Introduction
Haptic rendering provides the user fundamental sensory information and consequently it is crucial for effective task execution during virtual manipulation or teleoperation. Particularly, in fine manipulation the most of the interaction is located at the fingertips, thus the design of wearable devices - such as gloves and thimbles - has to comply with strict constraints: wearability, lightweight, inter-finger interference, quality and variety of the feedback.
Haptic rendering is an essential sensory pathway for manipulation in virtual manipulation and teleoperation, as it provides users with crucial sensory information involved in the task execution. In fine manipulation tasks, the majority of interaction occurs at the fingertips. Therefore, the design of wearable devices, such as gloves and thimbles, must adhere to stringent constraints, including wearability, lightweight construction, minimal inter-finger interference, high-quality and diverse feedback rendering.
The variety of tactile sensation and stimuli has led to the creation of numerous haptic devices, encompassing vibratory [1], contact orientation [2], contact force [3], area of contact [4], tangential slip [5] tactile information. [6] offers a comprehensive review of portable and wearable haptic devices.
A. Wide Bandwidth Rendering in Wearable Haptics
Prior studies aimed at optimizing the intensity and dynamics of the rendered stimuli, involving a trade-off between static force, bandwidth, and actuator size. Fingertip devices employing direct-drive miniature electromagnetic actuators successfully achieve high-quality haptic rendering through a wide spectrum of signal frequencies. However, these devices come with the drawback of either limited maximum output force or considerable mass [7] for the fingertip application.
When these miniature actuators are coupled with gear reduction, the output force can be increased [2], [5], [8], [9] with a very limited mass increment. However, this comes at the expense of significantly reducing the output bandwidth and of introducing noise in the rendering. It is due to vibrations from the gears teeth and from friction generated by the transmission mechanism. To this regard it is important to consider the significance of transients and high-frequency components in the sense of touch, as reflected in the high sensitivity of fingerpad mechanoreceptors to fast dynamic signals [10]: this dynamic sensitivity is such that there is a frequency overlap between the tactile sensory channel and the auditory channel [11]. The perception of high-frequency signals proves crucial in texture perception [12] and tele-manipulation in general [13]. Additionally, there are factors impacting the quality of the haptic rendering, such as the presence of air gaps or excessive preloading forces between the device and the fingerpad. To this regard ergonomics of the interface and proper signal transmission between the actuated parts and the fingerpad tissues are of paramount importance.
B. Pneumatic and Hydraulic Haptic Interfaces
Pneumatic and hydraulic systems represent an interesting choice for haptic feedback, particularly when paired with soft surfaces interfacing the device to the fingerpad. Introducing inherent compliance in the interface has the potential of enhancing signal transmission, addressing the challenges associated with electromagnetic actuators, such as issues related to noise and non-linear behavior.
Examples of pneumatic actuation in wearable devices were presented in [14], [15], and [16] for rendering directional tactile signals to the wrist with a soft wearable interface. In the clinical field, a pneumatic multi-fingered actuator was proposed in [17] for remote palpation tasks. An interesting 4-dofs parallel soft structure, miniaturized for wearable application at the fingerpad, was presented in [18] and pneumatically actuated. The drawback of these designs is that usually pneumatic actuators require bulky units, positioned at a distance from the actuated body segment and connected to the wearable interface through tethers. To miniaturize such hydraulic actuators using conventional sealing methods (i.e rubber sealings and o-rings) would be difficult due to the significant increase of friction forces with respect to the actuation output forces. Moreover, conventional pumping mechanisms use cycled operation, that is not suitable for direct, linear modulation of the output signals.
A different technology makes use of low-boiling point liquids and thermal energy: thermo-pneumatic actuators can result in a very compact design, composed of just a sealed cavity filled with a low-boiling point liquid, and coupled with a heating element. Early investigation on this technology was performed for Braille or tactile display actuators [19], [20]; recently it has been proposed for wearable haptic devices [21]. Main limitations are in the output bandwidth, due to the need of fast energy absorption and dissipation in the liquid, especially when rendering dynamic signals. An innovative hydraulic actuator using electro-active-polymers in a stacked configuration has been proposed in [22] as a proof of concept for development as an haptic device.
