Abstract:
Error in the direct current power method for measuring magnetic core losses mainly depends on the accurate measurement of device losses in the DC/AC inverter circuit. The...Show MoreMetadata
Abstract:
Error in the direct current power method for measuring magnetic core losses mainly depends on the accurate measurement of device losses in the DC/AC inverter circuit. The existing calibration models for measurement devices fail to reflect the effects of switch states and duty cycles, thus reducing the accuracy of the model. In this study, the operational states of the inverter circuit with different duty cycles and switch states were analyzed, and theoretical analysis was conducted on the losses of each part. Consequently, a symmetric/asymmetric PWM excitation-based calibration model for DC/AC inverter losses, considering the effects of switch transitions and duty cycles, was proposed. Experimental validation showed that the predicted losses using this model were more accurate compared to existing two-parameter and eight-parameter models.
Date of Conference: 16-18 August 2024
Date Added to IEEE Xplore: 18 March 2025
ISBN Information:
References is not available for this document.