Loading [MathJax]/extensions/MathZoom.js
IEEE Xplore Search Results

Showing 1-25 of 5,195 resultsfor

Filter Results

Show

Results

This paper presents a novel calibration algorithm using unknown line-series-shunt standards that are suitable for planar transmission line structures for the broadband S-parameter measurements of microwave vector network analyzers. The derivations are based on the eight-term error model with the matched line standard and the lumped assumptions for the series and shunt calibration kits, respectivel...Show More
We present an improved coaxial multiline through-reflect-line calibration method which allows to correct for errors in the description of calibration standards. Our approach is based on the multi-frequency formulation of the vector-network-analyzer calibration problem which accounts for the physical relationships between calibration standard S-parameters at different frequencies. We illustrate our...Show More
In this paper, a numerical short-open calibration (SOC) method is presented to numerically deembed the complex propagation constant of half-mode substrate integrated waveguide (HMSIW). After three distinctive equivalent circuit networks are described for SOC deembedding procedures, the propagation characteristics of HMSIW can be extracted. The numerical stability and convergence are illustrated. T...Show More
Offset short calibration schemes for vector network analyzers require the exact knowledge of the propagation constant of the offsetting lines. The propagation constant is difficult to compute from first principles and thus a method to indirectly determine the propagation constant is presented. At 50 GHz, the method achieves improvements of accuracy of at least 0.013 in linear S-parameters for a 2....Show More
Two spaceborne instruments share the scientific objective of mapping the global Sea Surface Salinity (SSS). ESA's Soil Moisture and Ocean Salinity (SMOS) and NASA's Aquarius use L-band (1.4 GHz) radiometry to retrieve SSS. We find that SSS retrieved by SMOS is generally lower than SSS retrieved by Aquarius, except for very cold waters where SMOS SSS is higher overall. The spatial distribution of t...Show More
A novel broadband non-resonant Thru-Line (TL) technique is proposed for the extraction of substrate complex permittivity, while the influence of the end-launch connectors is fully suppressed. The main difference to the traditional TRL techniques is that only two calibration standards are needed and the length difference between Thru and Line is much larger than a quarter of a wavelength at the cen...Show More
Electromagnetic modeling of coaxial 1:85mm and 1:0mm standards for Vector Network Analyzer (VNA) calibration shows only limited accuracy. The approach presented in this paper can overcome this accuracy limitation. Instead of handing over the standards’ S-parameters to the calibration algorithm, parameterized models of the standards are used as input into the calibration algorithm. The technique is...Show More
Propagation constant characterization plays a key role in various microwave measurement situations such as thru-reflect-line (TRL) calibration, interconnect characterization, fixture de-embedding and measurement of material properties. To differentiate the forward and backward propagating factors, sign-ambiguity problem of square-root searching is inevitable in the process of characterizing the ei...Show More
In this paper, a simple method of extracting dielectric material is proposed and copper surface roughness is taken into consideration. The measured results from W-band to D-band are shown to verify the proposed method of extracting complex permittivity of dielectrics. Besides, to validate the proposed transmission line technique, the full sets of complex S-parameters with an appropriate “through-r...Show More
Measurements of the complex dielectric constant of seawater at 30.00 psu, 35.00 psu and 38.27 psu over the temperature range from 5degC to 35degC at 1.413 GHz are given and compared with the Klein-Swift results. A resonant cavity technique is used. The calibration constant used in the cavity perturbation formulas is determined experimentally using methanol and ethanediol (ethylene gycol) as refere...Show More
Calibration of the spring constants of atomic force microscopy (AFM) cantilevers is one of the issues in biomechanics and nanomechanics for quantified force metrology at pico- or nano Newton level. In this paper, we present an AFM cantilever calibration system: the Nano Force Calibrator (NFC), which consists of a precision balance and a one-dimensional stage. Three types of AFM cantilevers (contac...Show More
The calibration and de-embedding outcomes of utilizing different liquid combinations as standards are studied. Using standards with significant disparities aids in minimizing calibration errors, whereas employing standards with similar liquid dielectric constants creates significant calibration discrepancies. Optimal calibration liquids consist of a high permittivity liquid, a low permittivity liq...Show More
