Transmission line parameter is important for obtaining power network structure, generating power system node admittance matrix or impedance matrix to calculate power flow...Show MoreMetadata
Abstract:
Transmission line parameter is important for obtaining power network structure, generating power system node admittance matrix or impedance matrix to calculate power flow, calculating short-circuit current, and setting relaying protection devices. But actually, transmission line parameters applied in power system are mostly experience values or offline measuring values provided by manufacturers, they may quite different from real parameters. This will influence the precision of power system analysis and calculation. This paper studies online calculation methods of transmission line parameters based on phasor and sampling value, it can calculate positive sequence parameters and also negative sequence, zero sequence parameters to improve the accuracy of fault analysis and relay protection settings. Different types of transmission line models are built by PSCAD to test and verify the calculation methods, results show that the proposed methods for transmission line parameters online calculation have high accuracy and reliability, they can provide reliable basis for power flow calculation, protection setting, operation reliability and safety of power grid.
Published in: 11th IET International Conference on Developments in Power Systems Protection (DPSP 2012)
Date of Conference: 23-26 April 2012
Date Added to IEEE Xplore: 05 July 2012
Print ISBN:978-1-84919-620-8
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Transmission Line ,
- Line Parameters ,
- Transmission Line Parameters ,
- Accurate Analysis ,
- Power System ,
- Positive Parameter ,
- Phase Values ,
- Sequence Parameters ,
- Positive Sequence ,
- Negative Sequence ,
- Impedance Matrix ,
- Transmission Line Model ,
- Admittance Matrix ,
- Zero Sequence ,
- Relay Protection ,
- Power System Analysis ,
- Model Parameters ,
- Equivalent Circuit ,
- Line Length ,
- Electrical Parameters
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Transmission Line ,
- Line Parameters ,
- Transmission Line Parameters ,
- Accurate Analysis ,
- Power System ,
- Positive Parameter ,
- Phase Values ,
- Sequence Parameters ,
- Positive Sequence ,
- Negative Sequence ,
- Impedance Matrix ,
- Transmission Line Model ,
- Admittance Matrix ,
- Zero Sequence ,
- Relay Protection ,
- Power System Analysis ,
- Model Parameters ,
- Equivalent Circuit ,
- Line Length ,
- Electrical Parameters
- Author Keywords