Still, the quality of the signal can be affected if pressure modulation is pursued through conventional valves. In [23] a better performing actuating method was contrived to achieve accurate pressure modulation embedded in a compact desktop device. In the work it is experimented with completely soft tethered silicone haptic thimbles. With the aim of rendering high-quality signals, [24] presented a different method for driving similar soft haptic thimbles with pneumatic pouches: in the study, remote audio speakers were sealed to tethers and in turn to the device, and used to linearly modulate pressure of the air chamber.
Inspired by the above methods, we investigated whether hydraulic or pneumatic actuators could be miniaturized and embedded close to the actuated location, resulting in wearable, untethered devices with a compliant and noiseless interface to transmit signals to the skin.
C. Ferrofluid Actuators in Haptics
When reducing the size of the actuators, one concern with pneumatic sealings is to obtain smooth movements, due to the non-linear scaling of the friction and output forces. In [25], [26] sealed mechanical couplings with no static friction were achieved through the use of ferrofluids - stable colloidal dispersions of ferromagnetic nanoparticles in mineral oil. Ferrofluid was also adopted in miniature and micro pumps, as in [27] or medical actuators, as in [28]. In these architectures, a permanent magnet guaranteed to hold the position of a ferrofluidic sealing layer, while external actuators were used to drive the mechanism. In [29], a ferrofluid-based electromagnetic haptic actuator was developed, using the change of the volume in the magnetic circuit gap and the ferrofluid itself, enclosed in a membrane, as a direct mean to convey haptic sensations. In the recent [30] the ferrofluid sealing method was embedded directly within the active element of the electromagnetic actuator. Here the magneto-hydrodynamic levitation method was used for obtaining oscillatory movement of moving part, in the scope of a miniaturized pump for an artificial heart application.
In haptics, the use of ferrofluid as a shape-modulated mean through an external magnetic field (rather than as a frictionless hydraulic sealing), has been also proposed to obtain spatially distributed cues (i.e. [31], [32], [33]).
In this work we applied the principle of magneto-hydrodynamic levitation for obtaining clean and linear pressure modulation in a direct-drive, miniaturized haptic thimble. The main advantages with respect to alternative methods are in the low-noise, no backlash rendering, due to both the direct drive and soft hydraulic interface adhering to the fingerpad. With respect to similar pneumatic or hydraulic devices, the approach allows an embedded, untethered hydraulic chamber and linear, wide bandwidth rendering features.
The final prototype with the embedded hydraulic actuator is shown in Figure 1, and a scheme of the working principle is pictured in Figure 2: it obtains a compliant and soft interface with the skin with clean and noiseless output rendering. Preliminary findings and the actuator prototype are presented in [34]. We further investigate here how tiny contact transients can be rendered by the novel device into an experimental finger-teleoperation setup, and how these tactile information can improve performance of the subjects in the proposed task.
Prototype of the haptic thimble making use of the direct-drive hydraulic actuator.
Scheme of the operation principle: the ferrofluid acts both as a frictionless hydraulic sealing and as a polar expansion for the electro-magnetic linear actuator.
The paper is organized as follows. In Sec. II we present an electromagnetic model of the direct-drive hydraulic actuator, and the design of a first prototype. Experimental evaluation is presented in Sec. III: characterization of the actuator is presented in Sec. III-A. Sec. III-B is devoted to a user study meant to investigate the capabilities of the proposed approach for fine haptic rendering. Lastly, in Sec. III-C we experimentally evaluate the method in a simplified teleoperation setup, focused on haptic rendering of fine contact transients. Conclusion are presented in Sec. IV.
Model of the Direct-Drive Pneumatic Haptic Actuator
An electro-magnetic model has been developed for dimensioning the actuator and to understand the scaling factors related to the output force, pressure and displacement.
The following section describes the developed physical model of the actuator, which considers the elctro-magnetic circuit and the output pressure. It can be used for dimensioning the actuator geometry, taking advantage of the hydraulic force scaling effect.
