An Evaluation of a Non-contact Biomotion Sensor with Actimetry | IEEE Conference Publication | IEEE Xplore

An Evaluation of a Non-contact Biomotion Sensor with Actimetry


Abstract:

Actimetry is a widely accepted technology for the diagnosis and monitoring of sleep disorders such as insomnia, circadian sleep/wake disturbance, and periodic leg movemen...Show More

Abstract:

Actimetry is a widely accepted technology for the diagnosis and monitoring of sleep disorders such as insomnia, circadian sleep/wake disturbance, and periodic leg movement. In this study we investigate a very sensitive non-contact biomotion sensor to measure actimetry and compare its performance to wrist-actimetry. A data corpus consisting of twenty subjects (ten normals, ten with sleep disorders) was collected in the unconstrained home environment with simultaneous non-contact sensor and ActiWatch actimetry recordings. The aggregated length of the data is 151 hours. The non-contact sensor signal was mapped to actimetry using 30 second epochs and the level of agreement with the ActiWatch actimetry determined. Across all twenty subjects, the sensitivity and specificity was 79% and 75% respectively. In addition, it was shown that the non-contact sensor can also measure breathing and breathing modulations. The results of this study indicate that the non-contact sensor may be a highly convenient alternative to wrist-actimetry as a diagnosis and screening tool for sleep studies. Furthermore, as the non- contact sensor measures breathing modulations, it can additionally be used to screen for respiratory disturbances in sleep caused by sleep apnea and COPD.
Date of Conference: 22-26 August 2007
Date Added to IEEE Xplore: 22 October 2007
ISBN Information:

ISSN Information:

PubMed ID: 18002543
Conference Location: Lyon, France
No metrics found for this document.

I. Introduction

SLEEP assessment can be based on many different types of signals. Existing methods to measure these signals, including polysomnography (PSG), actigraphy, and sleep diaries. PSG, the gold standard for sleep assessment, may be impractical for some applications, particularly for usage in the home. It can be both intrusive and expensive.

Usage
Select a Year
2025

View as

Total usage sinceJan 2011:506
0246810JanFebMarAprMayJunJulAugSepOctNovDec084000000000
Year Total:12
Data is updated monthly. Usage includes PDF downloads and HTML views.
Contact IEEE to Subscribe

References

References is not available for this document.