Introduction
Personal Protective Equipment (PPE) safeguards individuals from potential workplace hazards and risks [1]. PPE is defined as any device or accessory that is meant to be worn by employees to protect them from one or more threats that could endanger workplace safety. PPE is a broad category that includes a variety of tools and outfits made to lessen the effects of a variety of risks, such as ergonomic, physical, chemical, and biological dangers. These specialized instruments are essential for establishing a safe working environment, ranging from gloves to helmets and high-visibility vests [2]. Industries identify elevated and reduced risk areas, necessitating workers in these zones to utilize different PPEs adapted to the specific level of necessary protection. Nowadays, ensuring operators use correct PPE remains challenging as inspections primarily rely on human intervention. In [3], four reasons why PPEs are still not correctly used were highlighted. Specifically, the reasons are divided into underestimation of danger, absence of PPE in the work environment, the negative influence of coworkers, and physical discomfort. One of the main issues in the industry safety application is the lack of a system within a workplace that verifies whether the worker is correctly wearing PPE. One solution adopted is to integrate Radio-Frequency Identification (RFID) into PPEs so that the entry and exit of PPE from the work area can be tracked. The works reported in [4], [5], and [6] propose solutions that allow tracking and locating devices using the received signal strength indicator for indoor applications. However, these solutions cannot ensure the operator wears PPE during work activities. Further, RFIDs are increasingly used as sensors even though their applicability in the real world and an industrial scenario is still in question [7]. Research focused on safety and smart PPE is rapidly growing. Indeed, different solutions apply the industrial internet of things concept to wearable sensor systems for industry scenarios [8], [9]. The work described in [10] introduces a prototype of a smart helmet designed to monitor workers’ environmental conditions and conduct a near real-time risk assessment using WiFi to exchange data with the centralized server. In work [11], a smart wearable system is developed to monitor cases of epileptic patients working in an industrial environment using WiFi as the transmission method. The work described in [12] proposes a custom, low-power sensors node using various sensors to monitor environmental conditions, particularly air quality. It continuously monitors environmental data in real time and transmits it to a cloud server using LoRa. The work presented in [13] discusses deploying a wearable wireless sensor network to monitor hazardous gases in an industrial environment using an RF transceiver (Xbee) for communication data. Also, the work in [14] uses the same communication method for a sensor node for environmental monitoring.
The main challenge of wearable sensor node systems is the design of an effective, efficient, and safe power supply (eventually including energy storage components) and management systems. Although many proposed solutions require batteries [10], [11], [13], the latter can pose potential hazards in case of malfunction or failure. Battery disposal can be costly and significantly impact the overall life cycle of PPE. To ensure better safety and usability over time, solutions [12], [14] have opted for secondary power supply systems (solar panels), requiring low-power consumption systems with increasingly efficient energy harvesting systems. However, solar panels are difficult to integrate into industrial wearable systems, as they require a continuous light source for proper operation and must be exposed, making them fragile and easily damaged. Additionally, solutions [10], [11], [13], [14] all use active communication systems that require tens of milliamps during transmission, necessitating a large storage capacity (order of Farad), which is also challenging to integrate into a wearable system.
The focus of the paper is on the architectural and system-level design, the realization of a first battery-free proof-of-concept prototype of smart PPE, and its functional validation in a realistic scenario. The novelties introduced by the prototype are as follows:
Ultra-low-power battery-free wearable device.
Capacitive sensing to actively monitor the correct use of PPE by the worker in real-time.
Easy integrated into the industrial infrastructure.
New prototype of wearable smart PPE with intelligent sensor technology, fully wirelessly powered to monitor the correct wearing of PPE to reduce hazards. The smart PPE comprises an ultra-low-power microcontroller unit for capacitive sensing, a UHF power harvester, and an RFID tag for data communication with the UHF RFID reader.
The paper is structured as follows: Section II provides an overview of different technologies for realizing smart PPEs, emphasizing the choices to design the smart PPE prototype. Section III is focused on the architectural and system-level design, including hardware design choices and the related firmware/software development, for the transmitter and smart PPE. Section IV describes the experimental and validation tests of the proof-of-concept prototype, focusing mainly on fundamental aspects of the system, ensuring low consumption, energy harvester efficiency, sensor functionality, and testing the complete prototype in a realistic scenario. Section V reports the quantitative results obtained from the experimental tests. Section VI discusses the results, highlighting the prototype’s performance with respect to the state-of-the-art. Finally, in section VII, conclusions are drawn, emphasizing the advantages and potential applications of the proposed system.
