A miniature dissolved oxygen sensor is fabricated using photolithographic reduction and thick-film metallization techniques. This sensor has a multiple-cathode configurat...Show More

Abstract:

A miniature dissolved oxygen sensor is fabricated using photolithographic reduction and thick-film metallization techniques. This sensor has a multiple-cathode configuration and is operated in a three-electrode potentiostatic mode. Evaluation of the sensor characteristics was undertaken and the results are promising. Calibration of the sensor over the oxygen concentration range of 1.14-8.22 ppm (~23-160 mmHg P02) shows a good linear relationship between the reducing current of the sensor and the dissolved oxygen concentration in physiologic saline solution. The current output of the sensor is temperature dependent and is approximately 2.5 percent current output per degree centigrade. The pH value in the test medium does not affect the current output of the sensor but shows an extension of the plateau region of the polarogram. Long-term testing of the sensor indicates that the sensor can be repeatedly used for up to 10 days. There is, however, a variation of ±2.5 to ±7.5 percent in sensor output from the calibration curve as compared with the initial calibration. The sensor is used without any membrane and is flow sensitive. Preliminary tests of the sensor in outdated whole biood also show good response.
Published in: IEEE Transactions on Biomedical Engineering ( Volume: BME-33, Issue: 2, February 1986)
Page(s): 108 - 112
Date of Publication: 12 March 2007

ISSN Information:

PubMed ID: 3957361
References is not available for this document.

Select All
1.
I. A. Kolthoff and J. J. Lingane, Polarography, New York:Interscience, 1952.
2.
J. Heynovsky and J. Kuta, Principles of Polarography, New York:Academic, 1966.
3.
1959.
4.
R. Huch and A. Huch, Continuous Transcutaneous Blood-Gas Monitoring, New York:Dekker, 1983.
5.
I. Fatt and R. St. Helen, "A multicathode polarographic oxygen sensor and its performance", J. Appl. Physiol., vol. 27, pp. 435-437, 1969.
6.
J. Butler and R. S. C. Cobbold, "A multicathode oxygen sensor fabricated using integrated circuit techniques", Dig. Papers 5th Can. Med. Biol. Eng. Conf., pp. 5.2a-5.2b, 1974.
7.
W. Siu and R. S. C. Cobbold, "Characterization of a multicathode polarographic oxygen electrode", Med. Biol. Eng., vol. 14, pp. 109-121, 1976.
8.
C. C. Liu, M. R. Neuman, K. L. Montana and M. C. Oberdoerster, "Miniature multiple cathode dissolved oxygen sensor for marine science applications", Marine Technol., vol. 16, pp. 468-472, 1980.
9.
C. C. Liu and M. R. Neuman, "Fabrication of miniature P02 and pH sensors using microelectronic techniques", Diabetes Care, vol. 5, pp. 275-279, 1982.
10.
A. J. Bard and L. R. Faulkner, Electrochemical Methods, New York:Wiley, 1980.
11.
M. L. Hitchman, Measurement of Dissolved Oxygen, New York:Wiley, 1978.