The nomenclature associated to the following equations is disclosed in Figure 2. The model is axial-symmetric (cylindrical magnet and actuator) and also symmetric for the two magnetic poles.
In the hypothesis that the magnetic flux \begin{align*} R_{m}\Phi +R_{f}\Phi +R_{c}\Phi & = H_{c} d_{m} \tag {1}\\ \mu _{m} & = \frac {B_{r}}{H_{c}} \tag {2}\\ B_{m} & = \frac {B_{r}}{2} \tag {3}\end{align*}
NeFeBr magnets show a linear demagnetization curve. Hence the device can be designed so that the magnetic flux intensity \begin{equation*} A_{m} = A_{c} \longrightarrow r^{2}\pi = 2\pi r_{m} d_{f} \longrightarrow d_{f} = \frac {r_{m}}{2} \tag {4}\end{equation*}
Assuming that \begin{align*} R_{m}\Phi +R_{c}\Phi & = \frac {2 H_{c} d_{m}} {B_{r} A_{m}} = \frac {2 d_{m}}{\mu _{r} A_{m}} = 2 R_{m} \\ R_{c} & = R_{m} \\ \frac {h_{c}}{\mu _{0} A_{c}} & = \frac {d_{m}}{\mu _{m} A_{m}} \tag {5}\end{align*}
The coil thickness (\begin{equation*} h_{c} = \frac {\mu _{0}}{\mu _{m}} d_{m} = \frac {H_{c} \mu _{0}}{B_{r}} d_{m} \tag {6}\end{equation*}
To model the output pressure, we find the Lorentz force:\begin{equation*} F_{m} = B_{c} i_{coil} l_{coil} \longrightarrow F_{m} = B_{c} J V_{coil} \tag {7}\end{equation*}
\begin{equation*} B_{c} = \frac {\Phi }{A_{c}} = \frac {\mu _{m} H_{c}}{2} \frac {A_{m}}{A_{c}}=\frac {\mu _{0} H_{c}}{2} \tag {8}\end{equation*}
With \begin{equation*} V_{coil} = 2 \pi r_{m} h_{c} d_{f} = \pi r_{m}^{2} d_{m} \frac {\mu _{0} H_{c}}{B_{r}} \tag {9}\end{equation*}
We find then the output force \begin{align*} F_{m} & = J \frac {(\mu _{0} H_{c})^{2}}{2 B_{r}} \pi r_{m}^{2} d_{m} \\ P & = J \frac {(\mu _{0} H_{c})^{2}}{2 B_{r}} d_{m} \tag {10}\end{align*}
\begin{equation*} K_{f} = \frac {F_{m}}{i_{coil}} = \frac {F_{m} N}{J h_{c} d_{f}} = N \mu _{0} H_{c} \pi r_{m} \tag {11}\end{equation*}
\begin{equation*} K_{p} = \frac {F_{m}}{i_{coil}} = \frac {F_{m} N}{J h_{c} d_{f}} = \frac {N \mu _{0} H_{c} \pi }{r_{m}} \tag {12}\end{equation*}
The described physical model can be used for a preliminary design and parametrization of the actuator. Because of the moving magnet setup, the length
A. FEM Electromagnetic Simulation
Based on the above model, and considering final dimensions of the device and practical approximations for the magnets armature, an actuator has been designed according to the parameters listed in Table 1.
The Finite-element-method (FEM) has been used to simulate the electromagnetic characteristics. An axisymmetric model has been implemented and simulated with FEMM Magnetics software. In particular, we were interested in simulating the output pressure characteristic with and without the external iron armature, and at different displacements of the internal moving magnet.
The mesh size was automatically generated with adaptive size for the air boundary region (Conforming Delaunay Triangulation method) and with maximum
A set of simulations were run for each condition. The first aimed at estimating the current intensity to output pressure characteristic, with (a) and without (b) the iron armature. Increasing current intensity values in
1) FEA Results
The current intensity to output pressure characteristic showed a linear behavior in the simulated range due to magnetic field intensity well below the saturation point of the iron and ferrofluidic regions (maximum magnetic field intensity equal to 1.24 T in the magnet). Results are shown in Figure 3. Regarding the presence or absence of the iron armature, given the longitudinal proportions of the actuator the effect on the output force was reduced, as visible in Figure 3. Therefore, in the final prototype implementation, it has been chosen an iron-less design to further reduce the weight of the actuator.
