Abstract:
Polymer microring resonators were demonstrated for sensing biomolecules without using fluorescent labels. The microring devices, fabricated by a direct imprinting techniq...Show MoreMetadata
Abstract:
Polymer microring resonators were demonstrated for sensing biomolecules without using fluorescent labels. The microring devices, fabricated by a direct imprinting technique, possess high Q factors of /spl sim/20000. This feature provides high sensitivity and a low detection limit for biochemical sensing applications. With these properties, the devices were used to detect and quantify the biomolecules present either in a homogeneous solution that surrounds the microring waveguide (homogeneous sensing) or specifically bound on the waveguide surface (surface sensing). In the former sensing mechanism, the current devices can detect an effective index change of 10/sup -7/ refractive index units (RIU); in the latter, they can reach a detection limit of /spl sim/250 pg/mm/sup 2/ of biomolecular coverage on the microring surface. In addition, the experiments show that the devices can detect both small and large biomolecules.
Published in: IEEE Journal of Selected Topics in Quantum Electronics ( Volume: 12, Issue: 1, Jan.-Feb. 2006)
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Microring Resonators ,
- Polymer Microring ,
- Detection Limit ,
- Fluorescent Labeling ,
- Large Biomolecules ,
- Small Biomolecules ,
- Waveguide Surface ,
- Binding Sites ,
- Deionized Water ,
- Change Detection ,
- Low Loss ,
- Surface Plasmon Resonance ,
- Measured Spectra ,
- Optical Sensors ,
- Wavelength Shift ,
- Sensor Surface ,
- Resonant Cavity ,
- Resonance Wavelength ,
- Resonance Shift ,
- Quartz Crystal Microbalance ,
- Resonance Wavelength Shift ,
- Entire Loss ,
- Waveguide Core ,
- Whispering Gallery Mode ,
- Leakage Loss ,
- Bending Loss ,
- Surface Plasmon Resonance Sensor ,
- Glucose Solution ,
- Interaction Length ,
- Optical Spectra
- Author Keywords
Keywords assist with retrieval of results and provide a means to discovering other relevant content. Learn more.
- IEEE Keywords
- Index Terms
- Microring Resonators ,
- Polymer Microring ,
- Detection Limit ,
- Fluorescent Labeling ,
- Large Biomolecules ,
- Small Biomolecules ,
- Waveguide Surface ,
- Binding Sites ,
- Deionized Water ,
- Change Detection ,
- Low Loss ,
- Surface Plasmon Resonance ,
- Measured Spectra ,
- Optical Sensors ,
- Wavelength Shift ,
- Sensor Surface ,
- Resonant Cavity ,
- Resonance Wavelength ,
- Resonance Shift ,
- Quartz Crystal Microbalance ,
- Resonance Wavelength Shift ,
- Entire Loss ,
- Waveguide Core ,
- Whispering Gallery Mode ,
- Leakage Loss ,
- Bending Loss ,
- Surface Plasmon Resonance Sensor ,
- Glucose Solution ,
- Interaction Length ,
- Optical Spectra
- Author Keywords