Abstract:

The demand for an efficient and reliable ultrasonic phased array imaging system is not unique to a single industry. Today’s imaging systems can be enhanced in a number of...Show More

Abstract:

The demand for an efficient and reliable ultrasonic phased array imaging system is not unique to a single industry. Today’s imaging systems can be enhanced in a number of areas including; improving scanning and processing times, reducing data storage requirements, simplifying hardware, and prolonging probe lifespan. In this work, it is shown that by combining the use of coded excitation with single-bit data capture, a number of these areas can be improved. Despite using single-bit receive data, resolution can be recovered through the coded excitation pulse compression process, and shown to produce high signal-to-noise ratio (SNR) images of phase coherence imaging (PCI) and total focusing method (TFM) of tip diffraction in a carbon steel sample. Comparison with conventional single-cycle transmission pulses has shown that little imaging performance degradation is seen despite a significant reduction in data resolution and size. This has also been shown to be effective at low excitation voltages with gain compensation due to the obsolescence of signal saturation concerns when considering single-bit receive data. The ability to compute high-resolution ultrasonic images from low-resolution input data at low transmission voltages has important implications for data compression, acquisition and imaging performance, operator safety, and hardware simplification for ultrasonic imaging systems across industrial and medical fields.
Page(s): 1120 - 1131
Date of Publication: 15 May 2024

ISSN Information:

PubMed ID: 38748526

Funding Agency:

References is not available for this document.

I. Introduction

The ability to determine the internal features and integrity of a subject nondestructively is a crucial process across countless industrial and medical industries. A number of methods are widely used and available, each providing unique advantages for specific applications.

