I. Introduction
Cascade systems, assembled from MCGs, in which each preceding generator is a power source for the next one are used to decrease weight and size of initial power source of magneto-cumulative generators (MCG) [1]–[3]. It is better to form this system based on helical MCGs, having high magnetic energy gain, combined by usual cylindrical step-up transformers [2]. These transformers are small and allow to power high-impedance loads.