Technology Overview
Nowadays, there is a strong trend towards designing and implementing devices in the Internet of Things (IoT) field, characterized by compact size, wireless connections, extended autonomy, and low management cost [15]. However, these IoT systems are typically battery-powered. Consequently, all the communication systems involved are oriented towards minimizing power consumption, assuming a power source completely independent of the communication system itself. This category includes systems based on Bluetooth Low-Energy, Zigbee, Ant, and Thread.
Alongside these communication systems, the need to wirelessly transmit energy to power or recharge a battery has emerged. However, typically, these approaches either involve short distances (systems based on inductive or resonant magnetic coupling), mainly used for charging battery-powered devices [16], [17], or utilize a non-electromagnetic wireless transmission approach, such as ultrasonic systems [18]. Although non-electromagnetic wireless systems are potentially interesting, their actual level of technological maturity and the feasibility of integrating them into other applications still need to be clarified. These technologies often rely on proprietary setups that require the installation of custom devices throughout the working environment. Their performance might be influenced by environmental factors that are not always easy to control (e.g., lighting conditions in outdoor environments) or specific workspace characteristics (presence of acoustic insulation in noisy environments or the need to remain within the line of sight of the lighting source).
On the other side, looking at commercial, proven and widespread solutions, there is also an electromagnetic wireless system for long-distance energy transmission, sometimes operating on the same frequencies as the communication channel. Indeed, RFID, designed to detect and identify objects with radio-frequency devices (transponders or tags) using specific tools or readers, combines bidirectional data and energy transmission in a single solution. Tags use the principle of backscattering to communicate with the reader and consist of varying (and thus encoding data transmission) the electrical/electromagnetic characteristics of the tag in response to interrogation by a reader. Simultaneously, the reader is responsible for powering and modulating (transmitting) data in the same electromagnetic propagation and reading the tag’s response regarding variations in electrical/electromagnetic characteristics. The possible electromagnetic couplings between antennas are inductive and radiative, leading to different models and equations and resulting in different operating distances: near-field and far-field, both exploited in different RFID solutions. The choice between the two regimes also depends on the geometric dimensions of the antennas (which can determine the size of the devices) and the frequencies in use. Regarding RFID technology, there are four possibilities [19]: Low Frequency (LF): 125 kHz to 134 kHz; proximity readings for passive tags at the order of a few centimeters. High Frequency (HF): 13.56 MHz; proximity readings for passive tags at the order of (a few) tens of centimeters. UHF: 865 MHz - 928 MHz; long-distance readings. Microwave: 2.4 GHz; long-distance readings. Considering the most suitable technology for the system based on the above information, we can exclude the RFID LF technology as it is not suitable for the desired distances. A similar reasoning applies to RFID HF, which, despite potentially reaching distances of interest, is mainly used for short-range communication, for instance, in smart cards or devices based on near-field communication, where we generally talk about contactless communication rather than wireless. The RFID UHF technology is already widely used in logistics and asset tracking, where a longer range, low production and installation costs, and zero maintenance (thus high adaptability to different operational contexts, including environmental and mechanical constraints) are required. From a distance perspective, it is compatible with the analyzed system. Microwave RFID technology, similar to UHF RFID, can reach long distances using semi-passive or active devices. It should also be considered that the band around 2.4 GHz is already extensively used by other communication systems (Bluetooth, WiFi) and could be a source of interference. In contrast, the band around 900 MHz (UHF RFID) is more free. UHF RFID-based systems allow not only remote power supply at long distances but also localization in an indoor environment of RFID tags [20]. RFID tags utilize the backscattering principle to enable communication with the transmitter without using an active communication method like RF transceivers, thus reducing power consumption. In addition, RFID tags are already widely used in industry [21], making integration of the prototype within the industry infrastructure easier and faster. Therefore, the UHF RFID technology is the best solution for using the same RF source to transmit data and transfer power at the same time. Another interesting use of common RFID tags is that they can be used both for data communication and also as sensors [7]. The antenna itself has a dual function: communication and sensing. The operating principle involves a change in the electrical properties of the sensor antenna (e.g., related to surrounding environmental conditions), corresponding to a change in impedance, which causes a change in the backscatter signal, allowing the reader to decode the information. Several solutions have been presented in the literature for RFID sensors to measure environmental parameters [22], [23] or for structural health monitoring, such as to monitor stress and cracks in materials [24], [25] or corrosive processes [26]. Although these applications are potentially very power-efficient and attractive for the smart PPE application, as only the RFID antenna is used, having an antenna that presents the right trade-off between sensing and communication is still challenging. Communication and sensing capabilities demand opposite requirements. The tag’s antenna must be matched with the chip, while sensing requires a continuous variation of the antenna impedance [7].