Select All
1.
W. Gebhardt, "Improvement of ultrasonic testing by phased arrays", Nucl. Eng. Design, vol. 76, no. 3, pp. 275-283, Dec. 1983.
2.
B. W. Drinkwater and P. D. Wilcox, "Ultrasonic arrays for non-destructive evaluation: A review", NDT E Int., vol. 39, no. 7, pp. 525-541, Oct. 2006.
3.
J. Zhang, B. W. Drinkwater and P. D. Wilcox, "Comparison of ultrasonic array imaging algorithms for nondestructive evaluation", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 60, no. 8, pp. 1732-1745, Aug. 2013.
4.
C. Holmes, B. Drinkwater and P. Wilcox, "The post-processing of ultrasonic array data using the total focusing method", Insight Non-Destructive Test. Condition Monitor., vol. 46, no. 11, pp. 677-680, Nov. 2004.
5.
C. Holmes, B. W. Drinkwater and P. D. Wilcox, "Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation", NDT E Int., vol. 38, no. 8, pp. 701-711, Dec. 2005.
6.
J. Camacho, M. Parrilla and C. Fritsch, "Phase coherence imaging", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 5, pp. 958-974, May 2009.
7.
N. Portzgen, D. Gisolf and G. Blacquiere, "Inverse wave field extrapolation: A different NDI approach to imaging defects", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 1, pp. 118-127, Jan. 2007.
8.
A. J. Hunter, B. W. Drinkwater and P. D. Wilcox, "The wavenumber algorithm for full-matrix imaging using an ultrasonic array", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 55, no. 11, pp. 2450-2462, Nov. 2008.
9.
J. Zhang, B. W. Drinkwater, P. D. Wilcox and A. J. Hunter, "Defect detection using ultrasonic arrays: The multi-mode total focusing method", NDT E Int., vol. 43, no. 2, pp. 123-133, Mar. 2010.
10.
P. D. Wilcox, C. Holmes and B. W. Drinkwater, "Advanced reflector characterization with ultrasonic phased arrays in NDE applications", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 8, pp. 1541-1550, Aug. 2007.
11.
J. F. Cruza, J. Camacho and C. Fritsch, "Plane-wave phase-coherence imaging for NDE", NDT E Int., vol. 87, pp. 31-37, Apr. 2017.
12.
J. Camacho, D. Atehortua, J. F. Cruza, J. Brizuela and J. Ealo, "Ultrasonic crack evaluation by phase coherence processing and TFM and its application to online monitoring in fatigue tests", NDT E Int., vol. 93, pp. 164-174, Jan. 2018.
13.
B. Gauthier, G. Painchaud-April, A. Le Duff and P. Bélanger, "Towards an alternative to time of flight diffraction using instantaneous phase coherence imaging for characterization of crack-like defects", Sensors, vol. 21, no. 3, pp. 730, Jan. 2021.
14.
Y. Javadi et al., "Continuous monitoring of an intentionally-manufactured crack using an automated welding and in-process inspection system", Mater. Design, vol. 191, Jun. 2020.
15.
Y. Javadi et al., "High-temperature in-process inspection followed by 96-h robotic inspection of intentionally manufactured hydrogen crack in multi-pass robotic welding", Int. J. Pressure Vessels Piping, vol. 189, Feb. 2021.
16.
D. G. Aggelis and A. S. Paipetis, "Monitoring of resin curing and hardening by ultrasound", Construct. Building Mater., vol. 26, no. 1, pp. 755-760, Jan. 2012.
17.
C. Holmes, B. W. Drinkwater and P. D. Wilcox, "Advanced post-processing for scanned ultrasonic arrays: Application to defect detection and classification in non-destructive evaluation", Ultrasonics, vol. 48, no. 6, pp. 636-642, Nov. 2008.
18.
D. I. A. Lines, "Rapid distributed data collection with arrays—The next step beyond full waveform capture", Insight Non-Destructive Test. Condition Monitor., vol. 48, no. 2, pp. 84-88, Feb. 2006.
19.
M. Fornasier and H. Rauhut, "Compressive sensing" in Handbook of Mathematical Methods in Imaging, New York, NY, USA:Springer, pp. 187-228, 2011.
20.
Z. Bai, S. Chen, Q. Xiao, L. Jia, Y. Zhao and Z. Zeng, "Compressive sensing of phased array ultrasonic signal in defect detection: Simulation study and experimental verification", Struct. Health Monitor., vol. 17, no. 3, pp. 434-449, May 2018.
21.
P. Yang, B. Chen and K.-R. Shi, "A novel method to design sparse linear arrays for ultrasonic phased array", Ultrasonics, vol. 44, pp. e717-e721, Dec. 2006.
22.
L. Moreau, B. W. Drinkwater and P. D. Wilcox, "Ultrasonic imaging algorithms with limited transmission cycles for rapid nondestructive evaluation", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 9, pp. 1932-1944, Sep. 2009.
23.
A. Austeng and S. Holm, "Sparse 2-D arrays for 3-D phased array imaging–design methods", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 49, no. 8, pp. 1073-1086, Aug. 2002.
24.
Y. Lu, R. Demirli, G. Cardoso and J. Saniie, "A successive parameter estimation algorithm for chirplet signal decomposition", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 11, pp. 2121-2131, Nov. 2006.
25.
Y. Nabil, B. Toufik and G. Morad, "Ultrasonic signals parameters estimation based on differential evolution", Proc. 3rd Int. Conf. Control Eng. Inf. Technol. (CEIT), pp. 1-5, May 2015.
26.
G. Cardoso and J. Saniie, "Performance evaluation of DWT DCT and WHT for compression of ultrasonic signals", Proc. IEEE Ultrason. Symp., pp. 2314-2317, Aug. 2004.
27.
B. Gauthier, G. Painchaud-April, A. L. Duff and P. Belanger, "Lightweight and amplitude-free ultrasonic imaging using single-bit digitization and instantaneous phase coherence", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 69, no. 5, pp. 1763-1774, May 2022.
28.
L. J. Cunningham, A. J. Mulholland, K. M. M. Tant, A. Gachagan, G. Harvey and C. Bird, "The detection of flaws in austenitic welds using the decomposition of the time-reversal operator", Proc. Roy. Soc. A Math. Phys. Eng. Sci., vol. 472, no. 2188, Apr. 2016.
29.
R. Y. Chiao and X. Hao, "Coded excitation for diagnostic ultrasound: A system developer’s perspective", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, no. 2, pp. 160-170, Feb. 2005.
30.
S. Zhou, X. Wang, Q. Ye, J. Yang, J. Ji and Y. Wang, "Medical high-frequency ultrasound imaging using Golay-coded pulse excitation", Proc. 5th Int. Conf. Biomed. Eng. Informat., pp. 71-75, Oct. 2012.