FEM simulation: characteristic of the output pressure varying current intensity, and characteristic of the output pressure varying displacement of the moving magnet with respect to the center-line.
Regarding the second FEA condition, it evaluated how the output pressure was influenced by the displacement of the magnet. The symmetric mid position of the magnet maximizes the magnetic flux components in the coil regions perpendicular to the travel direction, hence obtaining the maximum output pressure (here simulated with 0.4 A constant current intensity). Conversely, during operation the magnet can be displaced from the mid position, reducing the output pressure. Simulation shows the output pressure drops at 90% of the maximum at
B. Prototype Implementation
The cylindrical body of the actuator was produced exploring two different methods: by SLA (stereolithography) 3D printing, and by CN manufacturing at the lathe from polyacetal (POM) plastic. The design constraint was the thickness of the coil support, which has to be the thinnest possible in order to minimize the air-gap in the magnetic circuit. Both manufacturing methods achieved good results. Also, the ferrofluid polar expansion allows for relaxing the required tolerance between the magnet and the inner diameter of the actuator body (here, 0.1 mm gap was used).
A collet was designed for the hydraulic connection between the actuator body and the soft thimble. On the other side, a mechanical end-stop at one end of the channel was added to prevent the magnet to slip away during assembly due to the absence of static friction.
To take full advantage from the hydraulic transmission solution, the whole thimble body was designed to be soft, with the actuator being the only rigid part, in order to improve the comfort and to better comply with different finger dimensions. To this purpose the shape of the thimble was designed with two flexible side flaps at the base of the finger phalanx. The hydraulic chamber was centered below the fingerpad and connected by a flexible channel to the actuator. The actuator was placed on the finger dorsum, outside the hand workspace. The thimble was designed with geometrical constraints such to allow printing in a single piece. SLA printing and flexible resin (Liqcreate Elastomer-X) were used. An overview of the parts implemented in the prototype is shown in Figure 4.
Concerning wearability of the device, the absence of actuators or rigid components in direct contact with the fingerpad contributed to improved comfort and fit of the soft thimble. The soft hydraulic chamber conformed effectively to the subjects’ fingerpads without requiring additional adjustments, as experienced during the perception and teleoperation experiments described in the following sections.
On the other side, there are limitations in the current development and manufacturing methods to solve looking at the prolonged operation and robustness of the soft interface.
The soft resin material available nowadays for SLA printing proved permeable to liquids to some extent. In the time span of weeks or months, the liquid volume in the channel decreased, causing a change of the offset of the internal magnet. The resulting effect can be evaluated by the FEM simulation in the longitudinal displacement condition: within
Additional investigation can be performed using different liquids (e.g., oils) or using coatings for the inner surfaces of the fluid channel the cavities. Other design constrains are due to the adopted 3D printing technique. Although SLA printing provides particularly good results when dealing with small features and details, the shape of the liquid channel must adhere to certain geometrical requirements in order to print the part in one piece. It has to be considered that soft resins are conversely more viscous than hard resins when uncured and during printing. In order to clear uncured resin from the thin hydraulic channel, their section could not be reduced below
Finally, a mechanism to tune the volume of the chamber is to be considered for further developments and for extend compatibility of the device with different users. Although the soft structure of the thimble can already and comfortably accomodate different finger sizes, again the internal offset of the magnet will change, depending on the deformation at rest applied by the finger to the soft interface. A tuning mechanism can also optimize the amount of linear stroke designed for the internal magnet, which in turn determines the overall size of the actautor.
C. FEM Simulation of the Fingerpad Interface
A FEM simulation has been performed to evaluate the deformation of the fingerpad interface. In the model, represented in Fig. 5(a), the finger was schematized including the bone and the cartilage, while the pouch was inflated with the nominal hydrostatic pressure equal to 75 mbar.