The design of the smart PPE was mainly focused on the chosen energy source, considering that the power received (\begin{equation*} P_{Rx}(dB) = P_{Tx} + G_{Tx} + G_{Rx} + 20\log _{10}\left ({{\frac {\lambda }{4\pi r}}}\right )^{2} \tag {1}\end{equation*}
The last part of smart PPE design concerns the system’s ability to recognize whether the PPE is worn correctly. Again, choosing the method that allows the lowest consumption is crucial. Different sensors can be utilized to recognize proper PPE usage, primarily falling into two broad categories: optical and mechanical. Optical sensors are extensively applied in the biomedical field, measuring changes in light dispersion and absorption within the body. The main drawback of these sensors is their high energy consumption, posing a significant challenge for fully wireless systems. On the other hand, mechanical sensors, such as piezoresistive, piezoelectric, and capacitive, are also utilized. Different studies [30], [31] have shown that piezoelectric and piezoresistive sensors are highly dependent on environmental conditions, particularly temperature, thus making them unsuitable for industrial applications. Capacitive sensors are widely used to offer an easily realizable solution with a ULP MCU, good sensitivity, and an adaptive sensing configuration [32].
The next section analyzes and describes the architectural and system design to maximize the efficiency of the proposed smart PPE.
Materials
A. Hardware Design
Fig. 2a shows the assembled prototype of the smart PPE, while Fig. 2b represents the hardware configuration in its macro-blocks. The system is divided into two main blocks: the master (transmitter) and the slave (smart PPE). The M6e reader from Thing Magic was chosen for the transmitter, characterized by a maximum deliverable power of 31.5 dBm and capable of handling up to 4 antennas. Two antennas were selected for testing. The first one is the MT-242025 (Mti wireless Edge) with circular polarization and a gain of 7 dBic. The second one is the PA9-12 (Laird) with linear polarization and a gain of 12 dBi.
a) Proof-of concept of smart PPE. (I) Power harvester AEM30940. (II) ULP MCU MSP430G2553. (III) RFID tag EM4325. (IV) Aluminum electrode foil. (V) SRFC011 UHF antenna. b) Hardware representation of the main macro-blocks for developing smart PPE. c) Overview of the firmware implemented for asynchronous data exchange between the smart PPE and the transmitter (reader).
The smart PPE consists of three main components: the e-peas AEM30940 power harvester, the EM Microelectronic EM4325 tag, and the Texas Instruments MSP430G2553 MCU. COTS components such as AMS SL900A [33] (now discontinued) and Farsens ROCKY100 [34] integrate communication and harvesting functions into a single chip. On the other hand, separating the data communication and the energy harvesting subsystems could allow to specifically optimize and improve the performance of the most critical aspect. To the best of the authors’ knowledge, the power harvester e-peas AEM30940 [35] is the one with the lowest cold start equal to 3 µW and here integrated. Exactly for this reason, it was here preferred to the Farsens ROCKY100, which is characterized by a higher input power equal to 177 µW [34]. The configuration of the power harvester is shown in Table 1. A storage capacitor equal to 150 µF was used. The power harvester was configured to ensure capacitor loading to a maximum voltage of 2.7 V and enable LDO at 1.8 V with a maximum deliverable current equal to 80 mA. The maximum power point tracking was set to 50 %.
