Abstract:
A new RF system for improving both the proton and antiproton bunch coalescing efficiencies has been installed in the Fermilab Main Ring. The system consists of five, ferr...Show MoreMetadata
Abstract:
A new RF system for improving both the proton and antiproton bunch coalescing efficiencies has been installed in the Fermilab Main Ring. The system consists of five, ferrite-loaded RF cavities operating at a fixed frequency of 2.5 MHz and a second harmonic cavity at 5.0 MHz. Each cavity is driven by a 5 kW solid-state power amplifier and can produce a peak accelerating gap voltage greater than 15 kV. An overview of the entire system will be presented along with a detailed description of the RF cavity design including ferrite selection and testing procedures.
Published in: Proceedings Particle Accelerator Conference
Date of Conference: 01-05 May 1995
Date Added to IEEE Xplore: 06 August 2002