FEM simulation model. (a) Section view of the model, including the finger (bone and cartilage) and the fingerpad soft interface, with the pouch inflated at the nominal output pressure of the actuator. (b) Displacement contour plot showing the large deformation of the pouch and the effective contact area induced by the combined effect of inflation and frictional sticking. (c) Equivalent Von Mises strain contour plot: elastic stretch is concentrated in the contact area of the pouch.
For the fingerbone material, we assumed a linear isotropic behavior with Young’s modulus equal to 18 GPa, and a Poisson ratio equal to 0.2 which are the typical values adopted for the cancellous fingerbones [36], [37]. Instead, the soft tissue cartilage of the distal phalanx was modeled through a Neo-Hookean hyper-elastic material with constants
The overall domain was discretized with elements with a size of 1 mm and a linear order to preserve local instability effects. The contact between the pouch and the cartilage finger was simulated including a frictional behavior, admitting a frictional coefficient of 0.74 [37]. Due to the compliance of the finger cartilage and the resin pouch, a symmetric formulation was chosen for such a contact. The Augmented Lagrange method was adopted to achieve the most accurate contact results. Besides, a stabilization damping factor of 0.8 was necessary to dissipate the energy associated with the local instability of the mesh arising at the contact initiation. A fixed support constraint is imposed on the base of the finger and the pouch. Due to the high non-linearity of the problem, the solution was achieved by dividing the hydrostatic load into subsets. The true scale displacement contour is represented in the section view of Fig. 5(b). During inflation, the pouch experiences a large deformation, concentrated in the fingerpad region. In particular, sticking occurs, generating an ultimate contact area of 200 mm2. Such a contact area behaves like a kinematic hinge for the pouch which rotates around the sticking area, achieving a maximum displacement of around 2.6 mm. At the same time, a gap is generated near the edge of the finger. No relevant deformation is visible outside the fingerpad region. On the other side, due to inflation, elastic stretch is concentrated in the thin wall region of the pouch, as shown in Fig. 5(c) where the equivalent Von Mises strain is represented.
In similar simulations, while the precise interaction forces might not represent a reliable estimation of the final device operation, due to different finger shapes and dynamically variable stiffness of the fingerpad tissues, the above results provide a qualitative evaluation regarding the area of deformation, which, as intended, is located at the middle of the fingerpad. Additional information to consider in further design is provided by the global displacement of the hydraulic pouch: increasing the stiffness of the structure connecting the pouch to the upper part of the thimble can reduce such compliance, and eventually increase deformation at the fingerpad. On the other hand, it would reduce the adaptability of the device to different finger sizes.
Experimental Evaluation
Experimental characterization of the actuator was performed at the bench measuring the output characteristic, the step response and the dynamic bandwidth, both of the actuator only, and of the final prototype integrating the actuator in the soft thimble interface. Then, performance of the haptic thimble was evaluated in a perception experiment and through a simplified teleoperation scenario, exploring rendering of fine contact transients.
A. Characterization of the Actuator
For the experimental characterization of the actuator, the hydraulic channel was connected through a silicone tube (4 mm internal diameter, 8 cm length) to an analog pressure sensor (MPXH6115AC6U) for measuring the output bandwidth, and to a digital pressure sensor (Bosch BMP280) for measuring the output pressure characteristic. A Teensy 3.6 microcontroller board and the Texas Instruments DRV8838 motor driver were used for acquiring the sensor data and for driving the actuator. The driver was powered by a 3.7V, 1200 mAh Li-Po battery. The current over pressure characteristic was estimated by driving the actuator with slow voltage ramps, both ascending and descending. The frequency response characterization was performed with a series of sinusoidal signals at different frequencies. The amplitude of the sinusoidal stimuli was equal to half the supply voltage. A second experimental characterization was performed to evaluate forces at the fingerpad applied by the final fingertip device implementation (hence including the soft body, the liquid channel and the soft interface with the fingerpad). In the second experimental characterization including also the soft thimble, a miniature force sensor (OptoForce 10N, 2 mN resolution) was used, and mounted through a 3D printed support in the same position of the fingerpad (Figure 7).