The low-power MSP430G2553 MCU was selected for three main reasons: sleep mode consumption is 0.5 µA, it implements an integrated low-power 12 kHz oscillator, and it has an integrated function called “Pin Oscillator” useful for capacitive measurement using only one external electrode [36]. The aluminum foil electrode (
B. Firmware
The Fig. 2c shows the simplified firmware for the transmitter and smart PPE for data exchange and wireless power transmission. A graphical user interface was developed in Visual Studio (1.17.1) for reader configuration and data collection. Mercury application programming interface 1.35.1.103, compatible with firmware 1.25.00.38, provided by Jadak, was used. The reader plays a key role in the proper operation of smart PPE in that it has to ensure a continuous and reliable power supply (for continuous smart PPE sensing) and a proper reading of the monitoring results (stored in the tag’s user memory). Using the graphical user interface, it is possible to ensure continuous reading by the reader, thus maximizing the transmitted power and, at the same time, displaying the collected data in real time. The reader is configured using the EPCglobal Class-1 Generation-2 communication protocol. The reading protocol is set to ensure maximum read distance [38] (TARI: 6.25 µs, Encoding: M8, Backscatter Link Frequency (BLF): 250 kHz, Session: S1, Transmitted power: 30 dBm). When the session is set to S1, the tag transitions from state A to state B when read. When the tag is in state B, it cannot be read. The EPCglobal Class-1 Generation-2 standard defines a time span (TS1) in which the tag can remain in state B ranging from 500 ms to 5 s. Each manufacturer decides how long this period should last. For EM4325 tag, the TS1 is
The firmware implemented for the smart PPE manages the capacitive measurement and the writing of the result in the user memory of the tag. As shown in Fig. 3, a time measurement interval is defined in which oscillations (counts) proportional to the change in capacitance of the touchpad (electrode) are counted. At first, the MCU performs a calibration step by repeating the no-load measurement five times, thus defining a baseline due to parasitic capacitances only. Then, the measurement is performed and compared with the baseline by defining delta counts (the difference between measurements and the baseline). An increase in capacitance due to skin contact reduces oscillations (counts) and increases delta counts. If delta counts exceed the set threshold, PPE is worn correctly. Being a threshold on a difference, where one term is the baseline, a fixed threshold can be selected. The capacitive measurement result is written to the tag’s user memory using the SPI communication protocol. A 5 s wait time between measurements is set to reduce smart PPE consumption and power supply without sacrificing the overall effectiveness, in terms of safety/security, of the proposed solution. The MCU enters a power-saving state during this period, and the storage capacitor can be recharged.
Methods
This section describes the test benches used to test the smart PPE. The preliminary tests focus on studying the power harvester, which is crucial in ensuring proper power supply. In parallel, the test bench was prepared to study the power consumption related to the capacitive measurement performed by the MCU to quantify the peak power consumption during the firmware executions and verify whether the capacitive sensing can detect whether the operator is wearing the PPE or not. Finally, a test bench was prepared that simulated realistic conditions to verify the system’s correct power supply at different distances and the correct data communication.
A. Test Bench for Power Harvester Efficiency
The power harvester plays a key role in the proper operation of the device as it manages the power supply to the smart PPE. We tested the AEM30940 power harvester to quantify the efficiency from the input (matching network and rectifier) to the storage capacitor (150 µF). Efficiency was calculated as the ratio of the power required to charge the storage capacitor to the input power (2).\begin{equation*} \eta = \frac {\frac {0.5\cdot C\cdot V^{2}}{\Delta t}}{Pin} \tag {2}\end{equation*}
Next, the power harvester was tested in more realistic conditions to evaluate the transmitter antenna types and different receiver antenna orientations. The M6e reader was used first with the linear polarization antenna (PA9-12) and then the circular one (MT242025). The helical antenna (ANT-916-CW-RAH) was used for the receiver and was oriented along the three directions (X, Y, and Z). The power harvester was placed at progressively greater distances starting from 2 m to 5 m with a step size of 1 m. Each test was repeated six times.
B. Test Bench for MCU Firmware Consumption and Capacitive Measurement
The algorithm to detect whether the operator is wearing PPE correctly was performed using an aluminum foil electrode (
The MCU MSP430G2553 was tested to evaluate its power consumption during capacitive measurement. The Texas Instrument INA240A4, a precision current sensing amplifier with a gain of 200 V/V and a zero current mid-dynamic voltage, was used for the test. The sensing resistance chosen was
C. Test Bench for Smart PPE in the Realistic Scenario
The proof-of-concept of smart PPE was tested in a realistic scenario to evaluate the feasibility of wireless power supply and data communication with the reader. Fig. 4 shows the test bench; all components are connected as shown in Fig. 2a. The test involves the use of the M6e reader with the Tx antenna MT-242025 and the smart PPE consisting of MSP430G2553 MCU, tag EM4325, and power harvester AEM30940. Two flexible antennas, Armata SRFC011 and Montana SRF21019, were used for the power harvester, characterized by a gain of 2.46 dBi and 1.9 dBi, respectively. The reader was configured to have an output power of 30 dBm. Each test was repeated six times, and the total duration for each measurement was 2 m. During this time, the following parameters were tracked: the number of responses obtained by the tag (EPC and User memory) and the number of measurements completed by the MCU. The MCU performs a measurement every 5 s if properly powered; hence, the maximum number of measurements in two minutes is 24. The tag, set in session S1, is available for reading every 1.5 s, resulting in a maximum of 80 readings in two minutes, in the case of correct power supply and reading.
