Abstract:
The leakage current (I/sub L/) annealing at elevated temperatures and the corresponding changes of the DLTS spectra of defects for fast neutron irradiated silicon detecto...Show MoreMetadata
Abstract:
The leakage current (I/sub L/) annealing at elevated temperatures and the corresponding changes of the DLTS spectra of defects for fast neutron irradiated silicon detectors, fabricated on high (4-6 k/spl Omega/-cm), moderate (0.5-1.0 k/spl Omega/-cm), and low (<100 /spl Omega/-cm) resistivity silicon material, have been investigated. For all the resistivities, three annealing stages have been observed: (1) the transformation of carbon related defects at 72/spl deg/C; (2) slight decrease of the peak E/sub c/-0.4 eV at 150/spl deg/C, and (3) significant decrease of the peak E/sub c/-0.4 eV at 350/spl deg/C. The leakage current has been found to decrease monotonously in the temperature range of 20-150/spl deg/C. A sharp decrease of I/sub L/ was observed at 350/spl deg/C due to the annealing of the V-V center for heavily irradiated detectors, whereas I/sub L/ showed a slight saturation tendency for detectors irradiated to low neutron fluence. The V-V center has been found to be dominant in the formation of the E/sub c/-0.4 eV peak and in the annealing of the leakage current. For low resistivity detectors, an anneal at 72/spl deg/C was needed to stimulate the decrease of the effective impurity concentration (N/sub eff/) of the detectors irradiated by high neutron fluence (1-2)/spl times/10/sup 14/ n/cm/sup 2/. In addition, low resistivity detectors have been found to be tolerant in terms of N/sub eff/ stability to the 350/spl deg/C anneal, favorable to the recovery of I/sub L/ after irradiation with high neutron fluence.<>
Date of Conference: 30 October 1994 - 05 November 1994
Date Added to IEEE Xplore: 06 August 2002
Print ISBN:0-7803-2544-3
References is not available for this document.
Select All
1.
R. Wunstorf, M. Benkert, N. Claussen, N. Croitoru, E. Fretwurst, G. Lindstrom, et al., "Results on Radiation Hardness of Silicon Detectors up to Neutron Fluence of 1015n/cm2", Nucl. Instr. Meths., vol. A315, pp. 149, 1992.
2.
K. Gill, G. Hall, S. Roe, S. Sotthibandhu, R. Wheadon, P. Giubellino, et al., "Radiation Damage by Neutrons and Photons to Silicon Detectors", Nucl. Instr. Meths., vol. A322, pp. 177, 1992.
3.
H. J. Ziock, J. G. Boissevain, K. Holzscheiter, J. S. Kapustinsky, A. P. T. Palounek, W. E. Sondheim, et al., "Temperature Dependence of Radiation Damage and Its Annealing in Silicon Detectors", IEEE Trans. Nucl. Sci., vol. 40, no. 4, pp. 344, 1993.
4.
Z. Li, "Modeling and Simulation of Neutron Induced Changes and Temperature Annealing of Neff and Changes in Resistivity in High Resistivity Silicon Detectors", International Symposium on Development and Application of Semiconductor Tracking Detectors, 1993-May-22-24.
5.
Z. Li, Investigation on the Long-term Radiation Hardness of Low Resistivity Starting Materials for RT Silicon Detectors in High Energy Physics.
6.
V. Eremin, A. Ivanov, N. Strokan, Verbiskaya, Z. Li and B. Schmidt, "Relaxation of Radiation Damages in Silicon Planar Detectors", 1st International Conference on Large Scale Applications and Radiation Hardness of Semiconductors, 1993-July-7-9.