Characterization of the actuator at the bench: current intensity-to-output pressure characteristic (zoom in the Figure on the right highlights the substantial absence of static friction), frequency and step response.
Characterization of the fingerpad interface using a miniaturized force sensor (a) in place of the finger (b). Step response with input amplitude equal to nominal current intensity of the actuator (0.4 A): comparison between sharp reference step response, and smoothed reference step responses as used in the perception experiment in Section III-B. (c) Frequency response.
1) Characterization Results
The expected magneto-hydrodynamic effect of the ferrofluid polar expansions is highlighted by results of the characterization: Figure 6 (top) shows a linear characteristic, both in the loading and unloading direction, with no substantial static friction. The characteristic has been enlarged in the close-to-zero range to highlight how current values as low as 0.5% of the nominal range (corresponding to 3 mA) resulted in a measurable output pressure. Regarding the pressure constant of the actuator, the value of
Regarding the step response, results show a very repeatable behavior of the actuator. The signals, shown in Figure 6, are averaged over ten repetitions and reported with standard deviation lines (light dotted lines).
The measured output bandwidth of the actuator reaches the 200 Hz cut-off frequency. Such frequency response is particularly good when compared to the most of miniature actuators not specifically designed for wide-bandwidth haptic rendering. Conversely, voice coil and piezo actuators may surpass this value, although they face other constraints such as low-frequency rendering limit for piezo actuators, and relatively higher mass and encumbrance for voice coil devices.
Results of the second characterization session, using the force sensor at fingerpad (Figure 7) show the step response of the device including the liquid channel and the soft membrane in contact with the fingerpad (here, in contact with the force sensor). With respect to Figure 6, here the measured system includes the soft pouch and the contact distribution between the pouch and the hemispherical force sensor. According to the previous characterization, the reference step amplitude is set at the nominal current intensity of the actuator (0.4 A). The measured force amplitude of the step is
The rise time, equal to
B. Perception Experiment
For the perception experiment, the final thimble prototype shown in Figure 1 was used. It aimed at measuring minimum perception thresholds in discrimination of different contact transients. In the perception experiment and in the following teleoperation experiment, ten healthy subjects (aged from 25 to 40 years old, 7 male) were enrolled. The experimental procedures were approved by the Ethical Review Board of Scuola Superiore Sant’Anna (approval number 152021).
1) Perception Experiment Setup
Two psychophysical perception experiments based on a forced-choice paradigm were performed. In both experiments, for each repetition a sequence of two stimuli was presented to the subject. The subject had to answer whether the perceived stimuli were equal or different. The stimuli were randomly chosen to be the same or different. A 3-down 1-up convergence method was used: for each wrong answer, the intensity of the stimuli (or difference from the sham stimuli) was increased (up step). Conversely the intensity of the stimuli was halved (down step) after a sequence of three correct answers. The first experiment used as stimuli two different raising edges, a pure step signal (sham stimulus) and a smoothed raising edge with sinusoidal shape (Figure 8 left). The intensity of the stimulus was set as the time length of the smoothed signal with respect to the sharp rising edge. By diminishing the length of the smoothed raising edge, the signal approaches the pure step sham stimulus. In the second experiment a similar smoothed rising edge stimuli was used and compared to a pure step sham stimuli. Here the intensity of the stimuli was modulated by the amplitude of both the signals, as shown in Figure 8 (left).
Psychophysical experiment: presented stimuli (left), convergence results (mid) and averaged perception thresholds (right).
2) Perception Experiment Results and Discussion
The first experimental condition investigated to what extent subjects were capable of discerning different rising edge shapes rendered by the proposed device in a simulated contact transient. Results show the sharp rising edge was distinguishable from the smoothed rising edge up to 54 ms length (Figure 8, right). Considering that the sense of touch spans to wider bandwidth limits [39], the result is meaningful of the device limits in rendering dynamic signals. The difference between the ideal step response and the generated sharp and smoothed step responses is clarified in Figure 7 (c). Due to the elastic and damping properties of the soft interface, a transient with an overshoot and a decay is visible. Also, the sharp step reference (marked as 1 ms) shows a rising time of ~10 ms, attenuating the higher frequency components of the ideal response.
