The fault current signal measured by digital relays contains the decaying direct-current (DDC) component and some higher-order harmonics in addition to the fundamental component. One important challenge of phasor estimation algorithms is the removal of the DDC component, as the presence of this component causes errors in the estimation of the fundamental component magnitude, which can result in ma...Show More
The ultimate goal of power transformer protection system is to quickly and reliably detect internal faults while remaining stable for external faults and transients. Since in the conventional protection system, each relay decides about the transformer condition independently, it can be considered that the output signals of relays are logically “OR”ed with each other. In this case, confirming inter...Show More
Power transformers are of the most critical and expensive equipment in the power system industry. Meanwhile, they are exposed to a variety of faulty and abnormal operating conditions. Therefore, to prevent extension of these events they are protected by different protective schemes. Among the various types of the transformer faults, detecting turn-to-turn faults is the most challenging one for the...Show More
Online continuous monitoring of dissolved gasses in transformer oil has become an emerging trend in the recent years. This way, in addition to sending the warning signal in the case of gas concentration, a fault diagnosis procedure can be conducted using standard Dissolved Gas Analysis (DGA) methods. However, since the fault diagnosis outcome and result of these methods are sometimes different, an...Show More
This article presents a novel straightforward and real-time algorithm to measure power system frequency. The main idea of this approach is to improve accuracy of the estimated frequency during off-nominal frequency conditions. The proposed approach includes two stages: 1) the DFT algorithm is used to estimate voltage amplitude and phase angle by assuming that the frequency is the same as its value...Show More
This paper proposes a novel fast and accurate method to mitigate the decaying DC (DDC) component from the fault current signal. At the first stage, it starts to identify the DDC parameters by integrating six sub-cycle samples of current signal considering the symmetry feature of odd harmonics. By receiving the next samples, the estimation of DDC parameters is updated and improved. This procedure c...Show More
Single-phase auto-reclosing (AR) scheme is widely employed in extra high voltage (EHV) transmission networks to quench transient faults without completely removing the faulted transmission line (TL). Long EHV TLs are commonly equipped with shunt reactors to reduce the Ferranti effect overvoltages. It is common practice to disconnect these reactors under the heavy load periods during the year. Cons...Show More