This paper presents a simple, lightweight, automatic calibration method for low-cost triaxial accelerometers, utilizing the Earth’s gravitational constant in various orientations. It can be easily implemented using only fixed-point arithmetic and can run on low-power microcontrollers for real-time measurements, making it practical for scenarios with limited data storage and computational power, su...Show More
The through–line calibration family uses measurements of a through connection and an inserted line to determine the propagation constant of the line. This is typically used with measurements of a reflect standard to characterize fixturing errors. Subsequently, the S-parameters of a device under test are de-embedded. Measurement uncertainties occur at frequencies where the length of the line standa...Show More
We present, for the first time, the utility of Thru-Reflect-Line (TRL) calibration up to 100GHz on millimeter-wave printed circuit boards using next-generation WSMP connectors. A coplanar waveguide (CPW) TRL calibration kit is fabricated on Isola Astra MT77 substrate and raw measurements for 2-port scattering parameters of the calibration standards are recorded in two overlapping bands using two s...Show More
This study reformulated the eigenvalue problems associated with the thru-reflect-line (TRL)/line-reflect-line (LRL) calibration and other related applications without presuming that the line standards or test lines are reciprocal or symmetrical and that they have identical transitions explicitly defined by fixed physical reference planes. The new formulation, therefore, can identify the components...Show More
Integrated planar technique has always been considered as a reliable candidate for low-cost mass production of millimeter-wave circuits and systems. In this paper, a numerical multimode calibration procedure is proposed and developed with a commercial software package on the basis of a full-ware finite element method (FEM) for the accurate extraction of complex propagation constants of substrate i...Show More
This paper presents an alternative method for a network analyzer calibration, in particular an in-fixture calibration. It avoids de-embedding of the device under test and it allows the characterization of an unknown two-port inserted between an arbitrary number of cascaded unknown two-ports. An unknown obstacle must be moved on a transmission line into three positions. The LNN calibration techniqu...Show More
In this paper, the complex propagation constant of grounded coplanar waveguide (GCPW) is extracted by the multiline method, as well as the thru-line method, over a wide frequency range. The effects of port discontinuities and feeding network are de-embedded successfully. Base on the results, the propagation characteristics of the finite grounds conductor backed CPW (FGCBCPW) and GCPW are compared....Show More
In this paper, a dielectric constant measurement system is presented, which can work at different temperatures from room temperature to 200°C. This system is developed based on the theory of NRW algorithm using coaxial line. The calibration standards are also designed for TRL calibration. Temperature distribution is analyzed and optimized carefully using ANSYS thermal analysis to make sure tempera...Show More
An external calibration experiment was held for an airborne SAR. The paper describes the calibration experiment that uses a series of trihedral corner reflectors to calibrate the high-resolution SAR images, including antenna pattern correction and absolute radiometric calibration. In this paper, we specifically address the determination of vertical antenna pattern with multi-flight SAR imaging geo...Show More
This paper presents a useful low-cost wideband dielectric characterization technique for packaging substrates using a coaxial air line technique up to 67 GHz. To the authors' knowledge, this is the first demonstration of dielectric properties up to 67 GHz using coaxial air lines. The proposed method to extract the material properties is reference-plane-invariant (RPI) which combines Nicolson-Ross-...Show More
SAR calibration is one of the most important technique of measurable observation and to calibrate SAR images to normalized radar cross sections (NRCS) a calibration constant is required. Usually the calibration constant is determined by analyzing measurements of corner reflectors or transponders. However, for Global Monitoring mode of ASAR, we can not facture so large radar cross section (RCS) cal...Show More
MIL-STD-461 has been applied and adapted as the basis for electromagnetic interference standards in many countries. By investigating the different versions of MIL-STD-461/462 in this paper, it can be found that the requirement and procedure of system calibration of RS105 test are more and more specific and comprehensive. Some problems are also discussed subsequently in the application of the calib...Show More
In this paper, a corrugated substrate integrated waveguide (CSIW) with no metallic vias is proposed, and its propagation characteristics are investigated via our numerical SOC de-embedding method. In our analysis, dominant operating modes in this CSIW at different frequencies are extensively discussed. In final, its complex propagation constant, i.e., phase and attenuation constants, is derived to...Show More