The second experimental condition investigated how the different contact transients were still distinguishable when diminishing the intensity of the transient. This is relevant also concerning haptic device design and implementation: miniature mechanism suffering non-linearities such as static friction or backlash may struggle to accurately render low-intensity signals, as seen, for instance, with miniature rotary motors with no ball bearings or in gear reducers. With the proposed device, the two reference signals could be distinguished up to 11 mbar intensity (mean value). To this regard, it has to be considered however that the hydraulic soft interface still introduces filtering in the rendered signal, as shown for the step response in the characterization of Figure 7. Convergence results are shown in Figure 8 (middle).
C. Finger Teleoperation Experiment
The experiment aimed at exploring capabilities of the device in rendering fine contact thresholds in a real teleoperation setup, although simplified to a single dof.
1) Teleoperation Experiment Setup
The teleoperation setup implemented a pressure-based sensorized finger, in order to match one to one the measured pressure with the rendered haptic signal. The sensor was built using a soft silicone dome with 8 mm axial radius and 24 mm length (Figure 9) and a pressure sensor (BOSCH BMP280). This method allows for a wide sensitive area, corresponding to the whole silicone dome surface. Sensitiveness can be adapted using different pressure sensors; here, for the implemented device the sensitivity was
The sensitive fingerpad sensor developed for the robotic finger: a pressure sensor is embedded in a pressure chamber underneath a soft silicone dome.
At the leader side, the user was equipped with a custom made data-glove, implementing a bending sensor (73 mm length resistive bending sensor by SpectraSymbol) to measure the bending of the first phalanx. Sensor output was linearized between the open and closed (90° angle of the first phalanx) finger position. Overview of the teleoperation setup is shown in Figure 10.
Setup of the simplified (single dof) teleoperation experiment, investigating perception of contact thresholds with a 1:1 match of the measured and rendered pressure.
Teleoperation loop was operated at 100 Hz, limited by the maximum sampling rate of the pressure sensor. Although higher rates are usually required for stability in force-feedback teleoperation, here the setup consisted of a tactile-feedback teleoperation, hence not subjected to stability issues. Subjects were asked to wear the data-glove and the haptic thimble, and seated in front of a desk in front of the teleoperated robotic finger. The experiment was performed in three conditions: with visual and haptic feedback (HV) with haptic feedback only (H) by covering the robotic finger with a panel, and with visual feedback only (V) by turning off the haptic rendering. In each condition, subjects were asked to repeatedly close the index finger up to reach the contact with a fixed finger opposed to the actuated robotic finger, then to stop and go back to the open hand position as soon as they perceived the contact (by vision or touch). In order to minimize motor memory, distance between the starting position and contact was randomly changed after each trial.
2) Teleoperation Experiment Results and Discussion
Regarding the teleoperation experiment, the haptic only (no vision) condition is rarely performed in literature. Here it was possible due to the simplified single dof setup and to the absence of more complex motor coordination. Noticeably, results of the H condition (Figure 11) significantly improved over the V for the exerted pressure and for the reference position indent, evidencing the consistency of the provided feedback. The HV condition performed very close to the H condition only for the pressure and indentation indices. Averaged values for the Contact Pressure are H: 26.7, HV: 28.7, V: 37.1 mbar with statistical significant differences between H and V (
(left) Contact transients averaged over ten repetitions of a sample subject for the three experimental conditions. (right) Aggregated results of all subjects. The * and ** symbols represent a statistical significant difference with
Interestingly, the HV did not perform the best in all the metrics, as it might be expected by the integration of the two different sensory modalities. The overall result for the HV can be explained considering the different task execution strategies adopted by subjects, and to the presence of two complementary metrics (contact intensity and speed). In the HV, the adopted strategy was probably to rapidly approach the target as in the V, and then to reduce the speed in proximity of the estimated contact position, in order to perceive the exact contact threshold by tactile feedback. Hence, the average contact velocity and execution time for the HV appears in between the V and H condition. Regarding the contact pressure and indentation metric, the averaged results appear very close between the H and HV with no significant difference, while both significantly different from the V. It suggests subjects were effectively using the provided tactile information also in the HV, with no additional benefits carried by vision in the precise perception of the contact threshold.
