Seaports play a crucial role in global trade, acting as key hubs in international logistics networks. However, the growth of maritime activities has led to significant environmental challenges, including elevated carbon emissions and pollution. This paper presents an in-depth bibliometric analysis of sustainable and smart port initiatives, utilizing data from the Web of Science database to identif...Show More
Intelligent lighting systems use various methodologies comprising both standard protocols, intelligent methods, control systems, and sensors. These protocols define the communication among lighting devices and control systems, and many open standards allow interoperability among products from different manufacturers. They offer flexibility and a wide simplified selection in updates and implementat...Show More
The IEEE1584-2018 guide is the universally recognized method to evaluate the arc-flash phenomenon. Previous works introduced the Parise model, a simplified approach that outlines the behavior of the arcing fault current as an extension of the bolted fault analysis highlighting that in a.c. a necessary parameter is the power factor PF of the bolted short-circuit. This method considers values in p.u...Show More
Energy and environmental planning of port systems must define specific strategies and implementation measures to improve energy efficiency. They must provide innovative solutions and short, medium and long-term requalification. Sustainability criteria must be aimed at converting all port equipment to zero emissions promoting the use of renewable energy. A guideline for the master plan of port syst...Show More
The primary objective of the technological systems tunnel project is to ensure the normal functioning, avoid accidents and moderate their effects for the safety of users. The systems availability is therefore essential for which they must guarantee their operation when necessary and required. The article deals with the design criteria to ensure their service continuity with a comb configuration of...Show More
The increase in greenhouse gas emissions (GHG) from the transportation sector, along with the ongoing depletion of fossil fuels, emphasizes the necessity for increased focus on energy storage systems (ESSs) and renewable energy sources (RESs) in seaports and on short-distance vessels such as ferries. This paper investigates the development of next-generation smart ports, wherein the integration of...Show More
The maritime sector is experiencing significant change, creating challenges and opportunities for seaports. This review explores the evolving landscape of seaports by analyzing various academic papers, providing a roadmap for understanding their changing nature. This paper examines the historical development of seaports, focusing on the latest fifth generation, emphasizing sustainability, intellig...Show More
The design of an electrical system is permanent and a complex process that must follow the system throughout its complete life. All system components, from the installation and commissioning, are subject to a natural degradation which will lead to deterioration of the electrical and mechanical properties, leading to the end of its life. Therefore, the electrical system, to guarantee a "nominal" pe...Show More
A guideline for the port system master plan must provide innovative and redevelopment solutions in short, medium and long-term energy planning. It can contribute in the competitiveness competition of its geographical sector to the pursuit of objectives of high performance, functionality, service continuity (Business Continuity) and eco-sustainability. The provision of organizational procedures and...Show More
Power systems in road tunnels must guarantee the “critical state for the safety of human life” in the event of a fire and must ensure its service continuity. This article deals with the several problems that jet fan operation presents, such as the high inrush and re-inrush currents in direct starting, and the admissible transient voltage drops. Then, it highlights measures to make more effective t...Show More
The service continuity of the electrical systems is a fundamental objective for the safety of users in road tunnels, because it assists to prevent accidents and to mitigate their consequences. The black hole effect in the tunnel access area can cause accidents, therefore a support lighting is provided to ensure the perception of any obstacles. In case of fire events, the safety lighting system is ...Show More
This paper presents a generalized model of the arcing fault circuit in a.c. extendable to d.c., that consents to identify the arc resistance operating in the fault. This model allows to describe completely the trend of all the prospected parameters of interest in a normalized form in relation to the bolted short circuit current and the apparent power related to it. The adoption of the arc fault cu...Show More
Maritime industry has experienced substantial progress with impressive technological advancements in recent decades. However, this growth has also created new challenges that threaten the industry. This paper reviews the state-of-the-art of the next-generation smart ports, focusing on seaport microgrids with hierarchical control strategies. Additionally, the next-generation port's digitalized arch...Show More
This paper aims to identify the essential purposes for smart lighting development including areas of application, methodologies, objectives, potential disruptions, and ethical considerations. Smart lighting can enhance citizens' quality of life and ensure safety in outdoor environments. Lighting is a critical factor in sustainable development, and the convergence of lighting and ICT industries is ...Show More
This paper presents the design criteria for electrical systems in road tunnels to guarantee the operational continuity of the safety and other services in the event of a road accident, with or without the development of a fire. Two essential criteria are based on the module and zoning of the road tunnels which allow for a configuration of the supply systems as a special comb system. This structure...Show More
For road tunnels. the design criteria of the power systems, based on the partition in modules and zoning, must ensure the service continuity and safeguard the “critical state for the safety of human life” in the event of a fire. This paper deals with the various problems that jet fans operation presents such as the high inrush and re-inrush currents in direct starting, the admissible transient vol...Show More
This paper introduces a simplified calculation of the arc fault current as an update of the method, previously proposed by the authors, as a complement to the IEEE 1584-2018 guideline method, for calculating the incident energy and arc flash limit. The approximate calculation proposed introduces factors and equations that lead to results that are completely comparable with those obtained with the ...Show More
Lightning strikes can cause physical harm to people and damage inside commercial, industrial, and residential structures. The risk of damage from lightning depends on the dimensional and environmental characteristics of the structure, the number of people and their permanence in the structure, their reaction to a possible fire, and the density of lightning strikes to the ground in the structure lo...Show More
The protection system for the structures against lightning is basically constituted by means of an air termination system, down-conductors and a ground-termination system. The IEC standard 62305 introduces the rolling sphere method to analyze and to design the protected volumes of air-termination systems with a complex configuration. In order to avoid the exposure of equipment and elements on the ...Show More
This paper upgrades a method, proposed to calculate the incident energy and the arc-flash boundary in a previous paper, and introduces a simplified calculation of the arc fault current. The approximated method, proposed as complementary to the method of the IEEE 1584–2018 guide, aims to have a physical understanding of the phenomenon and adopts factors to analyze singularly the various parameters ...Show More
This paper is intended as a first basic document of a more general white paper on smart lighting. Distributed Artificial Lighting systems penetrate into the internal and external human environment in a complete osmosis and with their smart interactive function practically become an all-seeing eye, a “big eye”, of human activities. Smart lighting indoor and more especially outdoor constitutes a mes...Show More
The electrical power required in an electrified car park can be significant, so it appears necessary a rational design of the distribution system for the recharging sockets, in order to obtain an expandable and cost-effective system. This paper deals with the designing criteria to electrify an EV park suggesting a load-driven approach. The modularity of the configuration allows for easier manageme...Show More
Lightning flashes to ground may cause injury to persons and damages inside of commercial, industrial and residential structures. The lightning risk depends on the dimensional and environmental characteristics of the structure as well as on lightning ground flash density in its location. The prospected risk can determine the need of protection measures. The standard IEC 62305–2 proposes a method to...Show More
The IEC standard series 62305 presents basic requirements for the lightning protection design of structures. In determining the position of the air-termination system, two methods are generally suggested: the protective angle method and the rolling sphere method. Adopting a 3-D graphical simulation, the “rolling sphere” method allows one: to analyze the protected volume at the building roof inside...Show More
This article presents the calculation procedure of short circuits adopting the characteristic currents method (CCM). In a previous paper by the author G. Parise, the CCM has been upgraded with the introduction of “characteristic” countercurrents and the generalization of the Kirchhoff laws. For illustrating the calculation procedure, the selected case study deals with a low voltage cold ironing sy...Show More