Test bench set-up for validation of wireless power and data communication of the smart PPE in a realistic scenario. Four different distances from 1 m to 4 m have been tested, each spaced 1 m.
Results
A. Power Harvester Efficiency
The power harvester efficiency and wake-up time results are reported in Fig. 5 and 6, respectively. The efficiency results (Fig. 5) show that for powers less than -2 dBm, the “LOW” matching network exhibits higher efficiency than the “HIGH” matching network, which performs better for higher input powers. The efficiency remains above 30 % up to input powers of -10 dBm for the “LOW” matching network while for the “HIGH” matching network at least -5 dBm is required to have the same efficiency. For the “LOW” matching network, the minimum measured efficiency is 10 % for a power of -15.5 dBm while the maximum efficiency is 49 % at 1 dBm. For the “HIGH” network, the minimum measured efficiency is 6.5 % at -11 dBm and a maximum of 50 % at 1 dBm.
Comparison of power harvester AEM30940 efficiency versus input power using two different input impedance matching networks, one for low power (“LOW”) and the other for high power (“HIGH”).
Comparison of power harvester AEM30940 wake-up time versus input power using two different input impedance matching networks one for low power (“LOW”) and the other for high power (“HIGH”).
The wake-up time results (Fig. 6) shows the time required to charge the storage capacitor to the set voltage. As reported in the efficiency results, the “LOW” matching network provides faster charging than the “HIGH” matching network. In particular, for a power of -10 dBm the wake-up time is about 10 s and 30 s (“LOW” and “HIGH”). For lower input powers, the charging time increases exponentially. For the “LOW” matching network, a time of more than 2 m was measured for powers below -15 dBm. For the “HIGH” one, charging could not be completed for powers below -11 dBm. For input powers greater than -3 dBm, both matching networks’ measured wake-up time is a few seconds.
Fig. 7 shows the results for wake-up times using a helical antenna (ANT-916-CW-RAH) connected to the input of the power harvester and using two different antennas for the reader (PA9-1 and MT-242025). The results obtained using the linearly polarized antenna (PA9-1) show promising results only when the two antennas are oriented along the direction of maximum gain (Z), obtaining wake-up times of less than 10 s for distances between 2 m and 4 m. While with the Rx antenna oriented along the Y and X axis, the best measured times are 20 s (2 m) and 75 s (2 m) respectively. The results obtained with the circularly polarized antenna (MT-24025) show the best results with the antenna oriented along the X axis with wake-up times ranging from 6 s (2 m) to 15 s (5 m). With the antenna oriented along the Y axis, the measured times range from 11 s (2 m) to 30 s (5 m). While with the antenna oriented along the Z axis, the longer time of 45 s (2 m) was measured.
Power harvester AEM30940 wake-up time using a helical RX antenna (ANT-916-CW-RAH) and two different TX antennas (MT-242025 circular polarization and PA9-1 linear polarization). The RX antenna was oriented along the X, Y, and Z axes.
B. Capacitive Measurement and Current Consumption
The delta counts related to the capacitive measurements are shown in Fig. 8. As evidenced by the results, there is a clear difference between the two conditions tested (worn and unworn PPE). When the worker wears different PPEs, the delta counts are between 16000 and 18000. When the operator is not wearing the PPE, the delta counts are between 4000 and 6000. The power consumption associated with the capacitive measurement is significant in ensuring effective power provisioning for smart PPE. Fig. 9 shows the current consumption of the capacitive measurement. Different phases are evident during the measurement. In the initial phase, the MCU is in sleep mode. Triggered by a temporal interrupt, the MCU transitions to an active state, enabling the requisite registers for capacitive measurement. During this phase, the current consumption is approximately 60 µA. Upon initiating the capacitive measurement, a transient peak current below 100 µA is measured. Transitioning to the subsequent phase, wherein the oscillation counting transpires, the MCU adopts an energy-efficient mode with a reduced consumption of approximately 40 µA. Following the completion of the capacitive measurement, a secondary peak current, also below 100 µA, is shown. The two peaks of 100 µA are due to overlapping consumption due to firmware execution and measurement consumption. In the final phase of the process, the current consumption is ascribed to the data transmission through SPI. Inter-byte transmission intervals allow the MCU to enter a power-saving state, thereby minimizing energy consumption. Upon the conclusion of data transmission, the MCU reverts to the initial sleep mode. The duration of the capacitive measurement with data transmission lasts 14 ms.
