Loading [MathJax]/extensions/MathMenu.js
Thin detectors for the CHICSi /spl Delta/E-E telescope | IEEE Journals & Magazine | IEEE Xplore

Thin detectors for the CHICSi /spl Delta/E-E telescope


Abstract:

A pilot series of 10 /spl mu/m to 15 /spl mu/m thin silicon detectors has been made for the /spl Delta/E-E telescopes in the CHICSi detector system. This system will oper...Show More

Abstract:

A pilot series of 10 /spl mu/m to 15 /spl mu/m thin silicon detectors has been made for the /spl Delta/E-E telescopes in the CHICSi detector system. This system will operate at the CELSIUS heavy ion storage ring in Uppsala, Sweden. /spl Delta/E-E telescopes provide isotope identification and energy determination of fragments from nuclear collisions. The thin detectors are made as p-i-n diodes in thin etched membranes in 280 /spl mu/m thick silicon wafers. The membranes are made with anisotropic etching using 25 wt.% tetramethylammonium hydroxide (TMAH) solution. The etch speed of this solution is very uniform across a wafer. As a result detectors with uniform thickness can be produced. The etch depth varies with less than /spl plusmn/0.3 /spl mu/m over a wafer and the surface microroughness is in the range from 2 to 4 nm. Each detector has a 10.0 mm/spl times/10.0 mm active area on a 10.2 mm/spl times/10.2 mm membrane surrounded by a 1.1 mm wide supporting frame. The detectors have leakage currents in the active area of approximately 0.5 nA at 20 V. The breakdown voltage of the detectors is above 100 V. Evaluation experiments with telescopes consisting of a thin detector in combination with a thick detector have shown excellent isotope separation capabilities. Mass separation of /sup 6/Li and /sup 7/Li is clearly observable.
Published in: IEEE Transactions on Nuclear Science ( Volume: 44, Issue: 3, June 1997)
Page(s): 629 - 634
Date of Publication: 30 June 1997

ISSN Information:

References is not available for this document.

Select All
1.
A. G. Seamster, R. E. L. Green and R. G. Korteling, "Silicon detector ΔΕ E particle identification: A theoretically based analysis algorithm and remarks on the fundamental limits to the resolution of particle type by ΔΕ E measurements", Nucl. Instr. and Meth., vol. 145, pp. 583-591, 1977.
2.
L. Evensen, "Feasibility of thin detectors", Proceedings of the ECFA study week on instrumentation for high luminosity colliders, vol. 1, pp. 351-355, 1989-September.
3.
L. Lavergne-Gosselin, "On the use of thin ion implanted Si detectors in heavy ion experiments", Nucl. Instr. and Meth., vol. A276, pp. 210-215, 1989.
4.
L. Stab, "Thin epitaxial silicon detectors", Nucl. Instr. and Meth., vol. A288, pp. 24-30, 1990.
5.
B. Schmidt, J. von Borany and D. Schubert, "Application of wet chemical selective etching to the fabrication of thin silicon detectors", Nucl. Instr. and Meth., vol. A326, pp. 21-26, 1993.
6.
H. Seidel, "Anisotropic etching of crystalline silicon in alkaline solutions", J. Electrochem. Soc., vol. 137, pp. 3612-3632, November 1990.
7.
O. Tabata, "Anisotropic etching of silicon in TMAH solutions", Sensors and Actuators A, vol. 34, pp. 51-57, 1992.
8.
B. S. Avset and L. Evensen, "The effect of metal field plates on multiguard structures with floating p+ guard rings", Nucl. Instr. and Meth., vol. A377, pp. 397-403, 1996.
9.
CHICSi - A proposal for a multi-detector ΔΕ-Ε particle telescope, 1993.