In Figure 11 (left) we show for a sample subject the behavior in the time domain of the contact condition. In agreement with the aggregated results, it can be noticed how the subject approached the contact threshold at different velocities depending on the sensory condition. Maximum values of the contact pressure shows how tiny transients could be precisely perceived also with haptic feedback alone, without visual guidance.
Conclusion
In this work, we investigated how low-noise, tiny tactile stimuli can be rendered by wearable haptic devices. To this purpose, a novel miniaturized hydraulic actuator was developed, showing a highly linear output due to the substantial absence of static friction. The effect was obtained using ferrofluid as hydraulic sealings and at the same time as polar expansions of a linear electromagnetic actuator. The method results in a direct drive, miniature hydraulic actuator, suitable for implementation in wearable haptics applications. With respect to other pneumatic solutions, the advantage is of being a miniature, self-enclosed actuator rather than tethered with remote pumps. With respect to other linear and wide bandwidth solutions such as piezo and voice-coils, the advantage is in the rendering capability extended to low dynamics and static signal for the first, and in lower encumbrance and soft interface for the latter. The use of flexible SLA resins allowed for a single-piece construction of the soft thimble, integrating the hydraulic chamber and a soft and compliant interface with the fingerpad. The whole soft thimble has been simulated with FEM, validating the main actuated area is located at the middle of the fingerpad.
The analytical model presented in this work is proposed for a first dimensioning step of a novel actuator design, while the conducted magnetic FEM analysis showed a closer matching with the final prototype characterization, due to modeling of non-ideal effects of the magnetic circuit. Characterization and perception results highlighted the interesting capability in clean rendering of tiny transients, although the response deviated from the ideal one for the fastest dynamic stimuli, due to the compliance of the soft interface. This feature is difficult to achieve with conventional miniature actuators and is relevant for conveying contact information during fine manipulation tasks. The intensity and frequency content of discrete transients becomes informative of contact threshold with different velocities or with hard and soft materials [40], and of slip condition. Additional studies can be performed regarding the shape and stiffness of the soft fingerpad interface: here, a first characterization with a miniature force sensor in place of the finger was performed, evidencing a resonant peak and a more limited frequency bandwidth. However, such evaluation is challenging to perform especially in terms of intensity of the perceived signal, due to the difference between the real fingerpad, presenting a wider contact area and distribution of mechanoreceptors, and the force sensor, performing a lumped measurement of the signal intensity.
The conducted teleoperation experiment, although in a simplified single dof setup, evidenced interesting performance in fine modulation of a contact threshold with a 1:1 matching between the measured and rendered pressure. Remarkably, the maximum exerted pressure metric performed better in the haptic only condition (without vision).
While rendering performance were overall satisfactory and particularly good in terms of linearity and low noise of low amplitude signals, on the other side other design and usability aspects have to be addressed to reach full usability of the device in the long term. In particular, existing 3D printed soft resins appear permeable to liquids in the long term (weeks or months), changing the amount of liquid in the channel and therefore the offset of the magnet in the actuator. Further developments can involve both different materials (resin, liquid, or internal coating) to solve this issue, as well as a tuning mechanism for the volume of the actuated chamber. The latter in particular would allow also for a broader compatibility of the device for different finger sizes. Even if the structure of the thimble is soft, different finger sizes result in different offset position of the internal magnet at rest. Beyond the conceived full-device design implemented in this work, the core direct-drive hydraulic actuator can be potentially implemented to other hydraulic/pneumatic design, yet with remote tethered actuation, already proposed in literature, such as the 4 dofs soft device presented in [18]. More complex and ergonomic distribution of the soft interface at different locations of the hand can also be envisaged, exploiting the potential of the 3D printed soft structures.
NOTE
Open Access provided by 'Scuola Superiore "S.Anna" di Studi Universitari e di Perfezionamento' within the CRUI CARE Agreement