Performance of the MSP430G2553 MCU algorithm for recognizing the correct use of PPE. Six different PPE gloves were used for the test.
C. Smart PPE Results in Realistic Scenario
Fig. 10 shows the mean and standard deviation of the measurements obtained in the realistic scenario test for two different flexible antennas (Armata SRFC011 and Montana SRF2I019). Specifically, the mean and standard deviation of the number of responses obtained by the tag and the number of measurements done by the MCU. The horizontal lines indicate the maximum number of tag responses and MCU measurements obtainable in 2 minutes of testing (80 and 24, respectively). The tests were repeated six times for each distance. The results of the Armata SRFC011 antenna are presented in Fig. 10a, wherein it is observed that up to a distance of 2 m, the reader identified the tag on to the PPE, attaining nearly the maximum conceivable reading count. This trend is mirrored in the count of measurements executed by the MCU, which underscores that the wireless power supply ensures the necessary energy for proper operation. Conversely, at greater distances of 3 m and 4 m, the system’s performance exhibits increased variability, however, guaranteeing the power supply of the smart PPE. The reader performed an average of 21 measurements, while the MCU completed an average of 13 at 3 m. While at 4 m, the reader completed an average of 26 readings, and the MCU completed an average of 15. The outcomes associated with the Montana SRF2I019 antenna are presented in Fig. 10b. Similar to the prior case, the most favorable results are achieved at closer distances, specifically at 1 m and 2 m. The reader’s recorded readings stand at 44 and 45 at 1 m and 2 m, respectively, while the MCU conducted 23 and 24 measurements correspondingly. At 3 m and 4 m, the performance of the system with the Montana SRF2I019 is degraded; however, the system is correctly powered during the tests. The MCU performed 8 and 19 measurements, and the reader recorded values of 11 and 20 at 3 m and 4 m, respectively. The results obtained using the smart PPE in the realistic scenario showed that the system is sufficiently robust even with two different flexible antennas, showing the system’s proper operation regarding alimentation and data exchange. Among the two antennas tested, the Armata SRFC011 antenna showed better behavior with less variability, thus showing more robustness for the application and industry environment.
Experimental results of smart PPE in a realistic scenario. The mean and standard deviation of the number of responses obtained from the tag (blue), the number of measurements made by the MCU (red). The test was run for 2 m and repeated six times for each distance. In two minutes, the maximum number of readings is 80 (blue dashed line), while the maximum number of MCU measurements is 24 (red dashed line). a) Results were obtained using the Armata SRFC011 flexible antenna. b) Results were obtained using the Montana SRF2I019 flexible antenna.
Discussion
The experimental tests have highlighted the main characteristics of the proposed smart PPE, focusing on architectural and system-level design to maximize power harvester efficiency, minimize consumption, and ensure proper prototype operation in a realistic scenario at different distances from the transmitter. The tests on the power harvester have shown the requirements for the correct functioning of the prototype, emphasizing the importance of selecting the matching network and antennas to maximize power harvester efficiency. The “LOW” matching network has proven to be more suitable compared to the “HIGH” network as it exhibits better performance with lower input powers: 30 % efficiency (Fig. 5) and a 10 s (Fig. 6) wake-up time at -10 dBm. This allows for a quick system startup, as in the case of a completely discharged storage capacity (i.e., in the worst case), the power harvesting system would only take 10 s to recharge it and power the rest of the system (tag and MCU). It is a key aspect for ensuring real-time monitoring. Another crucial aspect is that Rx antennas could potentially have any spatial orientation, mostly not fixed but depending on the use of the PPE. The tests with antennas have highlighted that to ensure power supply in various spatial orientations, the best solution lies with circularly polarized antennas for Tx and linearly polarized antennas for Rx. The results (Fig. 7) show more uniform and lower wake-up times than linear-linear coupling. The smart PPE must ensure sufficiently low power consumption so as not to drain storage capacity during capacitive measurement. The energy consumed by the smart PPE is obtained from the integral of the current consumption (Fig. 9) and multiplied by the supply voltage (1.8 V), which is
Finally, the proof-of-concept of the smart PPE was validated with a test bench simulating a realistic condition. This test compared two flexible antennas (Armata SRFC011 and Montana SRF2I019) mounted on the power harvester. The results (Fig. 10) show that the Armata SRFC011 antenna outperforms the Montana SRF2I019 antenna, ensuring proper functionality (power supply and data exchange) up to a distance of 4 m. The best results were obtained up to a distance of 2 m. While for longer distances 3 m to 4 m, the system continues to operate, facilitating data exchange; however, the results also highlight increased variability. This behavior stems from the fact that at distances of 3 m to 4 m, the input power to the smart PPE may not always be sufficient to maintain device operation. Consequently, the device may not be adequately powered, causing the power harvester to temporarily disconnect the power supply to the MCU and the tag. One possible solution is to increase the time between measurements to allow proper charging of the storage capacitor. Also, the reader configuration with only one antenna was used in the measurement setup, but extending its operation to 4 antennas is possible, ensuring greater spatial coverage.
