D. S. Sorenson, "Particle Distribution Measurements Using In-Line Fraunhofer Holography", Proceedings of the 22nd International Congress on High-Speed Photography and Photonics ICHSPP'96, pp. 206, 1996.
11.
D. S. Sorenson, "In-Line Particle Field Holography at Pegasus", Proceedings of the 10th IEEE Pulsed Power Conference, pp. 1024, 1995.
12.
C. S. Vikram, Particle Field Holography, Cambridge Studies in Modern Optics, 1992.
Contact IEEE to Subscribe

References

References is not available for this document.