Table 3 compares this work concerning the state-of-the-art smart devices for PPE and industry safety. The table shows different solutions using primary or secondary power systems and active or passive transmission systems. Our system, as well as the one in [40], compared to the state-of-the-art, presents a solution that leverages the same energy source for both powering and data communication, ensuring better compactness by avoiding the use of a primary power source (battery) [10], [11], [13], [39] and enabling potential system miniaturization on flexible substrates. Battery-powered systems require continuous maintenance due to replacement or recharging of the batteries themselves, unlike systems using secondary power that are immediately ready for use. The reported battery lifespan in [13] and [39] are 10 h and 384 h, respectively. In contrast, systems that use a secondary power system are immune to this issue by ensuring immediate use and an infinite device lifetime. Batteries can overheat or short-circuit, especially if damaged or misused, thus increasing the risk of serious accidents, especially in sensitive or hazardous work environments. The proposed system guarantees power consumption at least three orders of magnitude lower than those reported in [12], [13], and [14] and an order of magnitude lower compared to the system in [40]. The key advantage of using a single capacitive sensor and backscattering as the communication method is the reduction in power consumption while still ensuring the monitoring of proper PPE usage. Furthermore, compared to systems powered by a secondary power source [12], [14], the storage capacity is significantly lower, further enabling improved system miniaturization. A key aspect of the proposed system is to provide greater spatial coverage. The systems presented in [13] and [14] have significantly greater coverage because they use an active transmission method; on the other hand, the power consumption is significantly higher, thus having to rely on either a primary power system or a secondary power system and big supercapacitor, making the systems impractical to the wearable. In comparison, the system presented in [40], albeit with similar characteristics, shows an operational range smaller by almost a factor of 3 with a single transmitter antenna and the same output power equal to 30 dBm. Specifically, our system can support smart PPE up to 4 m, whereas the maximum distance in [40] is limited to 1.5 m. Extending the reader’s operation to utilize multiple antennas could enhance spatial coverage. In [40], it is estimated that by using more readers, it is possible to extend the coverage range up to 50 m.
The potential of our system is the realization of a ULP wearable system that can be easily integrated into the industrial infrastructure and miniaturized, which can, at the same time, improve workplace safety by actively monitoring the proper use of PPE in real time.
Conclusion
In this work, the proof-of-concept of a smart PPE has been introduced. The system allows for real-time monitoring of whether the PPE is worn correctly by the worker, ensuring enhanced industrial safety, ease of integration, and miniaturization. Compared to the state-of-the-art, this system reduces power consumption by at least three orders of magnitude and leverages simultaneous wireless information and power transfer. The proposed system offers numerous advantages, including increased safety in hazardous environments, greater adherence to safety protocols, and the potential to prevent accidents and injuries. Real-time monitoring facilitates timely interventions and corrective measures promoting a safer work environment. In future work, we will focus on the miniaturization of the system to integrate it into flexible substrates, enhancing its versatility and adaptability. We also envision implementing multiple transmitting TX antennas to enhance the system’s spatial coverage, track the status of PPE, and localize the position within the workplace. In addition, the experimental tests will be extended in real scenarios of work environments, allowing for a comprehensive assessment of its effectiveness and reliability.